Performance analysis of a swept-source optical coherence tomography system with a quadrature interferometer and optical amplification

被引:5
|
作者
Mao, Youxin [1 ]
Flueraru, Costel [1 ]
Chang, Shoude [1 ]
Popescu, Dan P. [2 ]
Sowa, Michael G. [2 ]
机构
[1] Natl Res Council Canada, Inst Microstruct Sci, Ottawa, ON K1A 0R6, Canada
[2] Natl Res Council Canada, Inst Biodiagnost, Winnipeg, MB R3B 1Y6, Canada
关键词
Optical coherence tomography; Quadrature interferometer; Semiconductor optical amplifier; Medical; Biological imaging; FREQUENCY-DOMAIN REFLECTOMETRY; MACH-ZEHNDER INTERFEROMETER; TO-NOISE RATIO; SPECTRAL-DOMAIN; PLAQUE; SENSITIVITY;
D O I
10.1016/j.optcom.2011.01.016
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A performance analysis of signal to noise ratio for an optical coherence tomography system with quadrature detection and a semiconductor optical amplifier in the sample arm is discussed. The results are compared and discussed in relation to a conventional OCT system (without optical amplification). An increase of the signal to noise ratio up to 14 dB at a depth of 0.5 mm is obtained compared to the system without the optical amplifier. Overall, an improvement was demonstrated for signal coming from deeper regions within the samples. Arterial plaque from a myocardial infarction-prone Watanabe heritable hyperlipidemic (WHHLMI) rabbit is visualized and characterized using this system. Improvement of signal to noise ratio increases the penetration depth possible for OCT images, from 1 mm to 2 mm within the vessel wall of an artery. Preliminary results show that vulnerable plaque with fibrous cap, macrophage accumulations and calcification in the arterial tissue are measurable with this OCT system. Crown Copyright (C) 2011 Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:2622 / 2627
页数:6
相关论文
共 50 条
  • [1] Advances in swept-source optical coherence tomography and optical coherence tomography angiography
    Zheng, Fang
    Deng, Xiaofeng
    Zhang, Qi
    He, Jingliang
    Ye, Panpan
    Liu, Shan
    Li, Peng
    Zhou, Jian
    Fang, Xiaoyun
    ADVANCES IN OPHTHALMOLOGY PRACTICE AND RESEARCH, 2023, 3 (02): : 67 - 79
  • [2] Comparison of two swept-source optical coherence tomography biometers and a partial coherence interferometer
    Yang, Chan Min
    Lim, Dong Hui
    Kim, Hyo Jeong
    Chung, Tae-Young
    PLOS ONE, 2019, 14 (10):
  • [3] Mirau micro-interferometer for swept-source optical coherence tomography endomicroscopy
    Struk, Przemyslaw
    Bargiel, Sylwester
    Passilly, Nicolas
    Albero, Jorge
    Gorecki, Christophe
    2015 INTERNATIONAL CONFERENCE ON OPTICAL MEMS AND NANOPHOTONICS (OMN), 2015,
  • [4] Novel perspectives on swept-source optical coherence tomography
    Lavinsky F.
    Lavinsky D.
    International Journal of Retina and Vitreous, 2 (1)
  • [5] Ocular biometry with swept-source optical coherence tomography
    Montes-Mico, Robert
    Pastor-Pascual, Francisco
    Ruiz-Mesa, Ramon
    Tana-Rivero, Pedro
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2021, 47 (06): : 802 - 814
  • [6] Widefield Swept-Source Optical Coherence Tomography Angiography
    Shahidzadeh, Anoush
    Kim, Alice Yon
    Aziz, Hassan A.
    Durbin, Mary K.
    Puliafito, Carmen A.
    Kashani, Amir H.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [7] Combined swept-source optical coherence tomography and fluorescence spectroscopy system
    Ryu, Seon Young
    Ju, Myeong Jin
    Park, Kwan Seob
    Eom, Joo Beom
    Lee, Byeong Ha
    MULTIMODAL BIOMEDICAL IMAGING V, 2010, 7557
  • [8] Comparative analysis of 2 swept-source optical coherence tomography biometers
    Sabatino, Francesco
    Matarazzo, Francesco
    Findl, Oliver
    Maurino, Vincenzo
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (08): : 1124 - 1129
  • [9] Analysis of cracks and damages in optical elements by a swept-source optical coherence tomography technique
    Munoz Moreno, Gilberto
    Alcala Ochoa, Noe
    22ND CONGRESS OF THE INTERNATIONAL COMMISSION FOR OPTICS: LIGHT FOR THE DEVELOPMENT OF THE WORLD, 2011, 8011
  • [10] Comparison of Anterior Segment Measurements Between Swept-source Optical Coherence Tomography and Schiempflug Coherence Interferometer
    Song, Jiyun
    Na, Kyung Sun
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2023, 64 (12): : 1158 - 1167