USage of chitosan for Femoral (USF) haemostasis after percutaneous procedures: a comparative open label study

被引:23
作者
Arbel, Joel [1 ]
Rozenbaum, Eliezer [1 ]
Reges, Orna [1 ]
Neuman, Yoram [1 ]
Levi, Alex [1 ]
Erel, Jacob [1 ]
Haskia, Abdel R. [1 ]
Caneti, Menachem [1 ]
Sherf, Michael [2 ]
Mosseri, Morris [1 ]
机构
[1] Tel Aviv Univ, Sackler Sch Med, Meir Med Ctr, Cardiac Div, IL-44281 Kefar Sava, Israel
[2] Ben Gurion Univ Negev, Soroka Med Ctr, Beer Sheva, Israel
关键词
Chitosan; vascular access; haemostasis; coronary angiography; CARDIAC-CATHETERIZATION; VASCULAR COMPLICATIONS; HEMORRHAGE CONTROL; RANDOMIZED-TRIAL; CLOSURE DEVICE; CORONARY; INTERVENTIONS; ANGIOGRAPHY; REGISTRY; SOCIETY;
D O I
10.4244/EIJV6I9A192
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims: To test the efficacy and safety of a chitosan pad for femoral haemostasis as an adjunct to manual compression. Haemostasis of the femoral artery after coronary angiography by manual compression is time consuming and uncomfortable for the patient. Closure devices are costly and do not reduce vascular complication rate. The HemCon (R) pad is used by the US army to control traumatic bleeding. It consists of chitosan, a positively charged carbohydrate that attracts the negatively charged blood cells and platelets and promotes clotting. Methods and results: Patients undergoing percutaneous coronary angiography were 1:1 randomised for manual compression with regular or HemCon (R) pad. All patients were catheterised with 6 Fr sheath and received 2500 u of heparin. Time to haemostasis, incidence of minor and major bleeding, haematoma size, post-procedural stay at the hospital and level of satisfaction were compared between the two groups. Seventy patients in the Hem Con group and 66 patients in the regular pad groups were recruited. Activated clotting time (ACT) before manual compression was similar, 183.9 +/- 43.4 and 178.3 +/- 34.2 seconds in the HemCon (R) and regular pad groups respectively. Time to haemostasis was 5.6 +/- 2.1 and 8.4 +/- 3.5 minutes in the HemCon (R) and regular pad groups, respectively (p<0.001). Haematoma developed in 6% and 14.8% of patients in the HemCon (R) and regular pad group, respectively (p=0.14). Conclusions: The Hem (R) Con pad significantly decreased time-to-haemostasis compared to the regular pad. The total incidence of haematoma tended to be lower in the HemCon (R) pad compared to the regular pad group.
引用
收藏
页码:1104 / 1109
页数:6
相关论文
共 36 条
[31]   A novel vascular sealing device for closure of percutaneous arterial access sites [J].
Silber, S ;
Gershony, G ;
Schön, B ;
Schön, N ;
Jensen, T ;
Schramm, W .
AMERICAN JOURNAL OF CARDIOLOGY, 1999, 83 (08) :1248-1252
[32]  
Silber S, 1999, HERZ, V24, P620, DOI 10.1007/BF03044486
[33]   Variation in the definitions of bleeding in clinical trials of patients with acute coronary syndromes and undergoing percutaneous coronary interventions and its impact on the apparent safety of antithrombotic drugs [J].
Steinhubl, Steven R. ;
Kastrati, Adnan ;
Berger, Peter B. .
AMERICAN HEART JOURNAL, 2007, 154 (01) :3-11
[34]   Efficacy and safety of a hemostatic puncture closure device with early ambulation after coronary angiography [J].
Ward, SR ;
Casale, P ;
Raymond, R ;
Kussmaul, WG ;
Simpfendorfer, C .
AMERICAN JOURNAL OF CARDIOLOGY, 1998, 81 (05) :569-572
[35]   A special report on the chitosan-based hemostatic dressing: Experience in current combat operations [J].
Wedmore, I ;
McManus, JG ;
Pusateri, AE ;
Holcomb, JB .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2006, 60 (03) :655-658
[36]   CURRENT COMPLICATIONS OF DIAGNOSTIC AND THERAPEUTIC CARDIAC-CATHETERIZATION [J].
WYMAN, RM ;
SAFIAN, RD ;
PORTWAY, V ;
SKILLMAN, JJ ;
MCKAY, RG ;
BAIM, DS .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1988, 12 (06) :1400-1406