Experimental investigation on performances of trisection helical baffled heat exchangers for oil/water-water heat transfer

被引:42
作者
Chen, Ya-Ping [1 ]
Wang, Wei-han [2 ]
Wu, Jia-Feng [1 ]
Dong, Cong [3 ]
机构
[1] Southeast Univ, Sch Energy & Environm, Minist Educ, Key Lab Energy Thermal Convers & Control, Nanjing 210096, Jiangsu, Peoples R China
[2] Shanghai Inst Technol, Coll Urban Construct & Safety Engn, Shanghai 201418, Peoples R China
[3] Zhejiang Univ Sci & Technol, Sch Mech & Automot Engn, Hangzhou 310023, Zhejiang, Peoples R China
关键词
Heat transfer enhancement; Performance experiments; Helical baffled heat exchangers; Circumferential overlap of baffles; Incline angle of baffle; FLOW;
D O I
10.1016/j.enconman.2015.05.042
中图分类号
O414.1 [热力学];
学科分类号
摘要
The trisection helical baffled shell-and-tube heat exchangers have structural features of more suitable to the equilateral triangular tube layouts and less baffle parts. In particular the circumferential overlap trisection helical baffled shell-and-tube heat exchangers are of anti-shortcut structure that accommodates one row tubes in each circumferential overlapped zone between adjacent baffles for dampening shortcut leakage. The performance tests were conducted on both oil-water and water-water heat transfer in heat exchangers with equilateral triangle tube layout of 16 tubes including five helical baffle schemes with incline angles of 12, 16, 20, 24, 28 and a segmental baffled one for comparison. The test results show that both the shell side heat transfer coefficient h(o) and pressure drop Delta p(o) increase but the comprehensive index h(o)/Delta p(o) decreases with the increase of the mass flow rate of all schemes; and that the shell side heat transfer coefficient, pressure drop and the comprehensive index h(o)/Delta p(o) decrease with the increase of the baffle incline angle at certain mass flow rate, except that the curves of comprehensive index h(o)/Delta p(o) of 12 and 16 helical baffle schemes are almost coincide. The average values of shell side heat transfer coefficient, the comprehensive index h(o)/Delta p(o) of the 12 helical baffled scheme are about 50% higher than those of the segmental one with almost same pressure drop. The correlation equations for shell side Nusselt number and axial Euler number are presented varying with axial Reynolds number, Prandtl number and helical baffle incline angle. (C) 2015 Published by Elsevier Ltd.
引用
收藏
页码:460 / 469
页数:10
相关论文
共 23 条
[1]   Three-dimensional modeling of a Helixchanger® heat exchanger using CFD [J].
Andrews, MJ ;
Master, BI .
HEAT TRANSFER ENGINEERING, 2005, 26 (06) :22-31
[2]  
[Anonymous], 2011, CIESC J
[3]  
[Anonymous], 2001, J. Eng. Thermophys.
[4]   Prediction of Nusselt Number and Friction Factor of Water-Al2O3 Nanofluid Flow in Shell-and-Tube Heat Exchanger with Helical Baffles [J].
Bahiraei, Mehdi ;
Hosseinalipour, Seyed Mostafa ;
Saeedan, Mahdi .
CHEMICAL ENGINEERING COMMUNICATIONS, 2015, 202 (02) :260-268
[5]  
Chen Y.P., 2008, PETRO CHEM EQUIPMENT, V37, P1
[6]   Numerical simulation on flow field in circumferential overlap trisection helical baffle heat exchanger [J].
Chen, Ya-Ping ;
Sheng, Yan-Jun ;
Dong, Cong ;
Wu, Jia-Feng .
APPLIED THERMAL ENGINEERING, 2013, 50 (01) :1035-1043
[7]  
Chen Yaping, 2011, P ASME 2011 INT MECH
[8]   Influence of baffle configurations on flow and heat transfer characteristics of trisection helical baffle heat exchangers [J].
Dong, Cong ;
Chen, Ya-Ping ;
Wu, Jia-Feng .
ENERGY CONVERSION AND MANAGEMENT, 2014, 88 :251-258
[9]  
[董聪 Dong Cong], 2014, [机械工程学报, Journal of Mechanical Engineering], V50, P135
[10]  
GNIELINSKI V, 1976, INT CHEM ENG, V16, P359