Calibration of Rogowski Coils With an Integrator at High Currents

被引:29
作者
Draxler, Karel [1 ]
Styblikova, Renata [2 ]
Hlavacek, Jan [1 ]
Prochazka, Radek [1 ]
机构
[1] Czech Tech Univ, Dept Measurement, Fac Elect Engn, Prague 16627, Czech Republic
[2] Czech Metrol Inst, Dept Electromagnet Quant, Lab Fundamental Metrol, Prague 15072, Czech Republic
关键词
Calibration; cross-section winding; high currents; Rogowski coil (Rc); winding unevenness;
D O I
10.1109/TIM.2011.2126090
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper describes the calibration of Rogowski coils with an integrator for current measurement in the current range of up to 30 kA, at mains frequency. A current loop of ten turns with a current of 3 kA was used for calibration. The magnetic field generated in this way differs from the field of one turn placed at the center and passed with a current of 30 kA. The influence of the unevenness of winding and the cross section of the Rogowski coil may cause a calibration error when using a current loop. The difference in the results between using a current loop and one turn, and the measurement uncertainties are given here. Calculations of the mutual inductances of typical Rogowski coils and their uncertainties are presented in the Appendix.
引用
收藏
页码:2434 / 2438
页数:5
相关论文
共 13 条
[1]  
CHEKUROV Y, 2008, P CPEM JUN 8 13, P542
[2]   Calibration of Rogowski Coils at Power Frequencies Using Digital Sampling [J].
Djokic, Branislav .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2009, 58 (04) :751-755
[3]  
DRAXLER K, 2006, P 3 IINT C METR 16 I
[4]   Mutual Inductance of a Precise Rogowski Coil in Dependence of the Position of Primary Conductor [J].
Ferkovic, Luka ;
Ilic, Damir ;
Malaric, Roman .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2009, 58 (01) :122-128
[5]  
Hlavacek J., 2008, 16th IMEKO TC4 International Symposium [CD-ROM], P295
[6]  
*INT ORG STAND, 1993, BIPM IEC IFCC ISO IU
[7]  
Kalantarov P. L., 1986, INDUCTANCE CALCULATI
[8]  
LEE KW, 2001, P 2001 INT S EL INS, P419
[9]   A device for calibrating Rogowski coils in time domain [J].
Lu, Liang ;
Huang, Jianjun ;
Li, Yanming .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2008, 79 (08)
[10]   Machinable Rogowski coil, design, and calibration [J].
Ramboz, JD .