Long-term preservation with interim evaluation of lungs from a non-heart-beating donor after a warm ischemic interval of 90 minutes

被引:48
作者
Rega, FR
Jannis, NC
Verleden, GM
Lerut, TE
Van Raemdonck, DEM
机构
[1] Univ Hosp Gasthuisberg, Dept Thorac Surg, B-3000 Louvain, Belgium
[2] Catholic Univ Louvain, Ctr Expt Surg & Anesthesiol, Louvain, Belgium
[3] Catholic Univ Louvain, Lab Pneumol, Louvain, Belgium
[4] Katholieke Univ Leuven, Hosp Gasthuisberg, Dept Thorac Surg, Louvain, Belgium
关键词
D O I
10.1097/01.sla.0000098625.24363.d9
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective: To investigate the value of in situ preservation and ex vivo evaluation of lungs from a non-heart-beating donor (NHBD) prior to long-term cold storage. Summary Background Data: The use of pulmonary grafts from NHBD might alleviate the organ shortage. However, viability testing of these grafts is mandatory to transplant only those lungs with excellent function. Methods: Pigs were divided into two groups. In the control group, lungs were flushed, explanted, and stored for 4 hours (4degreesC). In the study group, pigs were killed and left untouched for 90 minutes. Thereafter, the lungs were cooled for 150 minutes via chest drains. Graft function of the left lung in both groups was assessed in an isolated ventilation and reperfusion circuit 4 hours after death. The lung was then cooled and stored. Twenty-four hours after death, the pulmonary graft was reassessed in the same model. Results: We did not observe a statistieal significant difference between the two groups in pulmonary vascular resistance, mean airway pressure, and partial oxygen tension at each time point. There was also no statistical significant difference in wet-to-dry weight ratio. Finally, no statistical difference was found within both groups comparing the assessment at 24 hours with the interim evaluation at 4 hours. Conclusions: These data demonstrate that: 1) 90 minutes of warm ischemia and 150 minutes of intrapleural cooling do not affect pulmonary graft function; and 2) NHBD lungs can be safely preserved up to 24 hours. Finally, we have demonstrated that interim ex-vivo evaluation of NHBD lungs is a valid and safe method to assess graft function.
引用
收藏
页码:782 / 792
页数:11
相关论文
共 31 条
[1]   Functional assessment of non-heart-beating donor lungs: prediction of post-transplant function [J].
Aitchison, JD ;
Orr, HE ;
Flecknell, PA ;
Kirby, JA ;
Dark, JH .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2001, 20 (01) :187-194
[2]   Bilateral lobar transplantation with the split lung technique [J].
Artemiou, O ;
Birsan, T ;
Taghavi, S ;
Eichler, I ;
Wisser, W ;
Wolner, E ;
Klepetko, W .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1999, 118 (02) :369-370
[3]   Controlled reperfusion protects lung grafts during a transient early increase in permeability [J].
Bhabra, MS ;
Hopkinson, DN ;
Shaw, TE ;
Onwu, N ;
Hooper, TL .
ANNALS OF THORACIC SURGERY, 1998, 65 (01) :187-192
[4]  
BUCHANAN SA, 1995, ANN THORAC SURG, V60, P38
[5]  
Cohen RG, 2001, WORLD J SURG, V25, P244
[6]  
DARMINI AM, 1994, J HEART LUNG TRANSPL, V13, P741
[7]   EFFECT OF INFLATION ON ADENOSINE-TRIPHOSPHATE CATABOLISM AND LACTATE PRODUCTION DURING NORMOTHERMIC LUNG ISCHEMIA [J].
DELEYN, PRJ ;
LERUT, TE ;
SCHREINEMAKERS, HHJ ;
VANRAEMDONCK, DEM ;
MUBAGWA, K ;
FLAMENG, W .
ANNALS OF THORACIC SURGERY, 1993, 55 (05) :1073-1079
[8]   A STRATEGY TO INCREASE THE DONOR POOL - USE OF CADAVER LUNGS FOR TRANSPLANTATION [J].
EGAN, TM ;
LAMBERT, CJ ;
REDDICK, R ;
ULICNY, KS ;
KEAGY, BA ;
WILCOX, BR .
ANNALS OF THORACIC SURGERY, 1991, 52 (05) :1113-1121
[9]   WHENCE THE LUNGS - A STUDY TO ASSESS SUITABILITY OF DONOR LUNGS FOR TRANSPLANTATION [J].
EGAN, TM ;
BOYCHUK, JE ;
ROSATO, K ;
COOPER, JD .
TRANSPLANTATION, 1992, 53 (02) :420-422
[10]   Warm ischemic time tolerance after ventilated non-heart-beating lung donation in piglets [J].
Greco, R ;
Cordovilla, G ;
Sanz, E ;
Benito, J ;
Criado, A ;
Gonzalez, M ;
De Miguel, E .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1998, 14 (03) :319-325