Reticulocyte analysis using flow cytometry

被引:14
作者
Corberand, JX
机构
[1] Laboratoire d'Hématologie, Hôpital Rangueil
来源
HEMATOLOGY AND CELL THERAPY | 1996年 / 38卷 / 06期
关键词
flow cytometry; hematology analyzers; automated reticulocyte counting; reticulocyte indexes;
D O I
10.1007/s00282-996-0487-9
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Automation of the reticulocyte count by means of now cytometry has considerably improved the quality of this investigation. This article deals firstly with the reasons for the poor performance of the microscopic technique and with the physiological principles underlying identification and classification of reticulocytes using RNA labeling. It then outlines the automated methods currently on the market, which can be classified in three categories: a) ''general-purpose'' cytofluorometers, which in clinical laboratories usually deal with lymphocyte immunophenotyping; b) the only commercially available cytofluorometer dedicated to the reticulocyte count; this automat has the advantage of requiring no human intervention as it merely needs to be fed with samples; c) hematology analyzers with specific modules for automatic counting of reticulocytes previously incubated with a non-fluorescent dye. Of the various fluorescent markers available, thiazole orange, DEQTC iodide and auramine are most often used for this basic hematology test. The quality of the count, the availability of new reticulocyte indices (maturation index, percentage of young reticulocytes) and the rapidity of the count give this test renewed value in the practical approach to the diagnosis of anemia, and also open new perspectives in the surveillance of aplastic anemia after chemotherapy or bone marrow grafting.
引用
收藏
页码:487 / 494
页数:8
相关论文
共 49 条
[1]   PREDICTING BONE-MARROW TRANSPLANT ENGRAFTMENT BY AUTOMATED FLOW CYTOMETRIC RETICULOCYTE ANALYSIS [J].
BATJER, JD ;
RIDDELL, K ;
FRITSMA, GA .
LABORATORY MEDICINE, 1994, 25 (01) :22-26
[2]   COMPARISON OF A MODIFIED THIAZOLE ORANGE TECHNIQUE WITH A FULLY AUTOMATED ANALYZER FOR RETICULOCYTE COUNTING [J].
BOWEN, D ;
BENTLEY, N ;
HOY, T ;
CAVILL, I .
JOURNAL OF CLINICAL PATHOLOGY, 1991, 44 (02) :130-133
[3]  
BOWEN DT, 1994, LEUKEMIA, V8, P151
[4]  
BRUGNARA C, 1994, J LAB CLIN MED, V123, P660
[5]   AUTOMATED RETICULOCYTE COUNTING AND MEASUREMENT OF RETICULOCYTE CELLULAR INDEXES - EVALUATION OF THE MILES-H-ASTERISK-3-BLOOD-ANALYZER [J].
BRUGNARA, C ;
HIPP, MJ ;
IRVING, PJ ;
LATHROP, H ;
LEE, PA ;
MINCHELLO, EM ;
WINKELMAN, J .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1994, 102 (05) :623-632
[6]  
CAMBUS JP, 1995, COMMUNICATION
[7]   ENUMERATION OF RETICULOCYTES USING FLUORESCENCE-ACTIVATED FLOW-CYTOMETRY [J].
CORASH, L ;
RHEINSCHMIDT, M ;
LIEU, S ;
MEERS, P ;
BREW, E .
PATHOLOGY AND IMMUNOPATHOLOGY RESEARCH, 1988, 7 (05) :381-394
[8]  
CORBERAND JX, 1991, REV FR LAB, V225, P37
[9]  
D'Hautcourt Jean-Luc, 1994, P325
[10]   EVALUATION OF ERYTHROPOIESIS AFTER BONE-MARROW TRANSPLANTATION - QUANTITATIVE RETICULOCYTE COUNTING [J].
DAVIES, SV ;
CAVILL, I ;
BENTLEY, N ;
FEGAN, CD ;
POYNTON, CH ;
WHITTAKER, JA .
BRITISH JOURNAL OF HAEMATOLOGY, 1992, 81 (01) :12-17