Evaluation of the analytical performances of two Raman handheld spectrophotometers for pharmaceutical solid dosage form quantitation

被引:17
作者
Coic, Laureen [1 ]
Sacre, Pierre-Yves [1 ]
Dispas, Amandine [1 ,2 ]
Dumont, Elodie [1 ]
Horne, Julie [1 ]
De Bleye, Charlotte [1 ]
Fillet, Marianne [2 ]
Hubert, Philippe [1 ]
Ziemons, Eric [1 ]
机构
[1] Univ Liege ULiege, Lab Pharmaceut Analyt Chem, Vibra Sante Hub, CIRM, Ave Hippocrate 15, B-4000 Liege, Belgium
[2] Univ Liege ULiege, Lab Anal Med, MaS Sante Hub, CIRM, Ave Hippocrate 15, B-4000 Liege, Belgium
关键词
Raman handheld spectrophotometer; Quantitative performances; Accuracy profile method validation; Uniformity of dosage unit; Pharmaceutical tablets; NEAR-INFRARED SPECTROPHOTOMETER; FALSIFIED MEDICINES; QUALITY-CONTROL; VIBRATIONAL SPECTROSCOPY; NIRS;
D O I
10.1016/j.talanta.2020.120888
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper addresses the issue of pharmaceutical solid dosage form quantitation using handheld Raman spectrophotometers. The two spectrophotometers used are designed with different technologies: one allows getting a more representative sampling with the Orbital Raster Scanning technology and the other one allows setting acquisition parameters. The goal was to evaluate which technology could provide the best analytical results. Several parameters were optimized to get the lowest prediction error in the end. The main objective of this study was to evaluate if this kind of instrument would be able to identify substandard medicines. For that purpose, two case-study were explored. At first, a full ICH Q2 (R1) compliant validation was performed for moderate Raman scatterer active pharmaceutical ingredient (API) in a specific formulation. It was successfully validated in the +/- 15% relative total error acceptance limits, with a RMSEP of 0.85% (w/w). Subsequently, it was interesting to evaluate the influence of excipients when the API is a high Raman scatterer. For that purpose, a multiformulation model was developed and successfully validated with a RMSEP of 2.98% (w/w) in the best case. These two studies showed that thanks to the optimization of acquisition parameters, Raman handheld spectrophotometers methods were validated for two different case-study and could be applied to identify substandard medicines.
引用
收藏
页数:9
相关论文
共 34 条
[1]   Quantitation of active pharmaceutical ingredient through the packaging using Raman handheld spectrophotometers: A comparison study [J].
Alaoui Mansouri, M. ;
Sacre, P. -Y. ;
Coic, L. ;
De Bleye, C. ;
Dumont, E. ;
Bouklouze, A. ;
Hubert, Ph ;
Marini, R. D. ;
Ziemons, E. .
TALANTA, 2020, 207
[2]  
[Anonymous], 2004, GUID IND PAT FRAM IN
[3]  
[Anonymous], 2018, Substandard and falsified medical products
[4]  
Bakeev K.A., 2005, J CHEMOMETR, V19, P668, DOI [10.1002/cem.969, DOI 10.1002/CEM.969]
[5]   Comparing the qualitative performances of handheld NIR and Raman spectrophotometers for the detection of falsified pharmaceutical products [J].
Ciza, P. H. ;
Sacre, P-Y ;
Waffo, C. ;
Coic, L. ;
Avohou, H. ;
Mbinze, J. K. ;
Ngono, R. ;
Marini, R. D. ;
Hubert, Ph ;
Ziemons, E. .
TALANTA, 2019, 202 :469-478
[6]   Comparison of hyperspectral imaging techniques for the elucidation of falsified medicines composition [J].
Coic, Laureen ;
Sacre, Pierre-Yves ;
Dispas, Amandine ;
Sakira, Abdoul Karim ;
Fillet, Marianne ;
Marini, Roland D. ;
Hubert, Philippe ;
Ziemons, Eric .
TALANTA, 2019, 198 :457-463
[7]   Portable near-infrared instruments: Application for quality control of polymorphs in pharmaceutical raw materials and calibration transfer [J].
da Silva, Vitor Hugo ;
da Silva, Janson Jose ;
Pereira, Claudete Fernandes .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2017, 134 :287-294
[8]   Critical review of near-infrared spectroscopic methods validations in pharmaceutical applications [J].
De Bleye, C. ;
Chavez, P. -F. ;
Mantanus, J. ;
Marini, R. ;
Hubert, Ph ;
Rozet, E. ;
Ziemons, E. .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2012, 69 :125-132
[9]   Vibrational spectroscopy in analysis of pharmaceuticals: Critical review of innovative portable and handheld NIR and Raman spectrophotometers [J].
Deidda, Riccardo ;
Sacre, Pierre-Yves ;
Clavaud, Matthieu ;
Coic, Laureen ;
Avohou, Hermane ;
Hubert, Philippe ;
Ziemons, Eric .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2019, 114 :251-259
[10]   Quantification of Inkjet-Printed Pharmaceuticals on Porous Substrates Using Raman Spectroscopy and Near-Infrared Spectroscopy [J].
Edinger, Magnus ;
Iftimi, Laura-Diana ;
Markl, Daniel ;
Al-Sharabi, Mohammed ;
Bar-Shalom, Daniel ;
Rantanen, Jukka ;
Genina, Natalja .
AAPS PHARMSCITECH, 2019, 20 (05)