FDI based on Artificial Neural Network for Low-Voltage-Ride-Through in DFIG-based Wind Turbine

被引:44
作者
Adouni, Amel [1 ]
Chariag, Dhia [1 ]
Diallo, Demba [2 ]
Ben Hamed, Mouna [1 ]
Sbita, Lassaad [1 ]
机构
[1] Univ Gabes, Ecole Natl Ingn Gabes, Lab Syst Photovolta Eoliens & Geothermaux, Zrig Eddakhlania, Tunisia
[2] Univ Paris Sud, UPMC, Cent Supelec, CNRS,Grp Elect Engn Paris GEEPS, F-91192 Gif Sur Yvette, France
关键词
Wind Turbine; Low Voltage Ride Through; Fault Detection and Identification; Electrical grid; Artificial Neural Network; CLASSIFICATION; DIPS;
D O I
10.1016/j.isatra.2016.05.009
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
As per modern electrical grid rules, Wind Turbine needs to operate continually even in presence severe grid faults as Low Voltage Ride Through (LVRT). Hence, a new LVRT Fault Detection and Identification (FDI) procedure has been developed to take the appropriate decision in order to develop the convenient control strategy. To obtain much better decision and enhanced FDI during grid fault, the proposed procedure is based on voltage indicators analysis using a new Artificial Neural Network architecture (ANN). In fact, two features are extracted (the amplitude and the angle phase). It is divided into two steps. The first is fault indicators generation and the second is indicators analysis for fault diagnosis. The first step is composed of six ANNs which are dedicated to describe the three phases of the grid (three amplitudes and three angle phases). Regarding to the second step, it is composed of a single ANN which analysis the indicators and generates a decision signal that describes the function mode (healthy or faulty). On other hand, the decision signal identifies the fault type. It allows distinguishing between the four faulty types. The diagnosis procedure is tested in simulation and experimental prototype. The obtained results confirm and approve its efficiency, rapidity, robustness and immunity to the noise and unknown inputs. (C) 2016 ISA. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:353 / 364
页数:12
相关论文
共 24 条
[1]  
Adouni A, 2015, PROC IEEE INT SYMP, P867, DOI 10.1109/ISIE.2015.7281584
[2]  
Adouni A, 2015, 2015 IEEE INTERNATIONAL CONFERENCE ON INDUSTRIAL TECHNOLOGY (ICIT), P3226, DOI 10.1109/ICIT.2015.7125575
[3]   A New Approach for Classification and Characterization of Voltage Dips and Swells Using 3-D Polarization Ellipse Parameters [J].
Alam, M. R. ;
Muttaqi, K. M. ;
Bouzerdoum, A. .
IEEE TRANSACTIONS ON POWER DELIVERY, 2015, 30 (03) :1344-1353
[4]   Development of High-Performance Grid-Connected Wind Energy Conversion System for Optimum Utilization of Variable Speed Wind Turbines [J].
Amin, Mahmoud M. ;
Mohammed, Osama A. .
IEEE TRANSACTIONS ON SUSTAINABLE ENERGY, 2011, 2 (03) :235-245
[5]  
[Anonymous], 2015, ISA T
[6]  
[Anonymous], THESIS
[7]   Second-order sliding mode control for DFIG-based wind turbines fault ride-through capability enhancement [J].
Benbouzid, Mohamed ;
Beltran, Brice ;
Amirat, Yassine ;
Yao, Gang ;
Han, Jingang ;
Mangel, Herve .
ISA TRANSACTIONS, 2014, 53 (03) :827-833
[8]   Different methods for classification of three-phase unbalanced voltage dips due to faults [J].
Bollen, MHJ ;
Zhang, LD .
ELECTRIC POWER SYSTEMS RESEARCH, 2003, 66 (01) :59-69
[9]   Subcycle Voltage Dip Classification Using Matrix Pencil Method With Ellipse Fitting Algorithm [J].
Chia, Meng Hwee ;
Khambadkone, Ashwin M. .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2015, 51 (02) :1660-1668
[10]  
Da Rosa A., 2012, Fundamentals of Renewable Energy Processes