Time-Resolved Interventional Cardiac C-arm Cone-Beam CT: An Application of the PICCS Algorithm

被引:70
|
作者
Chen, Guang-Hong [1 ]
Theriault-Lauzier, Pascal [1 ]
Tang, Jie [1 ]
Nett, Brian [1 ]
Leng, Shuai [1 ]
Zambelli, Joseph [1 ]
Qi, Zhihua [1 ]
Bevins, Nicholas [1 ]
Raval, Amish [2 ]
Reeder, Scott [3 ]
Rowley, Howard [3 ]
机构
[1] Univ Wisconsin, Dept Med Phys, Madison, WI 53792 USA
[2] Univ Wisconsin, Dept Med, Madison, WI 53792 USA
[3] Univ Wisconsin, Dept Radiol, Madison, WI 53792 USA
基金
美国国家卫生研究院; 加拿大自然科学与工程研究理事会;
关键词
Cardiac cone-beam CT; compressed sensing; high temporal resolution; interventional imaging; DUAL-ENERGY CT; COMPUTED-TOMOGRAPHY; IMAGE-RECONSTRUCTION; LEFT ATRIUM; TEMPORAL RESOLUTION; CATHETER ABLATION; PULMONARY VEINS; ANGIOGRAPHY; PERFORMANCE; ESOPHAGUS;
D O I
10.1109/TMI.2011.2172951
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Time-resolved cardiac imaging is particularly interesting in the interventional setting since it would provide both image guidance for accurate procedural planning and cardiac functional evaluations directly in the operating room. Imaging the heart in vivo using a slowly rotating C-arm system is extremely challenging due to the limitations of the data acquisition system and the high temporal resolution required to avoid motion artifacts. In this paper, a data acquisition scheme and an image reconstruction method are proposed to achieve time-resolved cardiac cone-beam computed tomography imaging with isotropic spatial resolution and high temporal resolution using a slowly rotating C-arm system. The data are acquired within 14 s using a single gantry rotation with a short scan angular range. The enabling image reconstruction method is the prior image constrained compressed sensing (PICCS) algorithm. The prior image is reconstructed from data acquired over all cardiac phases. Each cardiac phase is then reconstructed from the retrospectively gated cardiac data using the PICCS algorithm. To validate the method, several studies were performed. Both numerical simulations using a hybrid motion phantom with static background anatomy as well as physical phantom studies have been used to demonstrate that the proposed method enables accurate reconstruction of image objects with a high isotropic spatial resolution. A canine animal model scanned in vivo was used to further validate the method.
引用
收藏
页码:907 / 923
页数:17
相关论文
共 50 条
  • [1] An Enhanced SMART-RECON Algorithm for Time-Resolved C-Arm Cone-Beam CT Imaging
    Li, Yinsheng
    Garrett, John W.
    Li, Ke
    Strother, Charles
    Chen, Guang-Hong
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2020, 39 (06) : 1894 - 1905
  • [2] Time-resolved cardiac interventional cone-beam CT reconstruction from fully truncated projections using the prior image constrained compressed sensing (PICCS) algorithm
    Lauzier, Pascal Theriault
    Tang, Jie
    Chen, Guang-Hong
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (09) : 2461 - 2476
  • [3] Role of C-Arm Cone-Beam CT in Chemoembolization for Hepatocellular Carcinoma
    Kim, Hyo-Cheol
    KOREAN JOURNAL OF RADIOLOGY, 2015, 16 (01) : 114 - 124
  • [4] GPU based parallel acceleration for fast C-arm cone-beam CT reconstruction
    Chen, Ken
    Wang, Cheng
    Xiong, Jing
    Xie, Yaoqin
    BIOMEDICAL ENGINEERING ONLINE, 2018, 17
  • [5] C-arm orbits for metal artifact avoidance (MAA) in cone-beam CT
    Wu, P.
    Sheth, N.
    Sisniega, A.
    Uneri, A.
    Han, R.
    Vijayan, R.
    Vagdargi, P.
    Kreher, B.
    Kunze, H.
    Kleinszig, G.
    Vogt, S.
    Lo, S-F
    Theodore, N.
    Siewerdsen, J. H.
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (16)
  • [6] Time-resolved C-arm cone beam CT angiography (TR-CBCTA) imaging from a single short-scan C-arm cone beam CT acquisition with intra-arterial contrast injection
    Li, Yinsheng
    Garrett, John W.
    Li, Ke
    Wu, Yijing
    Johnson, Kevin
    Schafer, Sebastian
    Strother, Charles
    Chen, Guang-Hong
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (07)
  • [7] Accelerated statistical reconstruction for C-arm cone-beam CT using Nesterov's method
    Wang, Adam S.
    Stayman, J. Webster
    Otake, Yoshito
    Vogt, Sebastian
    Kleinszig, Gerhard
    Siewerdsen, Jeffrey H.
    MEDICAL PHYSICS, 2015, 42 (05) : 2699 - 2708
  • [8] Soft-tissue imaging with C-arm cone-beam CT using statistical reconstruction
    Wang, Adam S.
    Stayman, J. Webster
    Otake, Yoshito
    Kleinszig, Gerhard
    Vogt, Sebastian
    Gallia, Gary L.
    Khanna, A. Jay
    Siewerdsen, Jeffrey H.
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (04) : 1005 - 1026
  • [9] C-arm cone-beam computed tomography in interventional oncology: technical aspects and clinical applications
    Floridi, Chiara
    Radaelli, Alessandro
    Abi-Jaoudeh, Nadine
    Grass, Micheal
    De Lin, Ming
    Chiaradia, Melanie
    Geschwind, Jean-Francois
    Kobeiter, Hishman
    Squillaci, Ettore
    Maleux, Geert
    Giovagnoni, Andrea
    Brunese, Luca
    Wood, Bradford
    Carrafiello, Gianpaolo
    Rotondo, Antonio
    RADIOLOGIA MEDICA, 2014, 119 (07): : 521 - 532
  • [10] High-Performance C-Arm Cone-Beam CT Guidance of Thoracic Surgery
    Schafer, Sebastian
    Otake, Yoshito
    Uneri, Ali
    Mirota, Daniel J.
    Nithiananthan, Sajendra
    Stayman, J. Webster
    Zbijewski, Wojciech
    Kleinszig, Gerhard
    Graumann, Rainer
    Sussman, Marc
    Siewerdsen, Jeffrey H.
    MEDICAL IMAGING 2012: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2012, 8316