Selenium-based digital radiography versus high-resolution storage phosphor radiography in the detection of solitary pulmonary nodules without calcification: Receiver operating characteristic curve analysis

被引:9
作者
Awai, K [1 ]
Komi, M [1 ]
Hori, S [1 ]
机构
[1] Rinku Gen Med Ctr, Dept Radiol, Osaka 5988577, Japan
关键词
D O I
10.2214/ajr.177.5.1771141
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of this study was to compare selenium-based digital radiography with high-resolution storage phosphor radiography for the detection of solitary pulmonary nodules without calcification. MATERIALS AND METHODS. One hundred twenty-four patients underwent selenium-based digital radiography, high-resolution storage phosphor radiography, and chest CT for evaluation of pulmonary nodules. Thirty-one patients with pulmonary nodules smaller than 3 cm in diameter and 40 patients with normal lungs were selected for receiver operating characteristic curve analysis. Five board-certified radiologists who were unaware of the CT results independently reviewed each of the hard copies of selenium-based digital radiography and storage phosphor radiography, identified pulmonary nodules, and graded their confidence for the presence of each nodule. For each radiologist, we calculated the areas under the receiver operating characteristic curve (AUC) for selenium-based digital radiography and storage phosphor radiography. RESULTS. The average performance of selenium-based digital radiography (AUC = 0.72) was higher than that of high-resolution storage phosphor radiography (AUC = 0.64), which is statistically significant (p <0.05). CONCLUSION. Our results indicate that selenium-based digital radiography is superior to high-resolution storage phosphor radiography for detecting solitary pulmonary nodules without calcification.
引用
收藏
页码:1141 / 1144
页数:4
相关论文
共 16 条
[1]  
Blume H, 1992, J Digit Imaging, V5, P67
[2]   TECHNICAL EVALUATION OF A DIGITAL CHEST RADIOGRAPHY SYSTEM THAT USES A SELENIUM DETECTOR [J].
CHOTAS, HG ;
FLOYD, CE ;
RAVIN, CE .
RADIOLOGY, 1995, 195 (01) :264-270
[3]   SELENIUM-BASED DIGITAL RADIOGRAPHY OF THE CHEST - RADIOLOGISTS PREFERENCE COMPARED WITH FILM-SCREEN RADIOGRAPHS [J].
FLOYD, CE ;
BAKER, JA ;
CHOTAS, HG ;
DELONG, DM ;
RAVIN, CE .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 165 (06) :1353-1358
[4]   DIGITAL CHEST IMAGING WITH A SELENIUM DETECTOR - COMPARISON WITH CONVENTIONAL RADIOGRAPHY FOR VISUALIZATION OF SPECIFIC ANATOMIC REGIONS OF THE CHEST [J].
HEESEWIJK, HPM ;
NEITZEL, U ;
VANDERGRAAF, Y ;
DEVALOIS, JC ;
FELDBERG, MAM .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 165 (03) :535-540
[5]   INTERPRETATION OF SUBTLE INTERSTITIAL CHEST ABNORMALITIES - CONVENTIONAL RADIOGRAPHY VERSUS HIGH-RESOLUTION STORAGE-PHOSPHOR RADIOGRAPHY - A PRELIMINARY-STUDY [J].
IKEZOE, J ;
KOHNO, N ;
KIDO, S ;
TAKEUCHI, N ;
JOHKOH, T ;
ARISAWA, J ;
KOZUKA, T .
JOURNAL OF DIGITAL IMAGING, 1995, 8 (01) :31-36
[6]   IMAGE QUALITY OF A DIGITAL CHEST RADIOGRAPHY SYSTEM BASED ON A SELENIUM DETECTOR [J].
NEITZEL, U ;
MAACK, I ;
GUNTHERKOHFAHL, S .
MEDICAL PHYSICS, 1994, 21 (04) :509-516
[7]   Selenium-based digital radiography versus conventional film-screen radiography of the hands and feet: A subjective comparison [J].
Piraino, DW ;
Davros, WJ ;
Lieber, M ;
Richmond, BJ ;
Schils, JP ;
Recht, MP ;
Grooff, PN ;
Belhobek, GH .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 172 (01) :177-184
[8]   Chest radiography [J].
Ravin, CE ;
Chotas, HG .
RADIOLOGY, 1997, 204 (03) :593-600
[9]   THE USE OF CONTINUOUS AND DISCRETE CONFIDENCE JUDGMENTS IN RECEIVER OPERATING CHARACTERISTIC STUDIES OF DIAGNOSTIC-IMAGING TECHNIQUES [J].
ROCKETTE, HE ;
GUR, D ;
METZ, CE .
INVESTIGATIVE RADIOLOGY, 1992, 27 (02) :169-172
[10]   DIGITAL STORAGE PHOSPHOR IMAGING VERSUS CONVENTIONAL FILM RADIOGRAPHY IN CT-DOCUMENTED CHEST DISEASE [J].
SCHAEFER, CM ;
GREENE, R ;
OESTMANN, JW ;
HALL, DA ;
LLEWELLYN, HJ ;
MCCARTHY, KA ;
PILESPELLMAN, ER ;
RUBENS, JR .
RADIOLOGY, 1990, 174 (01) :207-210