Robot Versus Fluoroscopy-Assisted Vertebroplasty and Kyphoplasty for Osteoporotic Vertebral Compression Fractures: A Systematic Review and Meta-analysis

被引:7
|
作者
Zhang, Yu [1 ]
Peng, Qing [1 ]
Sun, Chenhao [1 ]
Kang, Xiaohe [1 ]
Hu, Man [2 ]
Zhao, Wenjie [2 ]
Liu, Xin [1 ]
Meng, Bo [2 ]
Yang, Sheng [2 ]
Feng, Xinmin [1 ]
Zhang, Liang [1 ]
机构
[1] Yangzhou Univ, Dept Orthoped, Clin Med Coll, Yangzhou, Peoples R China
[2] Dalian Med Univ, Grad Sch, Dalian, Peoples R China
关键词
Kyphoplasty; Meta-analysis; Osteoporotic vertebral compression fractures; Robot-assisted; Systematic review; Vertebroplasty; PERCUTANEOUS VERTEBROPLASTY; METHODOLOGIC QUALITY; MANAGEMENT;
D O I
10.1016/j.wneu.2022.07.083
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
-OBJECTIVE: This study aimed to conduct a systematic review and meta -analysis to compare the clinical results and complications of robot-assisted (RA) versus fluoroscopy-assisted (FA) percutaneous vertebral augmentation (PVA) in the treatment of osteoporotic vertebral compression fractures (OVCFs). -METHODS: A comprehensive search of online databases including PubMed, Embase, Cochrane Library, web of science, and core journals of China National Knowledge Infrastructure were performed to identify related studies reporting the clinical results and complications of RA versus FA-assisted PVA in the treatment of OVCFs. The rate of bone cement leakage was used to assess the complications. After the surgery, the clinical findings were analyzed using the Visual Analog Scale scores and the Oswestry Disability Index scores. The surgical time, intraoperative fluoroscopy frequency, and x-ray exposure duration were used to evaluate the perioperative results. Forest plots were constructed to investigate the results. -RESULTS: RA-PVA had a significantly lower bone cement leakage rate, shorter fluoroscopy frequency, and shorter radiation exposure time of doctors compared with FA-PVA. However, no significant differences were found be-tween RA-PVA and FA-PVA in operative time and radiation exposure time of patients. Furthermore, no statistically differences were found between the 2 groups in Visual Analog Scale and Oswestry Disability Index scores after surgery. -CONCLUSIONS: This meta-analysis showed that RA-PVA can reduce bone cement leakage rate, fluoroscopy frequency, and doctors' radiation exposure time. With the advancement of RA technology, we anticipate more high-quality randomized controlled trials of RA versus FA-PVA in the future to validate and -pdate the results of this analysis.
引用
收藏
页码:120 / 129
页数:10
相关论文
共 50 条
  • [31] Therapeutic Efficacy and Safety of Percutaneous Curved Vertebroplasty in Osteoporotic Vertebral Compression Fractures: A Systematic Review and Meta-Analysis
    Sun, Yan
    Zhang, Yong
    Ma, Haoning
    Tan, Mingsheng
    Zhang, Zhihai
    ORTHOPAEDIC SURGERY, 2023, 15 (10) : 2492 - 2504
  • [32] Does Percutaneous Vertebroplasty or Balloon Kyphoplasty for Osteoporotic Vertebral Compression Fractures Increase the Incidence of New Vertebral Fractures? A Meta-Analysis
    Zhang, Hui
    Xu, Caiyuan
    Zhang, Tongxing
    Gao, Zhongyu
    Zhang, Tao
    PAIN PHYSICIAN, 2017, 20 (01) : E13 - E28
  • [33] Unilateral versus bilateral percutaneous kyphoplasty for osteoporotic vertebral compression fractures A meta-analysis
    Chang, Wenli
    Zhang, Xinyan
    Jiao, Ning
    Yuwen, Peizhi
    Zhu, Yanbin
    Zhang, Fei
    Chen, Wei
    MEDICINE, 2017, 96 (17)
  • [34] Kyphoplasty is associated with reduced mortality risk for osteoporotic vertebral compression fractures: a systematic review and meta-analysis
    Yijian Zhang
    Jun Ge
    Hao Liu
    Junjie Niu
    Shenghao Wang
    Hao Shen
    Hanwen Li
    Chen Qian
    Zhuorun Song
    Pengfei Zhu
    Xuesong Zhu
    Jun Zou
    Huilin Yang
    European Spine Journal, 2024, 33 : 1490 - 1497
  • [35] Balloon kyphoplasty versus percutaneous vertebroplasty for treatment of osteoporotic vertebral compression fractures (OVCFs)
    G. Zhao
    X. Liu
    F. Li
    Osteoporosis International, 2016, 27 : 2823 - 2834
  • [36] Balloon kyphoplasty versus percutaneous vertebroplasty for treatment of osteoporotic vertebral compression fractures (OVCFs)
    Zhao, G.
    Liu, X.
    Li, F.
    OSTEOPOROSIS INTERNATIONAL, 2016, 27 (09) : 2823 - 2834
  • [37] Balloon kyphoplasty versus percutaneous vertebroplasty in treating osteoporotic vertebral compression fracture: grading the evidence through a systematic review and meta-analysis
    Ma, Xin-Long
    Xing, Dan
    Ma, Jian-Xiong
    Xu, Wei-Guo
    Wang, Jie
    Chen, Yang
    EUROPEAN SPINE JOURNAL, 2012, 21 (09) : 1844 - 1859
  • [38] Balloon kyphoplasty versus percutaneous vertebroplasty in treating osteoporotic vertebral compression fracture: grading the evidence through a systematic review and meta-analysis
    Xin-Long Ma
    Dan Xing
    Jian-Xiong Ma
    Wei-Guo Xu
    Jie Wang
    Yang Chen
    European Spine Journal, 2012, 21 : 1844 - 1859
  • [39] Subsequent fractures after vertebroplasty in osteoporotic vertebral fractures: a meta-analysis
    Ding, Ji-Kang
    Zhao, Bin
    Zhai, Yi-fan
    NEUROSURGICAL REVIEW, 2022, 45 (03) : 2349 - 2359
  • [40] A systematic review of unilateral versus bilateral percutaneous vertebroplasty/percutaneous kyphoplasty for osteoporotic vertebral compression fractures
    Yang, Shengping
    Chen, Changxian
    Wang, Hanlong
    Wu, Zhiqiang
    Liu, Lianqun
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2017, 51 (04) : 290 - 297