Concurrent optical imaging spectroscopy and laser-Doppler Flowmetry: The relationship between blood flow, oxygenation, and volume in rodent barrel cortex

被引:195
作者
Jones, M [1 ]
Berwick, J
Johnston, D
Mayhew, J
机构
[1] Univ Sheffield, Artificial Intelligence Vis Res Unit, Sheffield S10 2TP, S Yorkshire, England
[2] Univ Sheffield, Dept Psychol, Sheffield S10 2TP, S Yorkshire, England
基金
英国惠康基金; 英国医学研究理事会;
关键词
D O I
10.1006/nimg.2001.0808
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Functional magnetic resonance imaging (fMRI) is based on the coupling between neural activity and changes in the concentration of the endogenous paramagnetic contrast agent deoxygenated hemoglobin. Changes in the blood oxygen level-dependent (BOLD) signal result from a complex interplay of blood volume, flow, and oxygen consumption Optical imaging spectroscopy (OIS) has been used to measure changes in blood volume and saturation in response to increased neural activity, while laser Doppler Flowmetry (LDF) can be used to measure flow changes and is now commonplace in neurovascular research. Here, we use concurrent OIS and LDF to examine the hemodynamic response in rodent barrel cortex using electrical stimulation of the whisker pad at varying intensities. Spectroscopic analysis showed that stimulation produced a biphasic early increase in deoxygenated hemoglobin (Hbr), followed by a decrease below baseline, reaching minima at similar to3.7 s. There was no evidence for a corresponding early decrease in oxygenated hemoglobin (HbO(2)), which simply increased after stimulation, reaching maximum at similar to3.2 s. The time courses of changes in blood volume (CBV) and blood flow (CBF) were similar. Both increased within a second of stimulation onset and peaked at similar to2.7 s, after which CBV returned to baseline at a slower rate than CBF, The changes in Hbr, Hbt, and CBF were used to estimate changes in oxygen consumption (CIMRO2), which increased within a second of stimulation and peaked similar to2.2 s after stimulus onset. Analysis of the relative magnitudes of CBV and CBF indicates that the fractional changes of CBV could be simply scaled to match those of CBF, We found the relationship to be well approximated by CBV = CBF0.29. A similar relationship was found using the response to elevated fraction of inspired carbon dioxide (FICO2). (C) 2001 Academic Press.
引用
收藏
页码:1002 / 1015
页数:14
相关论文
共 41 条
[1]   MODEL FOR LASER DOPPLER MEASUREMENTS OF BLOOD-FLOW IN TISSUE [J].
BONNER, R ;
NOSSAL, R .
APPLIED OPTICS, 1981, 20 (12) :2097-2107
[2]   A model for the coupling between cerebral blood flow and oxygen metabolism during neural stimulation [J].
Buxton, RB ;
Frank, LR .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1997, 17 (01) :64-72
[3]  
COPE M, 1991, P SOC PHOTO-OPT INS, V1431, P251, DOI 10.1117/12.44196
[4]   Calibrated functional MRI: Mapping the dynamics of oxidative metabolism [J].
Davis, TL ;
Kwong, KK ;
Weisskoff, RM ;
Rosen, BR .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1998, 95 (04) :1834-1839
[5]   NONOXIDATIVE GLUCOSE CONSUMPTION DURING FOCAL PHYSIOLOGIC NEURAL ACTIVITY [J].
FOX, PT ;
RAICHLE, ME ;
MINTUN, MA ;
DENCE, C .
SCIENCE, 1988, 241 (4864) :462-464
[6]   FOCAL PHYSIOLOGICAL UNCOUPLING OF CEREBRAL BLOOD-FLOW AND OXIDATIVE-METABOLISM DURING SOMATOSENSORY STIMULATION IN HUMAN-SUBJECTS [J].
FOX, PT ;
RAICHLE, ME .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1986, 83 (04) :1140-1144
[7]   SPONTANEOUS WAVES OF CEREBRAL BLOOD-FLOW ASSOCIATED WITH A PATTERN OF ELECTROCORTICAL ACTIVITY [J].
GOLANOV, EV ;
YAMAMOTO, S ;
REIS, DJ .
AMERICAN JOURNAL OF PHYSIOLOGY, 1994, 266 (01) :R204-R214
[8]   Non-invasive visualization of cortical columns by fMRI [J].
Grinvald, A ;
Slovin, H ;
Vanzetta, I .
NATURE NEUROSCIENCE, 2000, 3 (02) :105-107
[9]   EFFECTS OF CHANGES IN PACO2 ON CEREBRAL BLOOD VOLUME, BLOOD FLOW, AND VASCULAR MEAN TRANSIT TIME [J].
GRUBB, RL ;
RAICHLE, ME ;
EICHLING, JO ;
TERPOGOS.MM .
STROKE, 1974, 5 (05) :630-639
[10]  
HAFKENSCHIEL JH, 1952, J PHARMACOL EXP THER, V106, P391