Malpositioned Intrauterine Contraceptive Devices Risk Factors, Outcomes, and Future Pregnancies

被引:63
作者
Braaten, Kari P. [1 ]
Benson, Carol B.
Maurer, Rie
Goldberg, Alisa B.
机构
[1] Brigham & Womens Hosp, Dept Obstet Gynecol & Reprod Biol, Boston, MA 02120 USA
关键词
UTERINE PERFORATION; PERFORMANCE; ADENOMYOSIS; POSITION; SYSTEM; MIRENA;
D O I
10.1097/AOG.0b013e3182316308
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
OBJECTIVE: To assess possible risk factors, management, and outcomes for women with malpositioned intrauterine contraception devices (IUDs). METHODS: This retrospective case-control study compared 182 women with malpositioned IUDs shown by ultrasonography at a single institution from 2003 to 2008 with 182 women with properly positioned IUDs. We evaluated whether insertion at 6-9 weeks postpartum, postabortion placement, breastfeeding, type of IUD, pregnancy history, leiomyomas, suspected adenomyosis, and indication for placement were associated with malpositioning. Our study had 70-99% power to detect whether postpartum placement was associated with an odds ratio (OR) of 2-3. RESULTS: Malpositioned devices were noted on 10.4% of ultrasonography scans among women with IUDs having pelvic ultrasonography for any indication. Most malpositioned devices (73.1%) were noted to be in the lower uterine segment or cervix. Insertion of IUDs at 6-9 weeks postpartum was not associated with malpositioning (OR 1.46, 95% confidence interval [CI] 0.81-2.63). Among other possible risk factors examined, suspected adenomyosis was associated with IUD malpositioning (OR 3.04, 95% CI 1.08-8.52), whereas prior vaginal delivery (OR 0.53 95% CI 0.32-0.87) and private insurance (OR 0.38, 95% CI 0.24-0.59) were protective. Approximately two-thirds (66.5%) of malpositioned devices were removed by health care providers. There were more pregnancies within 2 years among those in the case group than those in the control group (19.2% compared with 10.5%, P=.046). All pregnancies were the result of IUD expulsion or removal, and none occurred with a malpositioned IUD known to be in situ. CONCLUSION: Malpositioning of IUDs does not appear to be associated with insertion at 6-9 weeks postpartum. Women with malpositioned IUDs are more likely to become pregnant because of IUD removal without initiation of another highly effective contraceptive method. (Obstet Gynecol 2011;118:1014-20) DOI: 10.1097/AOG.0b013e3182316308
引用
收藏
页码:1014 / 1020
页数:7
相关论文
共 18 条
  • [1] Physiological pathways and molecular mechanisms regulating uterine contractility
    Aguilar, Hector N.
    Mitchell, B. F.
    [J]. HUMAN REPRODUCTION UPDATE, 2010, 16 (06) : 725 - 744
  • [2] Perforations with intrauterine devices - Report from a Swedish survey
    Andersson, K
    Ryde-Blomqvist, E
    Lindell, K
    Odlind, V
    Milsom, I
    [J]. CONTRACEPTION, 1998, 57 (04) : 251 - 255
  • [3] [Anonymous], 2003, Statistical Methods for Rates and Proportions
  • [4] ANTEBY E, 1993, OBSTET GYNECOL, V81, P112
  • [5] Performance of copper intrauterine devices when inserted after an expulsion
    Bahamondes, L
    Diaz, J
    Marchi, NM
    Petta, CA
    Cristofoletti, MD
    Gomez, G
    [J]. HUMAN REPRODUCTION, 1995, 10 (11) : 2917 - 2918
  • [6] THE POSITION OF THE IUD AND INTRAUTERINE PREGNANCIES
    BERNASCHEK, G
    SPERNOL, R
    BECK, A
    [J]. GEBURTSHILFE UND FRAUENHEILKUNDE, 1981, 41 (09) : 645 - 647
  • [7] Caliskan E, 2003, EUR J CONTRACEP REPR, V8, P150
  • [8] PERFORMANCE OF THE COPPER T-380A INTRAUTERINE-DEVICE IN BREASTFEEDING WOMEN
    CHI, IC
    POTTS, M
    WILKENS, LR
    CHAMPION, CB
    [J]. CONTRACEPTION, 1989, 39 (06) : 603 - 618
  • [9] HEARTWELL SF, 1983, OBSTET GYNECOL, V61, P31
  • [10] Bleeding patterns and clinical performance of the levonorgestrel-releasing intrauterine system (Mirena) up to two years
    Hidalgo, M
    Bahamondes, L
    Perrotti, M
    Diaz, J
    Dantas-Monteiro, C
    Petta, C
    [J]. CONTRACEPTION, 2002, 65 (02) : 129 - 132