The efficacy and safety of mechanical hemodynamic support in patients undergoing high-risk percutaneous coronary intervention with or without cardiogenic shock: Bayesian approach network meta-analysis of 13 randomized controlled trials

被引:18
作者
Lee, Joo Myung [1 ,2 ]
Park, Jonghanne [1 ,2 ]
Kang, Jeehoon [1 ,2 ]
Jeon, Ki-Hyun [1 ,2 ]
Jung, Ji-hyun [1 ,2 ]
Lee, Sang Eun [1 ,2 ]
Han, Jung-Kyu [1 ,2 ]
Kim, Hack-Lyoung [3 ,4 ]
Yang, Han-Mo [1 ,2 ]
Park, Kyung Woo [1 ,2 ]
Kang, Hyun-Jae [1 ,2 ]
Koo, Bon-Kwon [1 ,2 ]
Kim, Sang-Hyun [3 ,4 ]
Kim, Hyo-Soo [1 ,2 ,5 ]
机构
[1] Seoul Natl Univ Hosp, Dept Internal Med, Seoul 110744, South Korea
[2] Seoul Natl Univ Hosp, Ctr Cardiovasc, Seoul 110744, South Korea
[3] Seoul Natl Univ, Boramae Med Ctr, Dept Internal Med, Seoul, South Korea
[4] Seoul Natl Univ, Boramae Med Ctr, Ctr Cardiovasc, Seoul, South Korea
[5] Seoul Natl Univ, Mol Med & Biopharmaceut Sci, Grad Sch Convergence Sci & Technol, Seoul, South Korea
基金
新加坡国家研究基金会;
关键词
Aortic balloon pump; Left ventricular assist device; Primary PCI; Coronary intervention; INTRAAORTIC BALLOON COUNTERPULSATION; ACUTE MYOCARDIAL-INFARCTION; CLINICAL-TRIAL; ASSIST DEVICE; PUMP; MORTALITY; ANGIOPLASTY; GUIDELINES;
D O I
10.1016/j.ijcard.2015.01.081
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Studies have reported conflicting results regarding efficacy of mechanical hemodynamic support using intra-aortic balloon pump (IABP) or percutaneous ventricular assisted device (pVAD) in patients undergoing high-risk PCI. We performed a Bayesian network meta-analysis comparing the safety and efficacy of mechanical hemodynamic support devices and medical therapy (MT). Methods and results: RCTs comparing overall mortality of IABP versus MT or IABP versus pVAD in high-risk PCI populations were included. The primary endpoint was overall mortality, using the longest available follow-up in each study. This analysis included 2843 patients from 13 trials. In network meta-analysis, overall survival benefit was not significant with IABP (RR 0.84, 95% CrI 0.56-1.24) or pVAD (RR 0.95, 95% CrI 0.42-2.06), compared with MT. IABP or pVAD also did not show early survival benefit compared with MT. In terms of bleeding, pVAD was the worst (versus IABP: RR 29.4, 95% CrI 5.99-221.0; versus MT: RR 41.7, 95% CrI 8.19-330.0), which was mainly driven by the higher incidence of bleeding in the ECMO and TandemHeart, while IABP was worse than MT (RR 1.41, 95% CrI 1.01-2.08). The incidence of acute limb ischemia or vascular complication was not different between treatment groups. Conclusions: In this meta-analysis, routine elective use of IABP or pVAD did not reduce mortality, while it increased bleeding, compared with MT in high-risk PCI population or even in the patients with cardiogenic shock. Thoughtful selection of appropriate patients and balancing the risk and benefit should be the prerequisites to the use of mechanical hemodynamic support devices. (C) 2015 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:36 / 46
页数:11
相关论文
共 30 条
[1]   Improved outcome of cardiogenic shock at the acute stage of myocardial infarction: a report from the USIK 1995, USIC 2000, and FAST-MI French Nationwide Registries [J].
Aissaoui, Nadia ;
Puymirat, Etienne ;
Tabone, Xavier ;
Charbonnier, Bernard ;
Schiele, Francois ;
Lefevre, Thierry ;
Durand, Eric ;
Blanchard, Didier ;
Simon, Tabassome ;
Cambou, Jean-Pierre ;
Danchin, Nicolas .
EUROPEAN HEART JOURNAL, 2012, 33 (20) :2535-2543
[2]   2012 ACCF/AHA Focused Update Incorporated Into the ACCF/AHA 2007 Guidelines for the Management of Patients With Unstable Angina/Non-ST-Elevation Myocardial Infarction [J].
Anderson, Jeffrey L. ;
Adams, Cynthia D. ;
Antman, Elliott M. ;
Bridges, Charles R. ;
Califf, Robert M. ;
Casey, Donald E., Jr. ;
Chavey, William E., II ;
Fesmire, Francis M. ;
Hochman, Judith S. ;
Levin, Thomas N. ;
Lincoff, A. Michael ;
Peterson, Eric D. ;
Theroux, Pierre ;
Wenger, Nanette K. ;
Wright, R. Scott ;
Jneid, Hani ;
Anderson, Jeffrey L. ;
Wright, R. Scott ;
Adams, Cynthia D. ;
Bridges, Charles R. ;
Casey, Donald E., Jr. ;
Ettinger, Steven M. ;
Fesmire, Francis M. ;
Ganiats, Theodore G. ;
Lincoff, A. Michael ;
Peterson, Eric D. ;
Philippides, George J. ;
Theroux, Pierre ;
Wenger, Nanette K. ;
Anderson, Jeffrey L. ;
Jacobs, Alice K. ;
Halperin, Jonathan L. ;
Albert, Nancy M. ;
Creager, Mark A. ;
DeMets, David ;
Ettinger, Steven M. ;
Guyton, Robert A. ;
Hochman, Judith S. ;
Kushner, Frederick G. ;
Ohman, E. Magnus ;
Stevenson, William ;
Yancy, Clyde W. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 61 (23) :E179-E347
[3]   Short and long term effect of adjunctive intra-aortic balloon pump use for patients undergoing high risk reperfusion therapy: a meta-analysis of 10 international randomised trials [J].
Chen, Shaojie ;
Yin, Yuehui ;
Ling, Zhiyu ;
Krucoff, Mitchell W. .
HEART, 2014, 100 (04) :303-310
[4]   Percutaneous left ventricular assist devices vs. intra-aortic balloon pump counterpulsation for treatment of cardiogenic shock: a meta-analysis of controlled trials [J].
Cheng, Jin M. ;
den Uil, Corstiaan A. ;
Hoeks, Sanne E. ;
van der Ent, Martin ;
Jewbali, Lucia S. D. ;
van Domburg, Ron T. ;
Serruys, Patrick W. .
EUROPEAN HEART JOURNAL, 2009, 30 (17) :2102-2108
[5]   Intra-aortic balloon counterpulsation in US and non-US centres:: Results of the Benchmark® Registry [J].
Cohen, M ;
Urban, P ;
Christenson, JT ;
Joseph, DL ;
Freedman, RJ ;
Miller, MF ;
Ohman, EM ;
Reddy, RC ;
Stone, GW ;
Ferguson, JJ .
EUROPEAN HEART JOURNAL, 2003, 24 (19) :1763-1770
[6]   Cardiac power is the strongest hemodynamic correlate of mortality in cardiogenic shock: A report from the SHOCK trial registry [J].
Fincke, R ;
Hochman, JS ;
Lowe, AM ;
Menon, V ;
Slater, JN ;
Webb, JG ;
LeJemtel, TH ;
Cotter, G .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 44 (02) :340-348
[7]  
Gelman A., 1992, STAT SCI, V7, P457, DOI [DOI 10.1214/SS/1177011136, 10.1214/ss/1177011136]
[8]   Prophylactic intra-aortic balloon pump reduces C-reactive protein levels and early mortality in high-risk patients undergoing percutaneous coronary intervention [J].
Gu, Jun ;
Hu, Wei ;
Xiao, Hongbing ;
Feng, Xiaodi ;
Song, Zhiping ;
Chen, Yueguang ;
Zhang, Dadong .
ACTA CARDIOLOGICA, 2011, 66 (04) :499-504
[9]   Measuring inconsistency in meta-analyses [J].
Higgins, JPT ;
Thompson, SG ;
Deeks, JJ ;
Altman, DG .
BMJ-BRITISH MEDICAL JOURNAL, 2003, 327 (7414) :557-560
[10]   Assessing the quality of reports of randomized clinical trials: Is blinding necessary? [J].
Jadad, AR ;
Moore, RA ;
Carroll, D ;
Jenkinson, C ;
Reynolds, DJM ;
Gavaghan, DJ ;
McQuay, HJ .
CONTROLLED CLINICAL TRIALS, 1996, 17 (01) :1-12