Correction for the random coincidences in dual-head gamma camera imaging

被引:2
作者
Brasse, D
Comtat, C
Trébossen, R
Tararine, M
Nguyen, QT
Bendriem, B
机构
[1] Serv Hosp Frederic Joliot, Dept Med Res, F-91401 Orsay, France
[2] Sopha Med Vis, Buc, France
关键词
coincidence imaging; dual-head gamma camera; random correction;
D O I
10.1109/23.940177
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Planar large field-of-view gamma camera detectors in coincidence imaging are characterized by a high singles count rate, leading to a high acquired random coincidence rate. We propose and compare two methods to correct the random coincidences that account for the variation of the random count rate during the detector rotation. One method consists of using a uniform distribution for the random coincidences (UD) and the other is based on the single photon distribution (SPD) on each detector. Unlike the UD method, the SPD method accounts for the variation of the spatial distribution of the random coincidences. The UD method leads to an underestimation of the random coincidences inside the object and an overestimation outside the object. The distribution of the random coincidences is better estimated with the SPD method, which allows one to recover contrast values closer to those expected without randoms background.
引用
收藏
页码:864 / 871
页数:8
相关论文
共 21 条
[1]   Randoms variance reduction in 3D PET [J].
Badawi, RD ;
Miller, MP ;
Bailey, DL ;
Marsden, PK .
PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (04) :941-954
[2]  
Brasse D, 1999, EUR J NUCL MED, V26, P1028
[3]   INCREASED SENSITIVITY AND FIELD OF VIEW FOR A ROTATING POSITRON CAMERA [J].
CLACK, R ;
TOWNSEND, D ;
JEAVONS, A .
PHYSICS IN MEDICINE AND BIOLOGY, 1984, 29 (11) :1421-1431
[4]  
Delbeke D, 1999, J NUCL MED, V40, P110
[5]   Estimation of absorbed dose for 2-[F-18]fluoro-2-deoxy-D-glucose using whole-body positron emission tomography and magnetic resonance imaging [J].
Deloar, HM ;
Fujiwara, T ;
Shidahara, M ;
Nakamura, T ;
Watabe, H ;
Narita, Y ;
Itoh, M ;
Miyake, M ;
Watanuki, S .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1998, 25 (06) :565-574
[6]  
FRYER T, 1998, MED IM C TOR CAN
[7]   QUANTITATION IN POSITRON EMISSION COMPUTED-TOMOGRAPHY .4. EFFECT OF ACCIDENTAL COINCIDENCES [J].
HOFFMAN, EJ ;
HUANG, SC ;
PHELPS, ME ;
KUHL, DE .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1981, 5 (03) :391-400
[8]   A PRELIMINARY EVALUATION OF THE SCANDITRONIX PC2048-15B BRAIN SCANNER [J].
HOLTE, S ;
ERIKSSON, L ;
DAHLBOM, M .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1989, 15 (11) :719-721
[9]  
KARP J, 1993, IEEE T MED IMAG, V12
[10]  
Kinahan PE, 1997, IEEE NUCL SCI CONF R, P1918