Precise Determination of Stable Strontium Isotopic Compositions by MC-ICP-MS

被引:16
作者
Xu, Juan [1 ]
Yang, Shouye [1 ]
Yang, Yueheng [3 ]
Liu, Yongsheng [2 ]
Xie, Xiaolei [1 ]
机构
[1] Tongji Univ, State Key Lab Marine Geol, Shanghai 200092, Peoples R China
[2] State Key Lab Geol Proc & Mineral Resources, Wuhan 430074, Peoples R China
[3] Chinese Acad Sci, Inst Geol & Geophys, State Key Lab Lithospher Evolut, Beijing 100029, Peoples R China
基金
中国国家自然科学基金;
关键词
INDUCTIVELY-COUPLED PLASMA; MASS BIAS CORRECTION; RATIO MEASUREMENTS; LASER-ABLATION; SR-87/SR-86; SPECTROMETRY; DELTA-SR-88/86; FRACTIONATION; CARBONATES; SAMPLES;
D O I
10.46770/AS.2020.02.003
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
The investigation of variations within the non-traditional stable Sr isotope composition in various natural systems has gained a broader interest in recent years. Although significant improvements in the analytical precision for isotopic ratio analysis have been made, the accurate determination of stable Sr isotopic ratios is still a challenge. This study shows the key controlling factors affecting the precise determination of stable Sr isotopic ratios by using Neptune Plus MC-ICP-MS, including matrix effect, internal standard correction and nebulizer fractionation effect. Further, a novel step is presented in the Sr purification by using Sr-spec (R) resin, which increased the recovery rates to > 98.5%. In this work, the mass bias effects between Zr-92/Zr-90 and Sr-88/Sr-86 were investigated and compared, and a 3 similar to 5-fold improvement in the precision of the determination of Sr-88/Sr-86 was obtained compared to that based on only the standard-sample-bracketing technique. Moreover, nebulizer fractionation was illustrated by using an in-house standard solution, Alfa Sr, and the seawater standard, IAPSO. As for the matrix effect, residual Ca in the purified Sr fraction was evaluated and showed insignificant influence. Overall, a feasible, highly-efficient procedure for the stable Sr separation and analysis was developed. The seawater standard, IAPSO, yielded delta Sr-88/86 = 0.374 +/- 0.028 parts per thousand (2SD, n = 23), which is in agreement with reported data. The long-term reproducibility for the rock standard materials, BCR-2 and BHVO-2, yielded delta Sr-88/86 = 0.232 +/- 0.015 parts per thousand (2SD, n = 10), delta Sr-88/86 = 0.249 +/- 0.014940 (2SD, n = 7), respectively, and agrees well with published data. The in-house standard solution, Alfa Sr, was produced to check for the long-term reproducibility of the method and yielded a comparable value of 0.113 +/- 0.039 parts per thousand (2SD, n = 46) over 6 months.
引用
收藏
页码:64 / 73
页数:10
相关论文
共 55 条
[41]   The effect of nitric acid concentration and nebulizer gas flow rates on aerosol properties and transport rates in inductively coupled plasma sample introduction [J].
Stewart, II ;
Olesik, JW .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1998, 13 (11) :1249-1256
[42]   LASER ABLATION FOR THE INTRODUCTION OF SOLID SAMPLES INTO AN INDUCTIVELY COUPLED PLASMA FOR ATOMIC-EMISSION SPECTROMETRY [J].
THOMPSON, M ;
GOULTER, JE ;
SIEPER, F .
ANALYST, 1981, 106 (1258) :32-39
[43]   Problems in obtaining precise and accurate Sr isotope analysis from geological materials using laser ablation MC-ICPMS [J].
Vroon, P. Z. ;
van der Wagt, B. ;
Koornneef, J. M. ;
Davies, G. R. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2008, 390 (02) :465-476
[44]   Sr isotope ratio measurements by double-focusing MC-ICPMS: techniques, observations and pitfalls [J].
Waight, T ;
Baker, J ;
Peate, D .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2002, 221 (03) :229-244
[45]   Vaporization and ionization of laser ablation generated aerosols in an inductively coupled plasma mass spectrometer -: implications from ion distribution maps [J].
Wang, Zhongke ;
Hattendorf, Bodo ;
Guenther, Detlef .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2006, 21 (11) :1143-1151
[46]   Seasonal changes in the radiogenic and stable strontium isotopic composition of Xijiang River water: Implications for chemical weathering [J].
Wei, Gangjian ;
Ma, Jinlong ;
Liu, Ying ;
Xie, Luhua ;
Lu, Weijian ;
Deng, Wenfeng ;
Ren, Zhongyuan ;
Zeng, Ti ;
Yang, Yonghong .
CHEMICAL GEOLOGY, 2013, 343 :67-75
[47]   Chromatographic Separation of Cd from Plants via Anion Exchange Resin for an Isotope Determination by Multiple Collector ICP-MS [J].
Wei, Rongfei ;
Guo, Qingjun ;
Wen, Hanjie ;
Peters, Marc ;
Yang, Junxing ;
Tian, Liyan ;
Han, Xiaokun .
ANALYTICAL SCIENCES, 2017, 33 (03) :335-341
[48]   In situ Sr-isotope analysis of carbonates by LA-MC-ICP-MS:: interference corrections, high spatial resolution and an example from otolith studies [J].
Woodhead, J ;
Swearer, S ;
Hergta, J ;
Maasa, R .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2005, 20 (01) :22-27
[49]   Use of Zr for mass bias correction in strontium isotope ratio determinations using MC-ICP-MS [J].
Yang, Lu ;
Peter, Charlotte ;
Panne, Ulrich ;
Sturgeon, Ralph E. .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2008, 23 (09) :1269-1274
[50]   Re-evaluation of interferences of doubly charged ions of heavy rare earth elements on Sr isotopic analysis using multi-collector inductively coupled plasma mass spectrometry [J].
Yang, Yue-Heng ;
Wu, Fu-Yuan ;
Xie, Lie-Wen ;
Chu, Zhu-Yin ;
Yang, Jin-Hui .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2014, 97 :118-123