Assessment of energy expenditure during high intensity cycling and running using a heart rate and activity monitor in young active adults

被引:7
|
作者
Klass, Malgorzata [1 ]
Faoro, Vitalie [2 ]
Carpentier, Alain [1 ]
机构
[1] Univ Libre Bruxelles ULB, Lab Biometry & Exercise Nutr, Brussels, Belgium
[2] Univ Libre Bruxelles ULB, Cardiopulm Exercise Lab, Brussels, Belgium
来源
PLOS ONE | 2019年 / 14卷 / 11期
关键词
PHYSICAL-ACTIVITY; MOTION SENSOR; EXERCISE; ACCELEROMETRY; ACTIHEART; VALIDITY; RELIABILITY; VALIDATION;
D O I
10.1371/journal.pone.0224948
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Objective Although high intensity physical activities may represent a great proportion of the total energy expenditure in active people, only sparse studies have investigated the accuracy of wearable monitors to assess activity related energy expenditure (AEE) during high intensity exercises. Therefore, the purpose of the present study was to investigate the accuracy of the Actiheart, a light portable monitor estimating AEE based on heart rate (HR) and activity counts (ACT), during two popular activities (running and cycling) performed at high intensities. The benefit of an individual calibration of the HR-AEE relationship established during a preliminary maximal test was also evaluated. Methods AEE was estimated in eighteen active adults (4 women and 14 men; 25 +/- 4 yr) with indirect calorimetry using a respiratory gas analysis system (reference method) and the Actiheart during 5-min running and cycling at 60, 75 and 85% of maximal oxygen uptake (VO(2)max) previously determined during a maximal test performed on a treadmill or cycle ergometer. For the Actiheart, AEE was estimated either using the group or individual calibrated equations available in the dedicated software, and their respective HR, ACT or combined HR/ACT algorithms. Results When the HR algorithm was used for cycling and the HR or HR/ACT algorithms for running, AEE measured by the Actiheart increased proportionally to exercise intensity from 60 to 85% VO(2)max (P< 0.001). Compared to indirect calorimetry, the Actiheart group calibrated equations slightly to moderately underestimated (3 to 20%) AEE for the three exercise intensities (P< 0.001). Accuracy of AEE estimation was greatly improved by individual calibration of the HR-AEE relationship (underestimation below 5% and intraclass correlation coefficient [ICC]: 0.79-0.93) compared to group calibration (ICC: 0.64-0.79). Conclusion The Actiheart enables to assess AEE during high intensity running and cycling when the appropriate algorithm is applied. Since an underestimation was present for group calibration, an individual and sport-specific calibration should be performed when a high accuracy is required.
引用
收藏
页数:14
相关论文
共 49 条
  • [21] Accuracy of a combined heart rate and motion sensor for assessing energy expenditure in free-living adults during a double-blind crossover caffeine trial using doubly labeled water as the reference method
    Silva, A. M.
    Santos, D. A.
    Matias, C. N.
    Judice, P. B.
    Magalhaes, J. P.
    Ekelund, U.
    Sardinha, L. B.
    EUROPEAN JOURNAL OF CLINICAL NUTRITION, 2015, 69 (01) : 20 - 27
  • [22] Assessment of low-to-moderate intensity physical activity thermogenesis in young adults using synchronized heart rate and accelerometry with branched-equation modeling
    Thompson, D
    Batterham, AM
    Bock, S
    Robson, C
    Stokes, K
    JOURNAL OF NUTRITION, 2006, 136 (04): : 1037 - 1042
  • [23] Validity of Activity Trackers in Estimating Energy Expenditure During High-Intensity Functional Training
    Morris, Cody E.
    Wessel, Paige A.
    Tinius, Rachel A.
    Schafer, Mark A.
    Maples, Jill M.
    RESEARCH QUARTERLY FOR EXERCISE AND SPORT, 2019, 90 (03) : 377 - 384
  • [24] The effect of whole-body high-intensity interval training on heart rate variability in insufficiently active adults
    Songsorn, Preeyaphorn
    Somnarin, Kawinpop
    Jaitan, Supakij
    Kupradit, Atcharaphan
    JOURNAL OF EXERCISE SCIENCE & FITNESS, 2022, 20 (01) : 48 - 53
  • [25] Feasibility of Using Active Video Gaming as a Means for Increasing Energy Expenditure in Three Nonambulatory Young Adults With Disabilities
    Rowland, Jennifer L.
    Rimmer, James H.
    PM&R, 2012, 4 (08) : 569 - 573
  • [26] Monitoring Heart Rate Variability and Its Association with High-Intensity Running, Psychometric Status, and Training Load in Elite Female Soccer Players during Match Weeks
    Juarez Santos-Garcia, Daniel
    Recuenco Serrano, David
    Carlos Ponce-Bordon, Jose
    Nobari, Hadi
    SUSTAINABILITY, 2022, 14 (22)
  • [27] Comparing the Impact of Heart Rate-Based In-Game Adaptations in an Exergame-Based Functional High-Intensity Interval Training on Training Intensity and Experience in Healthy Young Adults
    Martin-Niedecken, Anna Lisa
    Schwarz, Tiziana
    Schattin, Alexandra
    FRONTIERS IN PSYCHOLOGY, 2021, 12
  • [28] Energy expenditure estimation using accelerometry and heart rate for multiple sclerosis and healthy older adults Validation against a mobile metabolic energy expenditure measurement system
    Bourke, A. K.
    Masse, F.
    Arami, A.
    Aminian, K.
    Healy, M.
    Nelson, John
    O'Dwyer, C.
    Coote, S.
    2014 11TH INTERNATIONAL CONFERENCE ON WEARABLE AND IMPLANTABLE BODY SENSOR NETWORKS WORKSHOPS (BSN WORKSHOPS), 2014, : 1 - 5
  • [29] Sensitivity analysis and comparison of two methods of using heart rate to represent energy expenditure during walking
    Karimi, Mohammad Taghi
    WORK-A JOURNAL OF PREVENTION ASSESSMENT & REHABILITATION, 2015, 51 (04): : 799 - 805
  • [30] Active Videogaming Compared to Unstructured, Outdoor Play in Young Children: Percent Time in Moderate- to Vigorous-Intensity Physical Activity and Estimated Energy Expenditure
    MacArthur, Britt
    Coe, Dawn
    Sweet, Allison
    Raynor, Hollie
    GAMES FOR HEALTH JOURNAL, 2014, 3 (06) : 388 - 394