Reversed-phase chiral HPLC and LC/MS analysis with tris(chloromethylphenylcarbamate) derivatives of cellulose and amylose as chiral stationary phases

被引:130
作者
Peng, Liming [1 ]
Jayapalan, Swapna [1 ]
Chankvetadze, Bezhan [2 ]
Farkas, Tivadar [1 ]
机构
[1] Phenomenex Inc, 411 Madrid Ave, Torrance, CA 90501 USA
[2] Tbilisi State Univ, Inst Phys & Analyt Chem, Tbilisi, Georgia
关键词
Polysaccharide-derived chiral stationary; phases; Reversed-phase HPLC; Electrospray LC/MS; Method development and optimization; PERFORMANCE LIQUID-CHROMATOGRAPHY; SUPERCRITICAL-FLUID CHROMATOGRAPHY; MASS-SPECTROMETRY; HUMAN PLASMA; SEPARATION; ENANTIOMERS; PURIFICATION; SYSTEM; ASSAY; SFC;
D O I
10.1016/j.chroma.2010.08.075
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Three polysaccharide-derived chiral stationary phases (CSP) were evaluated for the resolution of more than 200 racemic compounds of pharmaceutical interest in the reversed-phase (RP) separation mode. The population of test probes was carefully evaluated in order to insure that it covers as completely as possible all structural diversity of chiral pharmaceuticals. RP showed the highest potential for successful chiral resolution in HPLC and LC/MS analysis when compared to normal phase and polar organic separation modes. Method development consisted of optimizing mobile phase eluting strength, nature of organic modifier, nature of additive and column temperature. The newer CSPs, cellulose tris(3-chloro-4-methylphenylcarbamate) and amylose tris(2-chloro-5-methylphenylcarbamate), were compared to the commonly used cellulose tris(3,5-dimethylphenylcarbamate) in regards to their ability to provide baseline resolution. Comparable success rates were observed for these three CSPs of quite complimentary chiral recognition ability. The same method development strategy was evaluated for LC/MS analysis. Diethylamine as additive had a negative effect on analyte response with positive ion mode electrospray (ESI+) MS(/MS) detection, even at very low concentration levels (e.g., 0.025%). Decreasing the organic modifier (acetonitrile or methanol) content in the mobile phase often improved enantioselectivity. The column temperature had only a limited effect on chiral resolution, and this effect was compound dependent. Ammonium hydrogencarbonate was the preferred buffer salt for chiral LC with ESI+ MS detection for the successful separation and detection of most basic pharmaceutical racemic compounds. Ammonium acetate is a viable alternative to ammonium hydrogencarbonate. Aqueous formic acid with acetonitrile or methanol can be successfully used in the separation of acidic and neutral racemates. Cellulose tris(3-chloro-4-methylphenylcarbamate) and amylose tris(2-chloro-5-methylphenylcarbamate) emerge as CSPs of wide applicability in either commonly used separation modes rivaling such well established CSPs as cellulose tris(3,5-dimethylphenylcarbamate). Screening protocols including these two new CSPs in the preferentially screened set of chiral columns have higher success rates in achieving baseline resolution in shorter screening time. (c) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:6942 / 6955
页数:14
相关论文
共 47 条
[1]   DIRECT ENANTIOSELECTIVE SEPARATION OF BEVANTOLOL BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY ON NORMAL AND REVERSE CELLULOSE CHIRAL STATIONARY PHASES [J].
ABOULENEIN, HY ;
SERIGNESE, V .
BIOMEDICAL CHROMATOGRAPHY, 1994, 8 (01) :22-25
[2]   Chiral bioanalysis by normal phase high-performance liquid chromatography-atmospheric pressure ionization tandem mass spectrometry [J].
AlebicKolbah, T ;
Zavitsanos, AP .
JOURNAL OF CHROMATOGRAPHY A, 1997, 759 (1-2) :65-77
[3]   Evaluation of generic chiral liquid chromatography screens for pharmaceutical analysis [J].
Anderson, ME ;
Aslan, D ;
Clarke, A ;
Roeraade, J ;
Hagman, G .
JOURNAL OF CHROMATOGRAPHY A, 2003, 1005 (1-2) :83-101
[4]   Chiral separations in polar organic solvent chromatography: Updating a screening strategy with new chlorine-containing 14 polysaccharide-based selectors [J].
Ates, Hasret ;
Mangelings, Debby ;
Heyden, Yvan Vander .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 875 (01) :57-64
[5]   Chiral recognition mechanisms [J].
Berthod, A .
ANALYTICAL CHEMISTRY, 2006, 78 (07) :2093-2099
[6]   Comparative performances of selected chiral HPLC, SFC, and CE systems with a chemically diverse sample set [J].
Borman, P ;
Boughtflower, B ;
Cattanach, K ;
Crane, K ;
Freebairn, K ;
Jonas, G ;
Mutton, I ;
Patel, A ;
Sanders, M ;
Thompson, D .
CHIRALITY, 2003, 15 :S1-S12
[7]   3-fluoro-, 3-chloro- and 3-bromo-5-methylphenylcarbamates of cellulose and amylose as chiral stationary phases for high-performance liquid chromatographic enantioseparation [J].
Chankvetadze, B ;
Chankvetadze, L ;
Sidamonidze, S ;
Kasashima, E ;
Yashima, E ;
Okamoto, Y .
JOURNAL OF CHROMATOGRAPHY A, 1997, 787 (1-2) :67-77
[8]   CHLOROMETHYLPHENYLCARBAMATE DERIVATIVES OF CELLULOSE AS CHIRAL STATIONARY PHASES FOR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
CHANKVETADZE, B ;
YASHIMA, E ;
OKAMOTO, Y .
JOURNAL OF CHROMATOGRAPHY A, 1994, 670 (1-2) :39-49
[9]   DIMETHYLPHENYLCARBAMATES, DICHLOROPHENYLCARBAMATES AND CHLOROMETHYLPHENYLCARBAMATES OF AMYLOSE AS CHIRAL STATIONARY PHASES FOR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
CHANKVETADZE, B ;
YASHIMA, E ;
OKAMOTO, Y .
JOURNAL OF CHROMATOGRAPHY A, 1995, 694 (01) :101-109
[10]   High performance liquid chromatography enantioseparation of chiral pharmaceuticals using tris(chloro-methylphenylcarbamate)s of cellulose [J].
Chankvetadze, B ;
Chankvetadze, L ;
Sidamonidze, S ;
Yashima, E ;
Okamoto, Y .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1996, 14 (8-10) :1295-1303