Quality of image of grating target placed in vitreous of isolated pig eyes photographed through different implanted multifocal intraocular lenses

被引:6
作者
Inoue, Makoto [1 ,2 ]
Noda, Toru [3 ]
Ohnuma, Kazuhiko [4 ]
Bissen-Miyajima, Hiroko [2 ]
Hirakata, Akito [1 ]
机构
[1] Kyorin Univ, Kyorin Eye Ctr, Sch Med, Tokyo 1818611, Japan
[2] Suidobashi Hosp, Tokyo Dent Coll, Dept Ophthalmol, Tokyo, Japan
[3] Natl Hosp Org Tokyo Med Ctr, Dept Ophthalmol, Tokyo, Japan
[4] Chiba Univ, Fac Engn, Dept Med Syst Engn, Chiba 260, Japan
关键词
diffractive multifocal intraocular lens; intraoperative view; refractive multifocal intraocular lens; vitreous surgery; VITREORETINAL SURGERY; VISUAL-ACUITY; VISUALIZATION; RESTOR; MODEL; IOL;
D O I
10.1111/j.1755-3768.2011.02173.x
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To determine the quality of the image of a grating target placed in the vitreous of isolated pig eyes and photographed through implanted refractive and diffractive multifocal intraocular lenses (IOL). Methods: Refractive multifocal (NXG1, PY60MV), diffractive multifocal (ZM900, SA60D3) and monofocal (SA60AT, ZA9003) IOL were implanted in the capsular bag of isolated pig eyes. A grating target was placed in the vitreous and photographed through a flat or a wide-field viewing contact lens. The contrast of the grating targets of different spatial frequencies was measured. Results: With the flat corneal contact lens, the gratings appeared clear and not distorted when viewed through the optics of the NXG1 and PY60MV for far vision but were distorted with reduced contrast when viewed through the optical zone for near vision. The images through the diffractive zone of the ZM900 and SA60D3 were more defocused than with the monofocal IOL (p < 0.005). Ghost images oriented centrifugally of the original image were seen with the ZM900 resulting in lower contrast at higher spatial frequencies than with the SA60D3 with less defocused images only in the central area. With the wide-field viewing contact lens, the images were less defocused and the contrast was comparable to both refractive and diffractive multifocal IOL. Conclusion: Both refractive and diffractive multifocal IOL reduced the contrast of the retinal image when viewed through a flat corneal contact lens but less defocused when viewed through a wide-field viewing contact lens.
引用
收藏
页码:E561 / E566
页数:6
相关论文
共 16 条
[1]   Prospective visual evaluation of apodized diffractive intraocular lenses [J].
Alfonso, Jose F. ;
Fernandez-Vega, Luis ;
Baamonde, M. Begona ;
Mont-Mico, Robert .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (07) :1235-1243
[2]   Visual acuity comparison of 2 models of bifocal aspheric intraocular lenses [J].
Alfonso, Jose F. ;
Puchades, Cristina ;
Fernandez-Vega, Luis ;
Montes-Mico, Robert ;
Valcarcel, Beatriz ;
Ferrer-Blasco, Teresa .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (04) :672-676
[3]  
Charles S, 1991, Multifocal Intraocular Lenses Slack, P209
[4]   One-year outcomes with new-generation multifocal intraocular lenses [J].
Cillino, Salvatore ;
Casuccio, Alessandra ;
Di Pace, Francesco ;
Morreale, Raffaella ;
Pillitteri, Francesco ;
Cillino, Giovanni ;
Lodato, Gaetano .
OPHTHALMOLOGY, 2008, 115 (09) :1508-1516
[5]   Clear lens extraction with multifocal apodized diffractive intraocular lens implantation [J].
Fernandez-Vega, Luis ;
Alfonso, Jose F. ;
Rodriguez, Pedro P. ;
Montes-Mico, Robert .
OPHTHALMOLOGY, 2007, 114 (08) :1491-1498
[6]   Refractive lens exchange: The quadruple win and current perspectives [J].
Fine, I. Howard ;
Hoffman, Richard S. ;
Packer, Mark .
JOURNAL OF REFRACTIVE SURGERY, 2007, 23 (08) :819-824
[7]   Quality of Image of Grating Target Placed in Model of Human Eye With Corneal Aberrations as Observed Through Multifocal Intraocular Lenses [J].
Inoue, Makoto ;
Noda, Toru ;
Mihashi, Toshifumi ;
Ohnuma, Kazuhiko ;
Bissen-Miyajima, Hiroko ;
Hirakata, Akito .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2011, 151 (04) :644-652
[8]   Intraoperative findings during vitreous surgery after implantation of diffractive multifocal intraocular lens [J].
Kawamura, Ryosuke ;
Inoue, Makoto ;
Shinoda, Kei ;
Bissen-Miyajima, Hiroko .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (06) :1048-1049
[9]  
Kumar A, 1996, ACTA OPHTHALMOL SCAN, V74, P415
[10]   Vitreoretinal surgery through multifocal intraocular lenses compared with monofocal intraocular lenses in fluid-filled and air-filled rabbit lyres [J].
Lim, JI ;
Kuppermann, BD ;
Gwon, A ;
Gruber, L .
OPHTHALMOLOGY, 2000, 107 (06) :1083-1088