Comparison of the capabilities of liquid isoelectric focusing-one-dimensional nonporous silica reversed-phase liquid chromatography-electrospray ionization time-of-flight mass spectrometry and liquid isoelectric focusing-one-dimensional sodium dodecyl sulfate polyacrylamide gel electrophoresis mass mapping for the analysis of intact protein molecular masses

被引:10
作者
Wall, DB [1 ]
Parus, SJ [1 ]
Lubman, DM [1 ]
机构
[1] Univ Michigan, Dept Chem, Ann Arbor, MI 48109 USA
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2001年 / 763卷 / 1-2期
关键词
mass mapping; molecular mass; proteins;
D O I
10.1016/S0378-4347(01)00382-6
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Nonporous silica reversed-phase HPLC coupled to electrospray ionization with on-line time-of-flight mass spectrometric detection (NPS-RP-HPLC-ESI-TOF-MS) is shown to be an effective liquid phase method for obtaining the molecular masses of proteins from pH fractionated cellular lysates where the method is capable of generating the same banding patterns typically observed using gel phase one-dimensional sodium dodecyl sulfatepolyacrylamide gel electrophoresis. The liquid-phase mass spectrometry-based method provides a mass accuracy of at least 150 ppm, with 4000 mass resolution and provides improved sensitivity as the protein molecular mass (MW) decreases. The liquid and gel phase methods are shown to be complementary in terms of their mass range but the liquid phase method has the advantage over the gel method in that the analysis times are 50 times shorter, the mass accuracy is 70 times better and the resolution is 130 times higher. The liquid phase method is shown to be more effective for detection of proteins below 40 kDa, while the gel phase separation can access many more proteins, including more hydrophobic proteins, at increasing MW. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:139 / 148
页数:10
相关论文
共 35 条
[1]   Use of Rotofor preparative isoelectrofocusing cell in protein purification procedure [J].
Ayala, A ;
Parrado, J ;
Machado, A .
APPLIED BIOCHEMISTRY AND BIOTECHNOLOGY, 1998, 69 (01) :11-16
[2]  
Chang HT, 2001, ELECTROPHORESIS, V22, P394, DOI 10.1002/1522-2683(200102)22:3<394::AID-ELPS394>3.0.CO
[3]  
2-X
[4]  
Chen YJ, 1999, RAPID COMMUN MASS SP, V13, P1907, DOI 10.1002/(SICI)1097-0231(19991015)13:19<1907::AID-RCM732>3.0.CO
[5]  
2-T
[6]   Mass spectrometry of whole proteins eluted from sodium dodecyl sulfate-polyacrylamide gel electrophoresis gels [J].
Cohen, SL ;
Chait, BT .
ANALYTICAL BIOCHEMISTRY, 1997, 247 (02) :257-267
[7]   Characterization of proteins from human cerebrospinal fluid by a combination of preparative two-dimensional liquid-phase electrophoresis and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry [J].
Davidsson, P ;
Westman, A ;
Puchades, M ;
Nilsson, CL ;
Blennow, K .
ANALYTICAL CHEMISTRY, 1999, 71 (03) :642-647
[8]   ISOELECTRIC PROTEIN-PURIFICATION BY ORTHOGONALLY COUPLED HYDRAULIC AND ELECTRIC TRANSPORTS IN A SEGMENTED IMMOBILIZED PH GRADIENT [J].
FAUPEL, M ;
BARZAGHI, B ;
GELFI, C ;
RIGHETTI, PG .
JOURNAL OF BIOCHEMICAL AND BIOPHYSICAL METHODS, 1987, 15 (3-4) :147-161
[9]  
Godovac-Zimmermann J, 2001, MASS SPECTROM REV, V20, P1, DOI 10.1002/1098-2787(2001)20:1<1::AID-MAS1001>3.0.CO
[10]  
2-J