Electrocatalytic oxidation of tyrosine at poly(threonine)-film modified carbon paste electrode and its voltammetric determination in real samples

被引:45
作者
Chitravathi, S. [1 ]
Swamy, B. E. Kumara [1 ]
Mamatha, G. P. [2 ]
Chandrashekar, B. N. [1 ]
机构
[1] Kuvempu Univ, Dept PG Studies & Res Ind Chem, Shankaraghatta 577451, Karnataka, India
[2] Kuvempu Univ, Dept Pharmaceut Chem, Shankaraghatta 577451, Karnataka, India
关键词
Tyrosine; Threonine; Carbon paste electrode; Cyclic voltammetry; Differential pulse voltammetry; AMINO-ACIDS; ELECTROCHEMICAL-BEHAVIOR; LIQUID-CHROMATOGRAPHY; MASS-SPECTROMETRY; PHENYLALANINE; TRYPTOPHAN; DOPAMINE;
D O I
10.1016/j.molliq.2012.03.022
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The electrochemical behavior of tyrosine on a poly(threonine)-film modified carbon paste electrode was explored in phosphate buffer solution (pH 7.0) using cyclic voltammetric technique. Tyrosine gave an oxidation peak at 687 mV on bare CPE, whereas an oxidation peak at 671 mV with enhanced peak current was obtained on the poly(threonine)-film modified electrode showing the electrocatalytic nature of the modified electrode. Cyclic voltammetric studies indicated that the oxidation of tyrosine at the electrode surface was irreversible, adsorption controlled and involves one electron. Linear calibration plot between the oxidation peak current and the tyrosine concentration was in the range of 5 x 10(-7) to 1 x 10(-5) M and 1 x 10(-5) to 2.0 x 10(-4) M with a correlation coefficient of 0.999 and 0.997, respectively. Detection limit of tyrosine was found to be 1 x 10(-8) M by differential pulse voltammetric technique. The effect of pH and scan rate of tyrosine was studied. The analytical performance of this sensor was evaluated for the detection of tyrosine in real samples. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:130 / 135
页数:6
相关论文
共 29 条
  • [1] AZUMA Y, 1989, CLIN CHEM, V35, P1399
  • [2] A New Sensor for Simultaneous Determination of Tyrosine and Dopamine Using Iron(III) Doped Zeolite Modified Carbon Paste Electrode
    Babaei, Ali
    Zendehdel, Mojgan
    Khalilzadeh, Balai
    Abnosi, Mohammad
    [J]. CHINESE JOURNAL OF CHEMISTRY, 2010, 28 (10) : 1967 - 1972
  • [3] DEPENDENCE OF 5-HT AND CATECHOLAMINE SYNTHESIS ON CONCENTRATIONS OF PRECURSOR AMINO-ACIDS IN RAT-BRAIN
    CARLSSON, A
    LINDQVIST, M
    [J]. NAUNYN-SCHMIEDEBERGS ARCHIVES OF PHARMACOLOGY, 1978, 303 (02) : 157 - 164
  • [4] Poly(amaranth) film based sensor for resolution of dopamine in the presence of uric acid: A voltammetric study
    Chandra, Umesh
    Swamy, B. E. Kumara
    Gilbert, Ongera
    Pandurangachar, M.
    Reddy, Sathish
    Shankar, S. Sharath
    Sherigara, B. S.
    [J]. CHINESE CHEMICAL LETTERS, 2010, 21 (12) : 1490 - 1492
  • [5] Voltammetric resolution of dopamine in the presence of ascorbic acid and uric acid at poly (calmagite) film coated carbon paste electrode
    Chandra, Umesh
    Swamy, B. E. Kumara
    Gilbert, Ongera
    Sherigara, B. S.
    [J]. ELECTROCHIMICA ACTA, 2010, 55 (24) : 7166 - 7174
  • [6] Electrochemical Behavior and Sensitive Determination of L-Tyrosine with a Gold Nanoparticles Modified Glassy Carbon Electrode
    Cheng, Hao
    Chen, Changdong
    Zhang, Shuai
    [J]. ANALYTICAL SCIENCES, 2009, 25 (10) : 1221 - 1225
  • [7] Electrocatalytic oxidation of sodium levothyroxine with phenyl hydrazine as a mediator at carbon paste electrode: A cyclic voltammetric study
    Chitravathi, S.
    Swamy, B. E. Kumara
    Chandra, Umesh
    Mamatha, G. P.
    Sherigara, B. S.
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2010, 645 (01) : 10 - 15
  • [8] Selective determination of amino acids using flow injection analysis coupled with chemiluminescence detection
    Costin, JW
    Francis, PS
    Lewis, SW
    [J]. ANALYTICA CHIMICA ACTA, 2003, 480 (01) : 67 - 77
  • [9] MICRODIALYSIS AS A TOOL TO MEASURE DIETARY AND REGIONAL EFFECTS ON THE COMPLETE PROFILE OF EXTRACELLULAR AMINO-ACIDS IN THE HYPOTHALAMUS OF RATS
    CURRIE, PJ
    CHANG, N
    LUO, SQ
    ANDERSON, GH
    [J]. LIFE SCIENCES, 1995, 57 (21) : 1911 - 1923
  • [10] Gas chromatography-mass spectrometry method for determination of phenylalanine and tyrosine in neonatal blood spots
    Deng, CH
    Deng, YH
    Wang, B
    Yang, XH
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 780 (02): : 407 - 413