Eco-Friendly Separation of Antihyperlipidemic Combination Using UHPLC Particle-Packed and Monolithic Columns by Applying Green Analytical Chemistry Principles

被引:0
作者
Al-Tannak, Naser F. [1 ]
Hemdan, Ahmed [2 ]
机构
[1] Kuwait Univ, Fac Pharm, Dept Pharmaceut Chem, Safat 13110, Kuwait
[2] Ahram Canadian Univ, Fac Pharm, Pharmaceut Analyt Chem Dept, 6th Of October 12451, Egypt
关键词
UHPLC; fenofibrate; Pravastatin; monolithic; particle packed; green chemistry; PERFORMANCE LIQUID-CHROMATOGRAPHY; DIODE-ARRAY; PRAVASTATIN; BEDS;
D O I
10.3390/separations8120246
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Efficient separation of pharmaceuticals and metabolites with the adequate resolution is a key factor in choosing the most suitable chromatographic method. For quality control, the analysis time is a key factor, especially in pharmacokinetic studies. High back pressure is considered as one of the most important factors in chromatography's flow control, especially in UHPLC. The separation of the anti-hyperlipidemic mixtures was carried out using two columns: a column silica-based particle packed UHPLC and a monolithic column. The systematic suitability of the two columns was compared for the separation of Fenofibrate, its active metabolite, Fenofibric acid and Pravastatin using Atorvastatin as an internal standard. Separation on both columns was obtained using ethanol: buffer potassium dihydrogen orthophosphate pH = 3 (adjusted with orthophosphoric acid) (75:25 v/v) as mobile phase and flow rate 0.8 mL/min. The analytes' peak detection was achieved by using a PDA detector at 287 nm, 214 nm, 236 nm, and 250 nm for Fenofibrate, Fenofibric acid, Pravastatin, and Atorvastatin, respectively. Reduction of back-pressure was achieved with the monolithic column, where the analytes could be completely separated in less than 1.5 min at a flow rate of 5 mL/min. The principles of Green Analytical Chemistry (GAC) were followed throughout the developed method using environmentally safe solvents.
引用
收藏
页数:11
相关论文
共 22 条
[1]   Simultaneous separation of antihyperlipidemic drugs by green ultrahigh-performance liquid chromatography-diode array detector method: Improving the health of liquid chromatography [J].
Alghazi, Mansoor ;
Alanazi, Fars ;
Mohsin, Kazi ;
Siddiqui, Nasir Ali ;
Shakeel, Faiyaz ;
Haq, Nazrul .
JOURNAL OF FOOD AND DRUG ANALYSIS, 2017, 25 (02) :430-437
[2]   Green chemistry and the role of analytical methodology development [J].
Anastas, PT .
CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 1999, 29 (03) :167-175
[3]  
[Anonymous], 2004, EMERG PLANN COMM RIG
[4]   Comparison between monolithic and particle-packed platinum C18 columns in HPLC determination of acidic and basic test mixtures [J].
Atia, Noha N. ;
York, Peter ;
Clark, Brian J. .
JOURNAL OF SEPARATION SCIENCE, 2009, 32 (15-16) :2732-2736
[5]   Applications of silica-based monolithic HPLC columns [J].
Cabrera, K .
JOURNAL OF SEPARATION SCIENCE, 2004, 27 (10-11) :843-852
[6]   Ultra-high-pressure liquid chromatography (UHPLC) in method development [J].
Dong, Michael W. ;
Zhang, Kelly .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2014, 63 :21-30
[7]   Analytical Eco-Scale for assessing the greenness of analytical procedures [J].
Galuszka, Agnieszka ;
Konieczka, Piotr ;
Migaszewski, Zdzislaw M. ;
Namiesnik, Jacek .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2012, 37 :61-72
[8]   High-performance liquid chromatography and derivative spectrophotometry for simultaneous determination of pravastatin and fenofibrate in the dosage form [J].
Hefnawy, Mohamed M. ;
Mohamed, Mostafa S. ;
Abounassif, Mohammed A. ;
Alanazi, Amer M. ;
Mostafa, Gamal A. E. .
ACTA PHARMACEUTICA, 2014, 64 (04) :433-446
[9]   Application of a Fast Separation Method for Anti-diabetics in Pharmaceuticals Using Monolithic Column: Comparative Study With Silica Based C-18 Particle Packed Column [J].
Hemdan, A. ;
Abdel-Aziz, Omar .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2018, 56 (04) :351-357
[10]   Response surface design as a powerful tool for the development of environmentally benign HPLC methods for the determination of two antihypertensive combinations: Greenness assessment by two green analytical chemistry evaluation tools [J].
Hemdan, Ahmed ;
Magdy, Ragaa ;
Farouk, Maha .
JOURNAL OF SEPARATION SCIENCE, 2018, 41 (16) :3213-3223