Robot Versus Fluoroscopy-Assisted Vertebroplasty and Kyphoplasty for Osteoporotic Vertebral Compression Fractures: A Systematic Review and Meta-analysis

被引:10
作者
Zhang, Yu [1 ]
Peng, Qing [1 ]
Sun, Chenhao [1 ]
Kang, Xiaohe [1 ]
Hu, Man [2 ]
Zhao, Wenjie [2 ]
Liu, Xin [1 ]
Meng, Bo [2 ]
Yang, Sheng [2 ]
Feng, Xinmin [1 ]
Zhang, Liang [1 ]
机构
[1] Yangzhou Univ, Dept Orthoped, Clin Med Coll, Yangzhou, Peoples R China
[2] Dalian Med Univ, Grad Sch, Dalian, Peoples R China
关键词
Kyphoplasty; Meta-analysis; Osteoporotic vertebral compression fractures; Robot-assisted; Systematic review; Vertebroplasty; PERCUTANEOUS VERTEBROPLASTY; METHODOLOGIC QUALITY; MANAGEMENT;
D O I
10.1016/j.wneu.2022.07.083
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
-OBJECTIVE: This study aimed to conduct a systematic review and meta -analysis to compare the clinical results and complications of robot-assisted (RA) versus fluoroscopy-assisted (FA) percutaneous vertebral augmentation (PVA) in the treatment of osteoporotic vertebral compression fractures (OVCFs). -METHODS: A comprehensive search of online databases including PubMed, Embase, Cochrane Library, web of science, and core journals of China National Knowledge Infrastructure were performed to identify related studies reporting the clinical results and complications of RA versus FA-assisted PVA in the treatment of OVCFs. The rate of bone cement leakage was used to assess the complications. After the surgery, the clinical findings were analyzed using the Visual Analog Scale scores and the Oswestry Disability Index scores. The surgical time, intraoperative fluoroscopy frequency, and x-ray exposure duration were used to evaluate the perioperative results. Forest plots were constructed to investigate the results. -RESULTS: RA-PVA had a significantly lower bone cement leakage rate, shorter fluoroscopy frequency, and shorter radiation exposure time of doctors compared with FA-PVA. However, no significant differences were found be-tween RA-PVA and FA-PVA in operative time and radiation exposure time of patients. Furthermore, no statistically differences were found between the 2 groups in Visual Analog Scale and Oswestry Disability Index scores after surgery. -CONCLUSIONS: This meta-analysis showed that RA-PVA can reduce bone cement leakage rate, fluoroscopy frequency, and doctors' radiation exposure time. With the advancement of RA technology, we anticipate more high-quality randomized controlled trials of RA versus FA-PVA in the future to validate and -pdate the results of this analysis.
引用
收藏
页码:120 / 129
页数:10
相关论文
共 37 条
[1]  
D'Souza Marissa, 2019, Robot Surg, V6, P9, DOI 10.2147/RSRR.S190720
[2]   Comparison of vertebroplasty and balloon kyphoplasty for treatment of vertebral compression fractures: a meta-analysis of the literature [J].
Eck, Jason C. ;
Nachtigall, Dean ;
Humphreys, S. Craig ;
Hodges, Scott D. .
SPINE JOURNAL, 2008, 8 (03) :488-497
[3]   New technologies in spine - Kyphoplasty and vertebrosplasty for the treatment of painful osteoporotic compression fractures [J].
Garfin, SR ;
Yuan, HA ;
Reiley, MA .
SPINE, 2001, 26 (14) :1511-1515
[4]   Hospital care of osteoporosis-related vertebral fractures [J].
Gehlbach, SH ;
Burge, RT ;
Puleo, E ;
Mar, J .
OSTEOPOROSIS INTERNATIONAL, 2003, 14 (01) :53-60
[5]   Safety and accuracy of robot-assisted versus fluoroscopy-assisted pedicle screw insertion in thoracolumbar spinal surgery: a prospective randomized controlled trial [J].
Han, Xiaoguang ;
Tian, Wei ;
Liu, Yajun ;
Liu, Bo ;
He, Da ;
Sun, Yuqing ;
Han, Xiao ;
Fan, Mingxing ;
Zhao, Jingwei ;
Xu, Yunfeng ;
Zhang, Qi .
JOURNAL OF NEUROSURGERY-SPINE, 2019, 30 (05) :615-622
[6]   Minimally Invasive Robotic Versus Open Fluoroscopic-guided Spinal Instrumented Fusions A Randomized Controlled Trial [J].
Hyun, Seung-Jae ;
Kim, Ki-Jeong ;
Jahng, Tae-Ahn ;
Kim, Hyun-Jib .
SPINE, 2017, 42 (06) :353-358
[7]   Chinese patent medicine for osteoporosis: a systematic review and meta-analysis [J].
Jia, Yan ;
Sun, Jigao ;
Zhao, Yan ;
Tang, Kaiqiang ;
Zhu, Ruizheng ;
Zhao, Wei ;
Wang, Rongtian ;
Zhang, Yanqiong ;
Lin, Na ;
Chen, Weiheng .
BIOENGINEERED, 2022, 13 (03) :5581-5597
[8]   Clinical and Radiologic Outcomes of Robot-Assisted Kyphoplasty versus Fluoroscopy-Assisted Kyphoplasty in the Treatment of Osteoporotic Vertebral Compression Fractures: A Retrospective Comparative Study [J].
Jin, Mengran ;
Ge, Meng ;
Lei, Longyue ;
Li, Fengqing ;
Wu, Mujun ;
Zhang, Guang ;
Pei, Shaolong ;
Zheng, Biao .
WORLD NEUROSURGERY, 2022, 158 :E1-E9
[9]   Current applications of robotics in spine surgery: a systematic review of the literature [J].
Joseph, Jacob R. ;
Smith, Brandon W. ;
Liu, Xilin ;
Park, Paul .
NEUROSURGICAL FOCUS, 2017, 42 (05)
[10]   Evaluation of robot-guided minimally invasive implantation of 2067 pedicle screws [J].
Keric, Naureen ;
Doenitz, Christian ;
Haj, Amer ;
Rachwal-Czyzewicz, Izabela ;
Renovanz, Mirjam ;
Wesp, Dominik M. A. ;
Boor, Stephan ;
Conrad, Jens ;
Brawanski, Alexander ;
Giese, Alf ;
Kantelhardt, Sven R. .
NEUROSURGICAL FOCUS, 2017, 42 (05)