Segmented Capacitance Tomography Electrodes: A Design and Experimental Verifications

被引:19
作者
Mohamad, Elmy Johana [1 ]
Rahim, Ruzairi Abdul [2 ]
Ling, Leow Pei [2 ]
Rahiman, Mohd. Hafiz Fazalul [3 ]
Bin Marwah, Omar Mohd. Faizan [4 ]
Ayob, Nor Muzakkir Nor [2 ]
机构
[1] Univ Tun Hussein Onn Malaysia, Dept Robot & Mech Engn, Fac Elect & Elect Engn, Johor Baharu 86400, Malaysia
[2] Univ Teknologi Malaysia, Proc Tomog & Instrumentat Res Grp, Cybernet Res Alliance, Fac Elect Engn, Utm Skudai 81310, Johor, Malaysia
[3] Univ Malaysia Perlis, Sch Mech Engn, Perlis 02600, Arau, Malaysia
[4] Univ Tun Hussein Onn Malaysia, Dept Mfg & Ind Engn, Fac Elect & Elect Engn, Johor Baharu 86400, Malaysia
关键词
Experimental verification; intelligent sensing module; segmented portable sensor;
D O I
10.1109/JSEN.2011.2174981
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A segmented capacitance tomography system for real-time imaging of multiphase flows is developed and presented in this work. The earlier research shows that the electrical tomography (ECT) system is applicable in flow visualization (image reconstruction). The acquired concentration profile obtained from capacitance measurements able to imaged liquid and gas mixture in pipelines meanwhile the system development is designed to attach on a vessel. The electrode plates which act as the sensor previously has been assembled and fixed on the pipeline, thus it causes obscurity for the production to have any new process installation in the future. Therefore, a segmented electrode sensor offers a new design and idea on ECT system which is portable to be assembled in different diameter sizes of pipeline, and it is flexible to apply in any number due to different size of pipeline without the need of redesigning the sensing module. The new approach of this sensing module contains the integration intelligent electrode sensing circuit on every each of electrode sensors. A microcontroller unit and data acquisition (DAQ) system has been integrated on the electrode sensing circuit and USB technology was applied into the data acquisition system making the sensor able to work independently. Other than that the driven guard that usually placed between adjacent measuring electrodes and earth screen has been embedded on the segmented electrode sensor plates. This eliminates the cable noise and the electrode, so the signal conditioning board can be expanded according to pipe diameter.
引用
收藏
页码:1589 / 1598
页数:10
相关论文
共 17 条
[1]  
[Anonymous], 2010, SENSORS TRANSDUCERS
[2]  
[Anonymous], 2009, EL CAP TOM SYST OP M
[3]   Image reconstruction technique of electrical capacitance tomography for low-contrast dielectrics using Calderon's method [J].
Cao, Zhang ;
Xu, Lijun ;
Wang, Huaxiang .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2009, 20 (10)
[4]  
Daoye Y., 2009, Journal of Physics: Conference Series, V147, P1
[5]  
Flores N., 2005, P COSMOL MULT US C B
[6]   Optimization of an iterative image reconstruction algorithm for electrical capacitance tomography [J].
Liu, S ;
Fu, L ;
Yang, WQ .
MEASUREMENT SCIENCE AND TECHNOLOGY, 1999, 10 (07) :L37-L39
[7]   Development of an Electrical Capacitance Tomography system using four rotating electrodes [J].
Martinez Olmos, A. ;
Carvajal, M. A. ;
Morales, D. P. ;
Garcia, A. ;
Palma, A. J. .
SENSORS AND ACTUATORS A-PHYSICAL, 2008, 148 (02) :366-375
[8]   Multiphase Flow Reconstruction in Oil pipelines by Portable Capacitance Tomography [J].
Mohamad, Elmy Johana ;
Rahim, Ruzairi Abdul .
2010 IEEE SENSORS, 2010, :273-278
[9]  
Tat T. C., 2003, WATER OIL FLOWING IM
[10]  
Wei T. C., 2003, MEASUREMENT 2 PHASE