Thin layer chromatography/mass spectrometry

被引:93
作者
Cheng, Sy-Chyi [2 ]
Huang, Min-Zong [1 ]
Shiea, Jentaie [1 ,3 ,4 ]
机构
[1] Natl Sun Yat Sen Univ, Dept Chem, Kaohsiung 80424, Taiwan
[2] Minist Justice, Inst Forens Med, Taipei, Taiwan
[3] Kaohsiung Med Univ, Joint Res Ctr, Natl Sun Yat Sen Univ, Kaohsiung 80424, Taiwan
[4] Kaohsiung Med Univ, Canc Res Ctr, Kaohsiung 80424, Taiwan
关键词
TLC-MS; Ambient ionization; Vacuum-based ionization; Desorption/ionization; Direct sampling; Indirect sampling; IONIZATION-MASS-SPECTROMETRY; ASSISTED-LASER-DESORPTION/IONIZATION; DESORPTION ELECTROSPRAY-IONIZATION; SURFACE SAMPLING PROBE; VOLATILE ORGANIC-COMPOUNDS; TRYPTIC PROTEIN DIGESTS; SONIC-SPRAY IONIZATION; PLANAR CHROMATOGRAPHY; ATMOSPHERIC-PRESSURE; AMBIENT CONDITIONS;
D O I
10.1016/j.chroma.2011.01.077
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Thin layer chromatography (TLC)-a simple, cost-effective, and easy-to-operate planar chromatographic technique-has been used in general chemistry laboratories for several decades to routinely separate chemical and biochemical compounds. Traditionally, chemical and optical methods are employed to visualize the analyte spots on the TLC plate. Because direct identification and structural characterization of the analytes on the TLC plate through these methods are not possible, there has been long-held interest in the development of interfaces that allow TLC to be combined with mass spectrometry (MS)-one of the most efficient analytical tools for structural elucidation. So far, many different TLC-MS techniques have been reported in the literature; some are commercially available. According to differences in their operational processes, the existing TLC-MS systems can be classified into two categories: (i) indirect mass spectrometric analyses, performed by scraping, extracting, purifying, and concentrating the analyte from the TLC plate and then directing it into the mass spectrometer's ion source for further analysis; (ii) direct mass spectrometric analyses, where the analyte on the TLC plate is characterized directly through mass spectrometry without the need for scraping, extraction, or concentration processes. Conventionally, direct TLC-MS analysis is performed under vacuum, but the development of ambient mass spectrometry has allowed analytes on TLC plates to be characterized under atmospheric pressure. Thus, TLC-MS techniques can also be classified into two other categories according to the working environment of the ion source: vacuum-based TLC-MS or ambient TLC-MS. This review article describes the state of the art of TLC-MS techniques used for indirect and direct characterization of analytes on the surfaces of TLC plates. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:2700 / 2711
页数:12
相关论文
共 115 条
[51]   LASER MASS-SPECTROMETRIC ANALYSIS OF COMPOUNDS SEPARATED BY THIN-LAYER CHROMATOGRAPHY [J].
KUBIS, AJ ;
SOMAYAJULA, KV ;
SHARKEY, AG ;
HERCULES, DM .
ANALYTICAL CHEMISTRY, 1989, 61 (22) :2516-2523
[52]   Speciation of chromium by high-performance thin-layer chromatography with direct determination by laser ablation inductively coupled plasma mass spectrometry [J].
Lafleur, Josiane P. ;
Salin, Eric D. .
ANALYTICAL CHEMISTRY, 2008, 80 (17) :6821-6823
[53]  
LEE CS, 2004, CELL, V39, P514
[54]   Gas chromatography connected to multiple channel electrospray ionization mass spectrometry for the detection of volatile organic compounds [J].
Lee, CY ;
Shiea, J .
ANALYTICAL CHEMISTRY, 1998, 70 (13) :2757-2761
[55]   Using electrospray-assisted laser desorption/ionization mass spectrometry to characterize organic compounds separated on thin-layer chromatography plates [J].
Lin, Shu-Yao ;
Huang, Min-Zong ;
Chang, Hui-Chiu ;
Shiea, Jentaie .
ANALYTICAL CHEMISTRY, 2007, 79 (22) :8789-8795
[56]  
LIU QT, 1999, CELL, V855, P617
[57]   A simple device for the extraction of TLC spots: direct coupling with an electrospray mass spectrometer [J].
Luftmann, H .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 378 (04) :964-968
[58]   Automated interface for hyphenation of planar chromatography with mass spectrometry [J].
Luftmann, Heinrich ;
Aranda, Mario ;
Morlock, Gertrud E. .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2007, 21 (23) :3772-3776
[59]   Eucalypt smoke and wildfires: Temperature dependent emissions of biogenic volatile organic compounds [J].
Maleknia, Simin D. ;
Bell, Tina L. ;
Adams, Mark A. .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2009, 279 (2-3) :126-133
[60]   Atmospheric pressure photoionization for coupling liquid-chromatography to mass spectrometry: A review [J].
Marchi, Ivano ;
Rudaz, Serge ;
Veuthey, Jean-Luc .
TALANTA, 2009, 78 (01) :1-18