Formaldehyde Exposure in Indoor Air From Public Places and Its Associated Health Risks in Kunshan City, China

被引:14
作者
Liang, Xiaojun [1 ]
Zhang, Jianxin [1 ]
Song, Wenlei [1 ]
Wang, Kewei [2 ]
Zhang, Baoying [3 ]
机构
[1] Kunshan Ctr Dis Control & Prevent, Kunshan, Jiangsu, Peoples R China
[2] Jiangnan Univ, Wuxi, Jiangsu, Peoples R China
[3] China Ctr Dis Control, Beijing, Peoples R China
关键词
employees; formaldehyde exposure; risk assessment; public places; Kunshan city; VOLATILE ORGANIC-COMPOUNDS; ENVIRONMENTS; INHALATION; BUILDINGS; VOCS;
D O I
10.1177/1010539518800348
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
This study assessed the noncarcinogenic and carcinogenic health risks associated with formaldehyde exposure for employees working in 4 categories of public places in Kunshan City in China. A total of 564 different public places, which can be divided into 4 categories (hotel and social interaction places, bathing and beauty places, cultural and entertainment places, and shopping places), and 2716 indoor air samples in those places were measured from January 1, 2010, to December 31, 2015. The average concentration of formaldehyde was 0.57 mg/m(3), which is 5.7 times the acceptable concentration level (0.1 mg/m(3)). The noncarcinogenic risk assessment index for the 4 categories of places tested was above 1. The carcinogenic risk of formaldehyde for employees of the 4 categories of public places was 4.70 x 10(-5) to 1.57 x 10(-4), which was greater than the acceptable carcinogenic risk probability (1 x 10(-6)) from the US Environmental Protection Agency. The highest carcinogenic risk occurred in bathing and beauty places, and male employee carcinogenic risk was greater than that of females. Occupational formaldehyde exposure has serious noncarcinogenic and carcinogenic health risks for employees, and further research is needed to improve indoor air quality in the workplace environment.
引用
收藏
页码:551 / 560
页数:10
相关论文
共 34 条
[1]  
[Anonymous], 1989, RISK ASS GUID SUP A
[2]  
[Anonymous], AIR QUAL GUID EUR
[3]  
[Anonymous], INT RISK INF SYST
[4]   Measured and modeled personal exposures to and risks from volatile organic compounds [J].
Dodson, Robin E. ;
Houseman, E. Andres ;
Levy, Jonathan I. ;
Spengler, John D. ;
Shine, James P. ;
Bennett, Deborah H. .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2007, 41 (24) :8498-8505
[5]  
Duan X., 2015, Highlights of the Chinese exposure factors handbook
[6]  
Duan XiaoLi Duan XiaoLi, 2012, Journal of Environment and Health, V29, P99
[7]  
Feng WR, 2011, J ENV HYGIENE, P7
[8]  
GAQSIQ . General Administration of Quality Supervision Inspection and Quarantine of PRC, 2002, INDOOR AIR QUALITY S
[9]   Increased risk of allergy in children due to formaldehyde exposure in homes [J].
Garrett, MH ;
Hooper, MA ;
Hooper, BM ;
Rayment, PR ;
Abramson, MJ .
ALLERGY, 1999, 54 (04) :330-337
[10]  
GB China National Standard, HYG STAND HOT IND GB