Wind Turbine Oriented Solutions to Improve Power Quality and Harmonic Compliance of AC Offshore Wind Power Plants

被引:0
作者
Ruiz, Carlos [1 ]
Abad, Gonzalo [1 ]
Zubiaga, Markel [2 ]
Madariaga, Danel [2 ]
Arza, Joseba [2 ]
机构
[1] Mondragon Univ, Elect & Comp Sci Dept, Arrasate Mondragon 20500, Spain
[2] Ingeteam Res & Dev Europe SL, Zamudio 48170, Spain
来源
IEEE ACCESS | 2021年 / 9卷
关键词
Harmonic analysis; Power harmonic filters; Wind turbines; Codes; Transformers; Wind power generation; Modulation; Wind energy integration; offshore wind power plants; power system harmonics; power harmonic filter; grid code; modulation strategies; SELECTIVE MODAL-ANALYSIS; GENERATION; CONVERTER; SYSTEMS;
D O I
10.1109/ACCESS.2021.3136713
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The operation of offshore wind power plants with respect to power quality and grid code compliance must be verified for different conditions in the design phase using harmonic analysis methods. This paper addresses this verification by first considering a scenario in which wind turbines operate with a typically used modulation strategy, carrier-based pulse width modulation. The studies are performed at several operating points, not only at the rated condition, and at two points of the electrical infrastructure, at the point of connection of the wind turbine and at the point of common coupling of the offshore wind farm. For this type of modulation technique and according to the resonance conditions of the studied offshore system, the harmonic distortion of current signals is relatively high and the compliance of the German - grid code is not achieved. To tackle this, wind turbine manufacturer oriented solutions are proposed with the aim of improving the harmonic emission of the offshore wind farm. The implementation of a particular solution of selective harmonic elimination is presented together with complementary solutions to further improve the harmonic emission of the wind power facility. Furthermore, this paper discloses the modeling approach to account for an adequate harmonic assessment of the wind power plant under study.
引用
收藏
页码:167096 / 167116
页数:21
相关论文
共 37 条
[1]  
Ackermann T., 2012, WIND POWER POWER SYS
[2]  
AlphaVentus, 2019, ALPH VENT
[3]  
[Anonymous], 2013, RUL TRANS PER SPEC R
[4]  
[Anonymous], 2013, SUBMARINE POWER CABL
[5]  
[Anonymous], 2012, HARMONICS LARGE OFFS
[6]  
[Anonymous], 2015, FACT SHEET ALPHA VEN
[7]  
[Anonymous], 2014, XLPE SUBMARINE CABLE
[8]   Comparison of wake model simulations with offshore wind turbine wake profiles measured by sodar [J].
Barthelmie, R. J. ;
Folkerts, L. ;
Larsen, G. C. ;
Rados, K. ;
Pryor, S. C. ;
Frandsen, S. T. ;
Lange, B. ;
Schepers, G. .
JOURNAL OF ATMOSPHERIC AND OCEANIC TECHNOLOGY, 2006, 23 (07) :888-901
[9]  
Blaabjerg Frede., 2018, Control of Power Electronic Converters and Systems, V1
[10]  
Bradt M, 2012, TRANS DISTRIB CONF