Inter-story pounding between multistory reinforced concrete structures

被引:47
作者
Karayannis, CG [1 ]
Favvata, MJ [1 ]
机构
[1] Democritus Univ Thrace, Dept Civil Engn, GR-67100 Xanthi, Greece
关键词
structural pounding; inter-story pounding; reinforced concrete structures; ductility requirements; non-linear dynamic analysis;
D O I
10.12989/sem.2005.20.5.505
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The influence of the inter-story structural pounding on the seismic behaviour of adjacent multistory reinforced concrete structures with unequal total heights and different story heights is investigated. Although inter-story pounding is a common case in practice, it has not been studied before in the literature as far as the authors are aware. Fifty two pounding cases, each one for two different seismic excitations, are examined. From the results it can be deduced that: (i) The most important issue in the inter-story pounding is the local effect on the external column of the tall building that suffers the impact from the upper floor slab of the adjacent shorter structure. (ii) The ductility demands for this column are increased comparing with the ones without the pounding effect. In the cases that the two buildings are in contact these demands appear to be critical since they are higher than the available ductility values. In the cases that there is a small distance between the interacting buildings the ductility demands of this column are also higher than the ones of the same column without the pounding effect but they appear to be lower than the available ductility values. (iii) It has to be stressed that in all the examined cases the developed shear forces of this column exceeded the shear strength. Thus, it can be concluded that in inter-story pounding cases the column that suffers the impact is always in a critical condition due to shear action and, furthermore, in the cases that the two structures are in contact from the beginning this column appears to be critical due to high ductility demands as well. The consequences of the impact can be very severe for the integrity of the column and may be a primary cause for the initiation of the collapse of the structure. This means that special measures have to be taken in the design process first for the critically increased shear demands and secondly for the high ductility demands.
引用
收藏
页码:505 / 526
页数:22
相关论文
共 22 条
  • [1] ACI Committee 318, 1995, BUILD COD REQ STRUCT
  • [2] AN INVESTIGATION OF EARTHQUAKE INDUCED POUNDING BETWEEN ADJACENT BUILDINGS
    ANAGNOSTOPOULOS, SA
    SPILIOPOULOS, KV
    [J]. EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 1992, 21 (04) : 289 - 302
  • [3] Arnold C, 1982, Building configuration and seismic design
  • [4] ATHANASIADOU CJ, 1994, EARTHQUAKE SPECTRA, V10
  • [5] Bertero VV., 1986, P INT C, P264
  • [6] Experimental and theoretical simulations of seismic poundings between two adjacent structures
    Chau, KT
    Wei, XX
    Guo, X
    Shen, CY
    [J]. EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2003, 32 (04) : 537 - 554
  • [7] Pounding of structures modelled as non-linear impacts of two oscillators
    Chau, KT
    Wei, XX
    [J]. EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2001, 30 (05) : 633 - 651
  • [8] Eurocode 2, 2002, DES CONCR STRUCT 1
  • [9] Eurocode 8, 2003, Design of structures for earthquake resistance-part 1: general rules, seismic actions and rules for buildings
  • [10] Assessment of seismic pounding hazard for Taipei City
    Jeng, V
    Tzeng, WL
    [J]. ENGINEERING STRUCTURES, 2000, 22 (05) : 459 - 471