Identification of frequency-dependent parameters for buried wire in imperfect ground

被引:0
|
作者
Bencheqroune, A [1 ]
Benseddik, M [1 ]
Drissi, KE [1 ]
机构
[1] Fac Sci DM, Fes 30002, Morocco
来源
2003 IEEE International Symposium on Electromagnetic Compatibility (EMC), Vols 1 and 2, Symposium Record | 2003年
关键词
buried wire; earth's conductivity; earth's permittivity; line admittance identification;
D O I
10.1109/ICSMC2.2003.1428246
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Aerial transmission lines possess properties that can be very different from buried cables because the imperfect ground surrounding the wire affects the propagation of induced currents and charges on the cable. This makes modeling efforts more complicated for identifying the behavior of the normalized admittance and impedance of the line which depend strongly on the earth's conductivities and permittivities. In this paper, we shall identify the behavior of the line admittance versus the frequency, the earth's conductivity and permittivity. The closed-form expressions proposed have good agreement with results obtained by the resolution of the modal equation in the frequency domain.
引用
收藏
页码:284 / 287
页数:4
相关论文
共 50 条
  • [1] Measurements of the frequency-dependent impedance of a thin wire with ground return
    Akke, M
    Biro, T
    IEEE TRANSACTIONS ON POWER DELIVERY, 2005, 20 (02) : 1748 - 1752
  • [2] Identification of frequency-dependent parameters in a flexible rotor system
    Wang, Qingyu
    Maslen, Eric H.
    JOURNAL OF ENGINEERING FOR GAS TURBINES AND POWER-TRANSACTIONS OF THE ASME, 2006, 128 (03): : 670 - 676
  • [3] Lightning Transients on Branched Distribution Lines Considering Frequency-Dependent Ground Parameters
    De Conti, Alberto
    Alipio, Rafael
    2016 33RD INTERNATIONAL CONFERENCE ON LIGHTNING PROTECTION (ICLP), 2016,
  • [4] EMP Coupling to Buried Cables in the Frequency-Dependent Soil
    Jiang Wenwen
    Shi Lihua
    Huang Zhengyu
    2015 7TH ASIA-PACIFIC CONFERENCE ON ENVIRONMENTAL ELECTROMAGNETICS (CEEM), 2015, : 225 - 229
  • [5] MODULATED FREQUENCY-DEPENDENT PARAMETERS OF AN OPFET
    SINGH, VK
    PAL, BB
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1987, 134 (09) : C581 - C581
  • [6] Identification of frequency-dependent viscous damping
    Ross, Andrew
    Fossen, Thor I.
    OCEANS 2005, VOLS 1-3, 2005, : 1333 - 1338
  • [7] The Influence of the Frequency-Dependent Behavior of Ground Electrical Parameters on the Lightning Performance of Transmission Lines
    Vasconcellos, Felipe
    Alipio, Rafael
    Moreira, Fernando
    2021 14TH IEEE INTERNATIONAL CONFERENCE ON INDUSTRY APPLICATIONS (INDUSCON), 2021, : 1408 - 1414
  • [8] Computation of ground potential rise and grounding impedance of simple arrangement of electrodes buried in frequency-dependent stratified soil
    de Araujo, Anderson R. J.
    Colqui, Jaimis S. L.
    de Seixas, Claudiner M.
    Kurokawa, Sergio
    Salarieh, Bamdad
    Pissolato Filho, Jose
    Kordi, Behzad
    ELECTRIC POWER SYSTEMS RESEARCH, 2021, 198
  • [9] Analytical calculation of the frequency-dependent litz wire resistance considering the wire connectors
    Barth, Daniel
    Leibfried, Thomas
    Cortese, Giuseppe
    2019 21ST EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS (EPE '19 ECCE EUROPE), 2019,
  • [10] Extension of a modal-domain transmission line model to include frequency-dependent ground parameters
    De Conti, Alberto
    Emidio, Maique Paulo S.