Capillary Electrophoresis-Electrospray Ionization-Mass Spectrometry for Quantitative Analysis of Glycans Labeled with Multiplex Carbonyl-Reactive Tandem Mass Tags

被引:76
|
作者
Zhong, Xuefei [1 ]
Chen, Zhengwei [2 ]
Snovida, Sergei [3 ]
Liu, Yan [4 ]
Rogers, John C. [3 ]
Li, Lingjun [1 ,2 ]
机构
[1] Univ Wisconsin, Sch Pharm, Madison, WI 53705 USA
[2] Univ Wisconsin, Dept Chem, Madison, WI 53706 USA
[3] Thermo Fisher Sci, Thermo Sci Pierce Prot Res, Rockford, IL 61105 USA
[4] Xiamen Univ, Sch Chem & Chem Engn, Xiamen 361005, Peoples R China
关键词
N-LINKED GLYCANS; PROTEIN GLYCOSYLATION; LIQUID-CHROMATOGRAPHY; HIGH-SENSITIVITY; STRUCTURAL-CHARACTERIZATION; INDUCED FLUORESCENCE; ION MOBILITY; GLYCOMICS; QUANTIFICATION; IDENTIFICATION;
D O I
10.1021/acs.analchem.5b01835
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Recently developed carbonyl-reactive aminoxy tandem mass tag (aminoxyTMT) reagents enable multiplexed characterization and quantitative comparison of structurally complex glycans between different biological samples. Compared to some previously reported isotopic labeling strategies for glycans, the use of the aminoxyTMT method features a simple labeling procedure, excellent labeling efficiency, and reduced spectral complexity at the MS' level. Presence of the tertiary amine functionality in the reporter region of the aminoxyTMT labels leads to increased ionization efficiency of the labeled glycans thus improving electrospray ionization (ESI)-mass spectrometry (MS) detection sensitivity. The use of the labeling reagent also makes electrophoretic separation of the labeled neutral and acidic glycans feasible. In this work, we characterized the ESI and collision induced dissociation (CID) behavior of the aminoxyTMT-labeled neutral and sialylated glycans. For the high-mannose N-glycans and small sialylated oligosaccharides, CID fragmentation of [M + Na + H](2+) provides the most informative MS2 spectra for both quantitative and qualitative analysis. For complex N-glycans, MS3 of the protonated Y-1(H) ion can be used for relative quantification without interference from the HexNAc fragments. Online capillary electrophoresis (CE)-ESI-MS/MS analyses of multiplexed aminoxyTMT-labeled human milk oligosaccharides (HMOs) and different types of N-glycans released from glycoprotein standards were demonstrated. Improved resolution and quantification accuracy of the labeled HMO isomers was achieved by coupling CE with traveling wave ion mobility (TWIM)-CID-MS/MS. N-Glycans released from human serum protein digests were labeled with six-plex aminoxyTMT and subjected to CE-ESI-MS/pseudo-MS3 analysis, which demonstrated the potential utility of this glycan relative quantification platform for more complex biological samples.
引用
收藏
页码:6527 / 6534
页数:8
相关论文
共 50 条
  • [21] Validation of chiral capillary electrophoresis-electrospray ionization-mass spectrometry methods for ecstasy and methadone in plasma
    Schappler, Julie
    Guillarme, Davy
    Prat, Josiane
    Veuthey, Jean-Luc
    Rudaz, Serge
    ELECTROPHORESIS, 2008, 29 (10) : 2193 - 2202
  • [22] Metabolic Differentiation of Neuronal Phenotypes by Single-cell Capillary Electrophoresis-Electrospray Ionization-Mass Spectrometry
    Nemes, Peter
    Knolhoff, Ann M.
    Rubakhin, Stanislav S.
    Sweedler, Jonathan V.
    ANALYTICAL CHEMISTRY, 2011, 83 (17) : 6810 - 6817
  • [23] Microchip capillary electrophoresis-electrospray ionization-mass spectrometry of intact proteins using uncoated Ormocomp microchips
    Sikanen, Tiina
    Aura, Susanna
    Franssila, Sami
    Kotiaho, Tapio
    Kostiainen, Risto
    ANALYTICA CHIMICA ACTA, 2012, 711 : 69 - 76
  • [24] Determination of Glyphosate as cross-contaminant in a commercial herbicide by capillary electrophoresis-electrospray ionization-mass spectrometry
    Safarpour, H
    Asiaie, R
    ELECTROPHORESIS, 2005, 26 (7-8) : 1562 - 1566
  • [25] Performance of a sheathless porous tip sprayer for capillary electrophoresis-electrospray ionization-mass spectrometry of intact proteins
    Haselberg, Rob
    Ratnayake, Chitra K.
    de Jong, Gerhardus J.
    Somsen, Govert W.
    JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (48) : 7605 - 7611
  • [26] Highly Sensitive and Robust Capillary Electrophoresis-Electrospray Ionization-Mass Spectrometry: Interfaces, Preconcentration Techniques and Applications
    Wu, Huanming
    Tang, Keqi
    REVIEWS IN ANALYTICAL CHEMISTRY, 2020, 39 (01) : 45 - 55
  • [27] On-line capillary electrophoresis-electrospray ionization mass spectrometry analysis of urinary porphyrins
    Li, Jinhua
    Chan, Wan
    Cai, Zongwei
    ELECTROPHORESIS, 2009, 30 (10) : 1790 - 1797
  • [28] Virtual Quantification of Metabolites by Capillary Electrophoresis-Electrospray Ionization-Mass Spectrometry: Predicting Ionization Efficiency Without Chemical Standards
    Chalcraft, Kenneth R.
    Lee, Richard
    Mills, Casandra
    Britz-McKibbin, Philip
    ANALYTICAL CHEMISTRY, 2009, 81 (07) : 2506 - 2515
  • [29] Hybrid Capillary/Microfluidic System for Comprehensive Online Liquid Chromatography-Capillary Electrophoresis-Electrospray Ionization-Mass Spectrometry
    Mellors, J. Scott
    Black, William A.
    Chambers, Andrew G.
    Starkey, Jason A.
    Lacher, Nathan A.
    Ramsey, J. Michael
    ANALYTICAL CHEMISTRY, 2013, 85 (08) : 4100 - 4106
  • [30] Analysis of fluorescently labeled oligosaccharides by capillary electrophoresis and electrospray ionization mass spectrometry
    Wolff, MW
    Bazin, HG
    Lindhardt, RJ
    BIOTECHNOLOGY TECHNIQUES, 1999, 13 (11) : 797 - 801