Precise Determination of Stable Strontium Isotopic Compositions by MC-ICP-MS

被引:16
作者
Xu, Juan [1 ]
Yang, Shouye [1 ]
Yang, Yueheng [3 ]
Liu, Yongsheng [2 ]
Xie, Xiaolei [1 ]
机构
[1] Tongji Univ, State Key Lab Marine Geol, Shanghai 200092, Peoples R China
[2] State Key Lab Geol Proc & Mineral Resources, Wuhan 430074, Peoples R China
[3] Chinese Acad Sci, Inst Geol & Geophys, State Key Lab Lithospher Evolut, Beijing 100029, Peoples R China
基金
中国国家自然科学基金;
关键词
INDUCTIVELY-COUPLED PLASMA; MASS BIAS CORRECTION; RATIO MEASUREMENTS; LASER-ABLATION; SR-87/SR-86; SPECTROMETRY; DELTA-SR-88/86; FRACTIONATION; CARBONATES; SAMPLES;
D O I
10.46770/AS.2020.02.003
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
The investigation of variations within the non-traditional stable Sr isotope composition in various natural systems has gained a broader interest in recent years. Although significant improvements in the analytical precision for isotopic ratio analysis have been made, the accurate determination of stable Sr isotopic ratios is still a challenge. This study shows the key controlling factors affecting the precise determination of stable Sr isotopic ratios by using Neptune Plus MC-ICP-MS, including matrix effect, internal standard correction and nebulizer fractionation effect. Further, a novel step is presented in the Sr purification by using Sr-spec (R) resin, which increased the recovery rates to > 98.5%. In this work, the mass bias effects between Zr-92/Zr-90 and Sr-88/Sr-86 were investigated and compared, and a 3 similar to 5-fold improvement in the precision of the determination of Sr-88/Sr-86 was obtained compared to that based on only the standard-sample-bracketing technique. Moreover, nebulizer fractionation was illustrated by using an in-house standard solution, Alfa Sr, and the seawater standard, IAPSO. As for the matrix effect, residual Ca in the purified Sr fraction was evaluated and showed insignificant influence. Overall, a feasible, highly-efficient procedure for the stable Sr separation and analysis was developed. The seawater standard, IAPSO, yielded delta Sr-88/86 = 0.374 +/- 0.028 parts per thousand (2SD, n = 23), which is in agreement with reported data. The long-term reproducibility for the rock standard materials, BCR-2 and BHVO-2, yielded delta Sr-88/86 = 0.232 +/- 0.015 parts per thousand (2SD, n = 10), delta Sr-88/86 = 0.249 +/- 0.014940 (2SD, n = 7), respectively, and agrees well with published data. The in-house standard solution, Alfa Sr, was produced to check for the long-term reproducibility of the method and yielded a comparable value of 0.113 +/- 0.039 parts per thousand (2SD, n = 46) over 6 months.
引用
收藏
页码:64 / 73
页数:10
相关论文
共 55 条
[11]   Time resolved inductively coupled plasma mass spectrometry measurements with individual, monodisperse drop sample introduction [J].
Dziewatkoski, MP ;
Daniels, LB ;
Olesik, JW .
ANALYTICAL CHEMISTRY, 1996, 68 (07) :1101-1109
[12]   Direct high-precision measurements of the 87Sr/86Sr isotope ratio in natural water, carbonates and related materials by multiple collector inductively coupled plasma mass spectrometry (MC-ICP-MS) [J].
Ehrlich, S ;
Gavrieli, I ;
Dor, LB ;
Halicz, L .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2001, 16 (12) :1389-1392
[13]   Determination of temperature-dependent stable strontium isotope (88Sr/86Sr) fractionation via bracketing standard MC-ICP-MS [J].
Fietzke, J. ;
Eisenhauer, A. .
GEOCHEMISTRY GEOPHYSICS GEOSYSTEMS, 2006, 7
[14]   MONODISPERSE DRIED MICROPARTICULATE INJECTOR FOR ANALYTICAL INSTRUMENTATION [J].
FRENCH, JB ;
ETKIN, B ;
JONG, R .
ANALYTICAL CHEMISTRY, 1994, 66 (05) :685-691
[15]   Impact of the Particle Diameter on Ion Cloud Formation from Gold Nanoparticles in ICPMS [J].
Fuchs, Joshua ;
Aghaei, Maryam ;
Schachel, Tilo D. ;
Sperling, Michael ;
Bogaerts, Annemie ;
Karst, Uwe .
ANALYTICAL CHEMISTRY, 2018, 90 (17) :10271-10278
[16]   Strontium stable isotopes fractionate in the soil environments? [J].
Halicz, Ludwik ;
Segal, Irina ;
Fruchter, Noa ;
Stein, Mordechai ;
Lazar, Boaz .
EARTH AND PLANETARY SCIENCE LETTERS, 2008, 272 (1-2) :406-411
[17]  
Heumann KG, 1998, J ANAL ATOM SPECTROM, V13, P1001
[18]   INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY SIGNAL FLUCTUATIONS DUE TO INDIVIDUAL AEROSOL DROPLETS AND VAPORIZING PARTICLES [J].
HOBBS, SE ;
OLESIK, JW .
ANALYTICAL CHEMISTRY, 1992, 64 (03) :274-283
[19]   Spatial profiling of analyte signal intensities in inductively coupled plasma mass spectrometry [J].
Holliday, AE ;
Beauchemin, D .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2004, 59 (03) :291-311
[20]   A New Strategy for Highly Sensitive Immunoassay Based on Single-Particle Mode Detection by Inductively Coupled Plasma Mass Spectrometry [J].
Hu, Shenghong ;
Liu, Rui ;
Zhang, Sichun ;
Huang, Zhi ;
Xing, Zhi ;
Zhang, Xinrong .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2009, 20 (06) :1096-1103