Advanced absorbance subtraction; Advanced amplitude modulation; Two-wavelength; Constant center; Spectrum subtraction; Chloramphenicol and prednisolone acetate; PHARMACEUTICAL TERNARY MIXTURE; LIQUID-CHROMATOGRAPHY; MASS-SPECTROMETRY; PREDNISOLONE; CHLORAMPHENICOL; DEXAMETHASONE; FORMULATIONS; VALIDATION; CORTISOL; PLASMA;
D O I
10.1016/j.saa.2015.04.004
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
Smart spectrophotometric methods have been applied and validated for the simultaneous determination of a binary mixture of chloramphenicol (CPL) and prednisolone acetate (PA) without preliminary separation. Two novel methods have been developed; the first method depends upon advanced absorbance subtraction (AAS), while the other method relies on advanced amplitude modulation (AAM); in addition to the well established dual wavelength (DW), ratio difference (RD) and constant center coupled with spectrum subtraction (CC SS) methods. Accuracy, precision and linearity ranges of these methods were determined. Moreover, selectivity was assessed by analyzing synthetic mixtures of both drugs. The proposed methods were successfully applied to the assay of drugs in their pharmaceutical formulations. No interference was observed from common additives and the validity of the methods was tested. The obtained results have been statistically compared to that of official spectrophotometric methods to give a conclusion that there is no significant difference between the proposed methods and the official ones with respect to accuracy and precision. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:328 / 337
页数:10
相关论文
共 43 条
[1]   Simple liquid chromatography method for the rapid simultaneous determination of prednisolone and cortisol in plasma and urine using hydrophilic lipophilic balanced solid phase extraction cartridges [J].
AbuRuz, S ;
Millership, J ;
Heaney, L ;
McElnay, J .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 798 (02) :193-201
[2]   Hypersensitivity reaction to balsalazide [J].
Adhiyaman, V ;
Vaishnavi, A ;
Froese, S .
BRITISH MEDICAL JOURNAL, 2000, 320 (7235) :613-613
[3]   Simultaneous determination of ofloxacin, tetrahydrozoline hydrochloride, and prednisolone acetate by high-performance liquid chromatography [J].
Ali, MS ;
Ghori, M ;
Saeed, A .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2002, 40 (08) :429-433
[4]  
[Anonymous], 2003, VAL AN PROC Q2B
[5]  
[Anonymous], 2007, INDIAN PHARMACOPOEIA, P1005
[6]  
[Anonymous], INT J PHARM PHARM S4
[7]  
Ashban R.A., 2002, J SAUDI CHEM SOC, V6, P399
[8]  
Balaji K, 2008, AFR J PHARM PHARMACO, V2, P157
[9]   A systematic overview of chemotherapy effects in breast cancer [J].
Bergh, J ;
Jönsson, PE ;
Glimelius, B ;
Nygren, P .
ACTA ONCOLOGICA, 2001, 40 (2-3) :253-281
[10]  
British Pharmacopoeia, 2013, STAT OFF BEH MED HEA