Approach to Hemoptysis in the Modern Era

被引:44
作者
Gagnon, Sebastien [1 ]
Quigley, Nicholas [1 ]
Dutau, Herve [2 ]
Delage, Antoine [1 ]
Fortin, Marc [1 ]
机构
[1] Inst Univ Pneumol & Cardiol Quebec, 2725 Ch Ste Foy, Quebec City, PQ G1V 4G5, Canada
[2] Hop Nord Marseille, AP HM, 13915 Chemin Bourrely, Marseille, France
关键词
BRONCHIAL ARTERY EMBOLIZATION; MASSIVE HEMOPTYSIS; TRANEXAMIC ACID; PULMONARY HEMORRHAGE; ENDOBRONCHIAL VALVES; FIBEROPTIC BRONCHOSCOPY; FIBRINOGEN-THROMBIN; COMPUTED-TOMOGRAPHY; CT-ANGIOGRAPHY; MANAGEMENT;
D O I
10.1155/2017/1565030
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Hemoptysis is a frequent manifestation of a wide variety of diseases, with mild to life-threatening presentations. The diagnostic workup and the management of severe hemoptysis are often challenging. Advances in endoscopic techniques have led to different new therapeutic approaches. Cold saline, vasoconstrictive and antifibrinolytic agents, oxidized regenerated cellulose, bio-compatible glue, laser photocoagulation, argon plasma coagulation, and endobronchial stents and valves are amongst the tools available to the bronchoscopist. In this article, we review the evidence regarding the definition, etiology, diagnostic modalities, and treatment of severe hemoptysis in the modern era with emphasis on bronchoscopic techniques.
引用
收藏
页数:11
相关论文
共 115 条
[11]  
Bhalla Ashu, 2015, Oman Med J, V30, P119, DOI 10.5001/omj.2015.26
[12]   New procedure: Bronchoscopic endobronchial sealing - A new mode of managing hemoptysis [J].
Bhattacharyya, P ;
Dutta, A ;
Samanta, AN ;
Chowdhury, SR .
CHEST, 2002, 121 (06) :2066-2069
[13]  
Bonlokke S., 2015, DAN MED J, V81, P186
[14]   Occlusive endobronchial stent placement as a novel management approach to massive hemoptysis from lung cancer [J].
Brandes, Johann C. ;
Schmidt, Eric ;
Yung, Rex .
JOURNAL OF THORACIC ONCOLOGY, 2008, 3 (09) :1071-1072
[15]  
BREUER HWM, 1989, EUR RESPIR J, V2, P225
[16]   Temporary Endobronchial Embolization with Silicone Spigots for Moderate Hemoptysis: A Retrospective Study [J].
Bylicki, O. ;
Vandemoortele, T. ;
Laroumagne, S. ;
Astoul, P. ;
Dutau, H. .
RESPIRATION, 2012, 84 (03) :225-230
[17]  
CAHILL BC, 1994, CLIN CHEST MED, V15, P147
[18]   Devices for lung isolation used by anesthesiologists with limited thoracic experience -: Comparison of double-lumen endotracheal tube, Univent® torque control blocker, and Arndt wire-guided endobronchial Blocker® [J].
Campos, JH ;
Hallam, EA ;
Van Natta, T ;
Kernstine, KH .
ANESTHESIOLOGY, 2006, 104 (02) :261-266
[19]   Impact of multidetector CT-angiography on the emergency management of severe hemoptysis [J].
Chalumeau-Lemoine, Ludivine ;
Khalil, Antoine ;
Prigent, Helene ;
Carette, Marie-France ;
Fartoukh, Muriel ;
Parrot, Antoine .
EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (11) :E742-E747
[20]  
Chan VL, 2009, INT J TUBERC LUNG D, V13, P1167