Carbon Paste Electrode Modified Molecularly Imprinted Polymer as a Sensor for Creatinine Analysis by Stripping Voltammetry

被引:3
作者
Khasanah, M. [1 ]
Darmokoesoemo, H.
Rizki, D. A. [1 ]
机构
[1] Airlangga Univ, Dept Chem, Fac Sci & Technol, Surabaya 60115, Indonesia
来源
6TH INTERNATIONAL CONFERENCE AND WORKSHOPS ON BASIC AND APPLIES SCIENCES | 2017年 / 1888卷
关键词
ASCORBIC-ACID; URIC-ACID; ELECTROCHEMICAL SENSOR; GLASSY-CARBON; FILM;
D O I
10.1063/1.5004310
中图分类号
O59 [应用物理学];
学科分类号
摘要
Modification of carbon paste electrode with molecularly imprinted polymer (CP-MIP) as a voltammetric sensor for creatinine has been developed. MIP was synthesized by reacting melamine, chloranil and creatinine with a mole ratio of 1: 1: 0.1. Creatinine was extracted from polymer chain by using hot water to form a specific imprinted for creatinine molecule. Carbon paste-MIP electrode was prepared by mixing activated carbon, solid paraffin, and MIP in a 45: 40: 15(w/w %) ratio. The optimum conditions of creatinine analysis by differential pulse stripping voltammetry (DPSV) using the developed electrode were the accumulation potential -1000 mV during 90 s at pH 5. The precision of the method for 0.1-0.5 g/L creatinine was 88.7-96.3%, while the detection limit of this method was 0.0315 g/L. The accuracy compared by spectrophotometric method was 95.3-103.6%
引用
收藏
页数:9
相关论文
共 24 条
  • [1] Ansel H.C., 2004, FARMACEUTIC CALCULAT
  • [2] Sensitive determination of Cd and Pb by differential pulse stripping voltammetry with in situ bismuth-modified zeolite doped carbon paste electrodes
    Cao, Linyuan
    Jia, Jianbo
    Wang, Zhenhui
    [J]. ELECTROCHIMICA ACTA, 2008, 53 (05) : 2177 - 2182
  • [3] A disposable single-use electrochemical sensor for the detection of uric acid in human whole blood
    Chen, JC
    Chung, HH
    Hsu, CT
    Tsai, DM
    Kumar, AS
    Zen, JM
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2005, 110 (02) : 364 - 369
  • [4] Delaney T.P., 2001, ELECTROANAL, V14, P221
  • [5] Voltammetric behaviour study of creatinine at phosphomolybdic-polypyrrole film modified electrode
    Guo, MD
    Guo, HX
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2005, 585 (01) : 28 - 34
  • [6] Simultaneous determination of norepinephrine, uric acid, and ascorbic acid at a screen printed carbon electrode modified with polyacrylic acid-coated multi-wall carbon nanotubes
    Huang, Shih-Hung
    Liao, Hsiu-Hsien
    Chen, Dong-Hwang
    [J]. BIOSENSORS & BIOELECTRONICS, 2010, 25 (10) : 2351 - 2355
  • [7] Molecularly imprinted polymers (MIP) based electrochemical sensor for detection of urea and creatinine
    Khadro, Basma
    Sanglar, Corinne
    Bonhomme, Anne
    Errachid, Abdelhamid
    Jaffrezic-Renault, Nicole
    [J]. EUROSENSORS XXIV CONFERENCE, 2010, 5 : 371 - 374
  • [8] Khasanah M., 2013, MEDIA KIMIA FST UNAI, V1, P7
  • [9] IMPRINTING ZEOLITE-MODIFIED GLASSY CARBON AS A VOLTAMMETRIC SENSOR FOR URIC ACID
    Khasanah, Miratul
    Harsini, Muji
    Widati, Alfa Akustia
    [J]. INDONESIAN JOURNAL OF CHEMISTRY, 2013, 13 (02) : 108 - 113
  • [10] MIP sensors on the way to biotech applications: Targeting selectivity
    Kotova, Kira
    Hussain, Munawar
    Mustafa, Ghulam
    Lieberzeit, Peter A.
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2013, 189 : 199 - 202