Time-Resolved Interventional Cardiac C-arm Cone-Beam CT: An Application of the PICCS Algorithm

被引:71
作者
Chen, Guang-Hong [1 ]
Theriault-Lauzier, Pascal [1 ]
Tang, Jie [1 ]
Nett, Brian [1 ]
Leng, Shuai [1 ]
Zambelli, Joseph [1 ]
Qi, Zhihua [1 ]
Bevins, Nicholas [1 ]
Raval, Amish [2 ]
Reeder, Scott [3 ]
Rowley, Howard [3 ]
机构
[1] Univ Wisconsin, Dept Med Phys, Madison, WI 53792 USA
[2] Univ Wisconsin, Dept Med, Madison, WI 53792 USA
[3] Univ Wisconsin, Dept Radiol, Madison, WI 53792 USA
基金
美国国家卫生研究院; 加拿大自然科学与工程研究理事会;
关键词
Cardiac cone-beam CT; compressed sensing; high temporal resolution; interventional imaging; DUAL-ENERGY CT; COMPUTED-TOMOGRAPHY; IMAGE-RECONSTRUCTION; LEFT ATRIUM; TEMPORAL RESOLUTION; CATHETER ABLATION; PULMONARY VEINS; ANGIOGRAPHY; PERFORMANCE; ESOPHAGUS;
D O I
10.1109/TMI.2011.2172951
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Time-resolved cardiac imaging is particularly interesting in the interventional setting since it would provide both image guidance for accurate procedural planning and cardiac functional evaluations directly in the operating room. Imaging the heart in vivo using a slowly rotating C-arm system is extremely challenging due to the limitations of the data acquisition system and the high temporal resolution required to avoid motion artifacts. In this paper, a data acquisition scheme and an image reconstruction method are proposed to achieve time-resolved cardiac cone-beam computed tomography imaging with isotropic spatial resolution and high temporal resolution using a slowly rotating C-arm system. The data are acquired within 14 s using a single gantry rotation with a short scan angular range. The enabling image reconstruction method is the prior image constrained compressed sensing (PICCS) algorithm. The prior image is reconstructed from data acquired over all cardiac phases. Each cardiac phase is then reconstructed from the retrospectively gated cardiac data using the PICCS algorithm. To validate the method, several studies were performed. Both numerical simulations using a hybrid motion phantom with static background anatomy as well as physical phantom studies have been used to demonstrate that the proposed method enables accurate reconstruction of image objects with a high isotropic spatial resolution. A canine animal model scanned in vivo was used to further validate the method.
引用
收藏
页码:907 / 923
页数:17
相关论文
共 50 条
[21]   Initial experience of percutaneous transthoracic needle biopsy of lung nodules using C-arm cone-beam CT systems [J].
Kwang Nam Jin ;
Chang Min Park ;
Jin Mo Goo ;
Hyun Ju Lee ;
Youkyung Lee ;
Jung Im Kim ;
So Young Choi ;
Hyo-Cheol Kim .
European Radiology, 2010, 20 :2108-2115
[22]   Radiation Dose Reduction and CNR Enhancement in C-arm Cone Beam CT [J].
Niu, Kai ;
Tang, Jie ;
Royalty, Kevin ;
Ozkan, Orhan ;
Strother, Charles ;
Aagaard-Kienitz, Beverly ;
Pulfer, Kari ;
Chen, Guang-Hong .
MEDICAL IMAGING 2013: PHYSICS OF MEDICAL IMAGING, 2013, 8668
[23]   A learning-based method for online adjustment of C-arm Cone-beam CT source trajectories for artifact avoidance [J].
Thies, Mareike ;
Zaech, Jan-Nico ;
Gao, Cong ;
Taylor, Russell ;
Navab, Nassir ;
Maier, Andreas ;
Unberath, Mathias .
INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2020, 15 (11) :1787-1796
[24]   A model based algorithm for perfusion estimation in interventional C-arm CT systems [J].
Wagner, Martin ;
Deuerling-Zheng, Yu ;
Moehlenbruch, Markus ;
Bendszus, Martin ;
Boese, Jan ;
Heiland, Sabine .
MEDICAL PHYSICS, 2013, 40 (03)
[25]   Intraoperative cone-beam CT for head and neck surgery: Feasibility of clinical implementation using a prototype mobile C-arm [J].
King, Emma ;
Daly, Michael J. ;
Chan, Harley ;
Bachar, Gideon ;
Dixon, Benjamin J. ;
Siewerdsen, Jeffrey H. ;
Irish, Jonathan C. .
HEAD AND NECK-JOURNAL FOR THE SCIENCES AND SPECIALTIES OF THE HEAD AND NECK, 2013, 35 (07) :959-967
[26]   Artifacts caused by insufficient contrast medium filling during C-arm cone-beam CT scans: A phantom study [J].
Terabe M. ;
Ichikawa H. ;
Kato T. ;
Koshida K. .
Radiological Physics and Technology, 2014, 7 (1) :25-34
[27]   Quantification of temporal resolution improvement factor in SMART-RECON based time-resolved C-arm Cone beam computed tomography angiography (TR-CBCTA) [J].
Garrett, John W. ;
Li, Yinsheng ;
Li, Ke ;
Wu, Yijing ;
Johnson, Kevin ;
Schafer, Sebastian ;
Chen, Guang-Hong .
PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (19)
[28]   Investigating 4D respiratory cone-beam CT imaging for thoracic interventions on robotic C-arm systems: a deformable phantom study [J].
Reynolds, Tess ;
Dillon, Owen ;
Ma, Yiqun ;
Hindley, Nicholas ;
Stayman, J. Webster ;
Bazalova-Carter, Magdalena .
PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2024, 47 (04) :1751-1762
[29]   Intraoperative C-arm cone-beam computed tomography in fenestrated/branched aortic endo grafting [J].
Dijkstra, Martijn L. ;
Eagleton, Matthew J. ;
Greenberg, Roy K. ;
Mastracci, Tara ;
Hernandez, Adrian .
JOURNAL OF VASCULAR SURGERY, 2011, 53 (03) :583-590
[30]   C-Arm Cone-Beam CT Virtual Navigation-Guided Percutaneous Mediastinal Mass Biopsy: Diagnostic Accuracy and Complications [J].
Kim, Hyungjin ;
Park, Chang Min ;
Lee, Sang Min ;
Goo, Jin Mo .
EUROPEAN RADIOLOGY, 2015, 25 (12) :3508-3517