Preclinical evaluation of the versius surgical system, a new robot-assisted surgical device for use in minimal access general and colorectal procedures

被引:45
作者
Morton, Jonathan [1 ]
Hardwick, Richard H. [1 ]
Tilney, Henry S. [2 ]
Gudgeon, A. Mark [2 ]
Jah, Asif [3 ]
Stevens, Lewis [4 ]
Marecik, Slawomir [5 ,6 ]
Slack, Mark [7 ]
机构
[1] Cambridge Univ Hosp NHS Fdn Trust, Addenbrookes Hosp, Dept Gastrointestinal Surg, Cambridge, England
[2] Frimley Hlth NHS Fdn Trust, Dept Surg, Frimley Pk Hosp, Surrey, England
[3] Cambridge Univ Hosp NHS Fdn Trust, Addenbrookes Hosp, Cambridge HepatoPancreato Biliary & Transplant Ct, Cambridge, England
[4] Queen Mary Univ London, Barts Canc Inst, Dept Mol Oncol, London, England
[5] Advocate Lutheran Gen Hosp, Div Colon & Rectal Surg, Chicago, IL USA
[6] Univ Illinois, Chicago, IL 60680 USA
[7] CMR Surg Ltd, 1 Evolut Business Pk,Milton Rd, Cambridge CB24 9NG, England
来源
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES | 2021年 / 35卷 / 05期
关键词
Minimally invasive surgical procedures; Robotic surgical procedures; General surgery; Colorectal surgery; SURGERY;
D O I
10.1007/s00464-020-07622-4
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective To evaluate the utility of a new robot-assisted surgical system (the Versius Surgical System, CMR Surgical, Cambridge, UK) for use in minimal access general and colorectal surgery, in a preclinical setting. Summary background data Robot-assisted laparoscopy has been developed to overcome some of the important limitations of conventional laparoscopy. The new system is designed to assist surgeons in performing minimal access surgery and overcome some of the challenges associated with currently available surgical robots. Methods Cadaveric sessions were conducted to evaluate the ability of the system to provide adequate surgical access and reach required to complete a range of general and colorectal procedures. Port and bedside unit positions were recorded, and surgical access and reach were evaluated by the lead surgeon using a visual analogue scale. A live animal (porcine) model was used to assess the surgical device's safety in performing cholecystectomy or small bowel enterotomy. Results Nine types of procedure were performed in cadavers by nine lead surgeons; 35/38 procedures were completed successfully. The positioning of ports and bedside units reflected the lead surgeons' preferred laparoscopic set-up and enabled good surgical access and reach. Cholecystectomy (n = 6) and small bowel enterotomy (n = 5) procedures performed in pigs were all completed successfully by two surgeons. There were no device-related intra-operative complications. Conclusions This preclinical study of a new robot-assisted surgical system for minimal access general and colorectal surgery demonstrated the safety and effectiveness of the system in cadaver and porcine models. Further studies are required to assess its clinical utility.
引用
收藏
页码:2169 / 2177
页数:9
相关论文
共 18 条
  • [1] Re-appraisal and consideration of minimally invasive surgery in colorectal cancer
    Abu Gazala, Mahmoud
    Wexner, Steven D.
    [J]. GASTROENTEROLOGY REPORT, 2017, 5 (01): : 1 - 10
  • [2] Assessment of the Versius surgical robotic system for dual-field synchronous transanal total mesorectal excision (taTME) in a preclinical model: will tomorrow's surgical robots promise newfound options?
    Atallah, S.
    Parra-Davila, E.
    Melani, A. G. F.
    [J]. TECHNIQUES IN COLOPROCTOLOGY, 2019, 23 (05) : 471 - 477
  • [3] Who did the first laparoscopic cholecystectomy
    Blum, Craig A.
    Adams, David B.
    [J]. JOURNAL OF MINIMAL ACCESS SURGERY, 2011, 7 (03) : 165 - 168
  • [4] Laparoscopic surgery for rectal cancer
    Chand, Manish
    Bhoday, Jemma
    Brown, Gina
    Moran, Brendan
    Parvaiz, Amjad
    [J]. JOURNAL OF THE ROYAL SOCIETY OF MEDICINE, 2012, 105 (10) : 429 - 435
  • [5] Robotics in general surgery - Personal experience in a large community hospital
    Giulianotti, PC
    Coratti, A
    Angelini, M
    Sbrana, F
    Cecconi, S
    Balestracci, T
    Caravaglios, G
    [J]. ARCHIVES OF SURGERY, 2003, 138 (07) : 777 - 784
  • [6] Haig F, 2019, BMJ SURG INTERVENT H
  • [7] Using end-user feedback to optimize the design of the Versius Surgical System, a new robot-assisted device for use in minimal access surgery
    Hares, Luke
    Roberts, Paul
    Marshall, Keith
    Slack, Mark
    [J]. BMJ SURGERY INTERVENTIONS & HEALTH TECHNOLOGIES, 2019, 1 (01)
  • [8] No Surgical Innovation Without Evaluation Evolution and Further Development of the IDEAL Framework and Recommendations
    Hirst, Allison
    Philippou, Yiannis
    Blazeby, Jane
    Campbell, Bruce
    Campbell, Marion
    Feinberg, Joshua
    Rovers, Maroeska
    Blencowe, Natalie
    Pennell, Christopher
    Quinn, Tom
    Rogers, Wendy
    Cook, Jonathan
    Kolias, Angelos G.
    Agha, Riaz
    Dahm, Philipp
    Sedrakyan, Art
    McCulloch, Peter
    [J]. ANNALS OF SURGERY, 2019, 269 (02) : 211 - 220
  • [9] Robotic-assisted total mesorectal excision with the single-docking technique for patients with rectal cancer
    Huang, Ching-Wen
    Tsai, Hsiang-Lin
    Yeh, Yung-Sung
    Su, Wei-Chih
    Huang, Ming-Yii
    Huang, Chun-Ming
    Chang, Yu-Tang
    Wang, Jaw-Yuan
    [J]. BMC SURGERY, 2017, 17
  • [10] Jayaraman S, 2009, CAN J SURG, V52, P374