Electronic nose technology for the detection of microbial and chemical contamination of potable water

被引:31
作者
Canhoto, O [1 ]
Magan, N [1 ]
机构
[1] Cranfield Univ, Inst Biosci & Technol, Grp Appl Mycol, Bedford MK45 4DT, England
关键词
electronic nose; sensor array; water contamination; microorganisms; heavy metals;
D O I
10.1016/j.snb.2004.05.029
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Comparisons were made between two electronic nose systems employing conducting polymer sensor arrays for the early detection and discrimination between bacterial species (Escherichia coli, Enterobacter aerogenes and Pseudomonas aeruginosa, 10(2) CFU mL(-1)), fungal spores (Aspergilus fumigatus, Fusarium culmorurm and Penicillium sp., 10(2) spores mL(-1)) and trace amounts (ppb) of pesticides (DDT and dieldrin). Using PCA, DFA and cluster analysis, it was possible to differentiate between the different bacterial and fungal species after 24 h incubation at 25° C. However, 10 and 100 ppb of the pesticides could not be effectively discriminated from the controls. For bacterial contaminants good correlation between the two different electronic nose systems was possible. Head-space solid phase microextraction (HS-SPME) technique with a gas chromatograph, was used to evaluate and analyse volatile profiles of bacterial cells inoculated in the presence of trace amounts of heavy metals. The resulting chromatograms demonstrated that the volatile patterns from bacterial samples were different from those where a low amount of heavy metals were added. © 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:3 / 6
页数:4
相关论文
共 6 条
[1]   The occurrence of fungi in hospital and community potable waters [J].
Arvanitidou, M ;
Kanellou, K ;
Constantinides, TC ;
Katsouyannopoulos, V .
LETTERS IN APPLIED MICROBIOLOGY, 1999, 29 (02) :81-84
[2]   Electronic nose: a useful tool for monitoring environmental contamination [J].
Baby, RE ;
Cabezas, M ;
de Reca, ENW .
SENSORS AND ACTUATORS B-CHEMICAL, 2000, 69 (03) :214-218
[3]   Searching for process information in the aroma of cell cultures [J].
Bachinger, T ;
Mandenius, CF .
TRENDS IN BIOTECHNOLOGY, 2000, 18 (12) :494-500
[4]   On-line monitoring of wastewater quality: a review [J].
Bourgeois, W ;
Burgess, JE ;
Stuetz, RM .
JOURNAL OF CHEMICAL TECHNOLOGY AND BIOTECHNOLOGY, 2001, 76 (04) :337-348
[5]   Potential for detection of microorganisms and heavy metals in potable water using electronic nose technology [J].
Canhoto, OF ;
Magan, N .
BIOSENSORS & BIOELECTRONICS, 2003, 18 (5-6) :751-754
[6]   An electronic nose system for monitoring the quality of potable water [J].
Gardner, JW ;
Shin, HW ;
Hines, EL ;
Dow, CS .
SENSORS AND ACTUATORS B-CHEMICAL, 2000, 69 (03) :336-341