256x256 2-D array transducer with row-column addressing for 3-D imaging

被引:17
|
作者
Seo, Chi Hyang [1 ]
Yen, Jesse T. [1 ]
机构
[1] Univ So Calif, Dept Biomed Engn, Los Angeles, CA 90089 USA
来源
2007 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1-6 | 2007年
关键词
2-D array; 1-3; composite; 3-D imaging; row-column;
D O I
10.1109/ULTSYM.2007.599
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
In previous work we presented experimental results using a prototype 64 x 64 2-D array with row-column methods. The main benefits of this row-column design are a reduced number of interconnects, a T/R switching scheme with a simple diode circuit, and an ability to perform transmit beamforming In azimuth direction and receive beamforming in elevational direction for a volumetric imaging of targets near the transducer. In this paper, we present experimental results acquired from a new 256 x 256 2-D array transducer. The center frequency was 6.4 MHz with a -6 dill bandwidth of 57%. The series resonant impedance was 120 Ohms near 5.8 MHz. The mean crosstalk of the adjacent element was -22 dB in the frequency range of interest. For a wire target, in azimuth direction with transmit beamforming, we measured the -6 dB beamwidth to be 0.75 rum at a depth of 25.5 mm compared to a theoretical beamwidth of 0.68 mm. We successfully acquired 3-D images of a wire target and a cylindrical anechoic cyst of 10 mm in diameter made of graphite scatterers in gelatin.
引用
收藏
页码:2381 / 2384
页数:4
相关论文
共 50 条
  • [1] A 256 x 256 2-D Array Transducer with Row-Column Addressing for 3-D Rectilinear Imaging
    Seo, Chi Hyung
    Yen, Jesse T.
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2009, 56 (04) : 837 - 847
  • [2] Recent results using a 256 x 256 2-D array transducer for 3-D Rectilinear Imaging
    Seo, Chi Hyung
    Yen, Jesse T.
    2008 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-4 AND APPENDIX, 2008, : 1146 - 1149
  • [3] 64 X 64 2-D array transducer with row-column addressing
    Seo, Chi Hyting
    Yen, Jesse T.
    2006 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-5, PROCEEDINGS, 2006, : 74 - 77
  • [4] 3-D Ultrasound Imaging Performance of a Row-Column Addressed 2-D Array Transducer: A Measurement Study
    Rasmussen, Morten Fischer
    Jensen, Jorgen Arendt
    2013 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2013, : 1452 - 1455
  • [5] The Design and Analysis of Split Row-Column Addressing Array for 2-D Transducer
    Li, Xu
    Jia, Yanping
    Ding, Mingyue
    Ming Yuchi
    SENSORS, 2016, 16 (10)
  • [6] The design of split row-column addressing array for 2D transducer
    YanpingJia
    LiushuaiLv
    Ding, Mingyue
    Yuchi, Ming
    MEDICAL IMAGING 2014: ULTRASONIC IMAGING AND TOMOGRAPHY, 2014, 9040
  • [7] 256x256 GaN ultraviolet imaging array
    Huang, ZC
    Mott, DB
    Shu, PK
    SPACE TECHNOLOGY AND APPLICATIONS INTERNATIONAL FORUM - 1998, PTS 1-3: 1ST CONF ON GLOBAL VIRTUAL PRESENCE; 1ST CONF ON ORBITAL TRANSFER VEHICLES; 2ND CONF ON APPLICAT OF THERMOPHYS IN MICROGRAV; 3RD CONF ON COMMERCIAL DEV OF SPACE; 3RD CONF ON NEXT GENERAT LAUNCH SYST; 15TH SYMP ON SPACE NUCL POWER AND PROPULSION, 1998, (420): : 39 - 43
  • [8] Beamformer for a Lensed Row-Column Array in 3-D Ultrasound Imaging
    Salari, Ali
    Audoin, Melanie
    Tomov, Borislav Gueorguiev
    Yiu, Billy Y. S.
    Thomsen, Erik Vilain
    Arendt Jensen, Jorgen
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2025, 72 (02) : 238 - 250
  • [9] 3-D Spatial Compounding Using a Row-Column Array
    Awad, Samer I.
    Yen, Jesse T.
    ULTRASONIC IMAGING, 2009, 31 (02) : 120 - 130
  • [10] 3D ultrasound imaging performance of a row-column addressed 2D array transducer: a simulation study
    Rasmussen, Morten Fischer
    Jensen, Jorgen Arendt
    MEDICAL IMAGING 2013: ULTRASONIC IMAGING, TOMOGRAPHY, AND THERAPY, 2013, 8675