Development of microbubble aerator for waste water treatment using aerobic activated sludge

被引:269
作者
Terasaka, Koichi [1 ]
Hirabayashi, Ai [2 ]
Nishino, Takanori [2 ]
Fujioka, Satoko [1 ]
Kobayashi, Daisuke [1 ]
机构
[1] Keio Univ, Fac Sci & Technol, Dept Appl Chem, Kohoku Ku, Yokohama, Kanagawa 2238522, Japan
[2] Keio Univ, Grad Sch, Sch Sci Open & Environm Syst, Kohoku Ku, Yokohama, Kanagawa 2238522, Japan
关键词
Aeration; Bubble; Filtration; Multiphase flow; Aerobic activated sludge; Waste water treatment; MASS-TRANSFER;
D O I
10.1016/j.ces.2011.02.043
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
In large-scale waste water treatment plants, the aerobic biochemical reactor is the most important process, where the oxygen supply into the microorganisms often limits the overall waste water treatment rate. On the other hand, several kinds of microbubble distributors have been developed to enrich the oxygen dissolution in water. Therefore, the application of microbubbles for a waste water treatment system was investigated in this study. The oxygen absorption performance of typical microbubble generators was compared with typical bubble generators. To evaluate each bubble generator, the liquid-phase volumetric oxygen transfer coefficient, gas hold-up and power consumption per unit liquid volume were measured in a bubble column attached to each bubble generator. All the microbubble generators allowed the oxygen to dissolve faster than the typical aerators. The spiral liquid flow type microbubble generator had the highest oxygen transfer coefficient even at a low air flow rate although it used more energy than the typical distributors. To improve an industrial waste water treatment system, a novel aeration system utilizing a spiral liquid flow type microbubble generator was proposed in this study. The present system has some advantages such as compact size, portability and fast oxygen dissolution rate. To ensure the performance for organic waste water treatment, the effects of the aeration rate, dissolved oxygen concentration and device properties on the specific consumption rate of model organic waste were investigated. For the novel aeration system, the most suitable conditions to treat organic waste were found. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:3172 / 3179
页数:8
相关论文
共 14 条
[1]   GAS HOLDUP AND VOLUMETRIC MASS-TRANSFER COEFFICIENT IN BUBBLE COLUMNS - EFFECTS OF LIQUID PROPERTIES [J].
AKITA, K ;
YOSHIDA, F .
INDUSTRIAL & ENGINEERING CHEMISTRY PROCESS DESIGN AND DEVELOPMENT, 1973, 12 (01) :76-80
[2]  
HAYASHIDA Y, 2010, P INT C MULT FLOW
[3]  
HIRABAYASHI A, 2009, P ANN M JAP SOC MULT, P228
[4]  
KOBAYASHI D, 2008, P 11 M EUR SOC SON
[5]  
Ohnari H., 1999, Resour. Process., V46, P238
[6]  
Takahashi O., 1998, P 35 NAT HEAT TRANSF, V35, P529
[7]   MASS-TRANSFER IN HIGHLY VISCOUS-LIQUIDS IN A BUBBLE COLUMN WITH CONSTANT-FLOW NOZZLES [J].
TERASAKA, K ;
TSUGE, H .
JOURNAL OF CHEMICAL ENGINEERING OF JAPAN, 1991, 24 (04) :424-429
[8]  
TERASAKA K, 2009, P 5 INT C DIFF SOL L
[9]  
Terasaka K., 2007, KAGAKU KOGAKU, V71, P170
[10]  
Terasaka K., 2008, P 19 INT S TRANSP PH