Development of deep-UV sensitive MPPC for liquid xenon scintillation detector

被引:17
|
作者
Ootani, W. [1 ]
Ieki, K. [2 ]
Iwamoto, T. [1 ]
Kaneko, D. [1 ]
Mori, T. [1 ]
Nakaura, S. [1 ]
Nishimura, M. [1 ]
Ogawa, S. [1 ]
Sawada, R. [1 ]
Shibata, N. [1 ]
Uchiyama, Y. [1 ]
Yoshida, K. [1 ]
Sato, K. [3 ]
Yamada, R. [3 ]
机构
[1] Univ Tokyo, ICEPP, Tokyo 1130033, Japan
[2] Paul Scherrer Inst, CH-5232 Villigen, Switzerland
[3] Hamamatsu Photon KK, Div Solid State, Hamamatsu, Shizuoka 4358558, Japan
来源
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT | 2015年 / 787卷
关键词
MPPC; SiPM; Liquid xenon; VUV light;
D O I
10.1016/j.nima.2014.12.007
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The liquid xenon (LXe) gamma-ray detector for the MEG II experiment is based on a highly granular scintillation readout with Multi Pixel Photon Counters (MPPCs). Here we report on the development of a large area MPPC sensitive to LXe scintillation light in deep -UV range for the MEG II LXe detector. A prototype model of the deep -UV MPPC with an active area of 12 x 12 mm2 was successfully tested in LXe LXe, showing an excellent performance such as a high photon detection efficiency for the LXe scintillation light (about 207 at Delta V = 2.5 V), a high internal gain (about 10(6) at Delta V = 2.5 V) and an excellent single photoelectron resolution. The sensor chip of the MPPC is segmented into four sectors, which arc then connected in series in order to reduce the overall sensor capacitance. The signal fall time of about 135 ns for the non segmented sensor was significantly reduced down to 25 ns with the series connected sensor segments. The preliminary results on the performance of the deep DV MPPC arc presented. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:220 / 223
页数:4
相关论文
共 50 条
  • [11] Performance of the Liquid Xenon Scintillation Detector for the MEG Experiment
    Ootani, W.
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 940 - 942
  • [12] A Sensitive and Portable Deep-UV Absorbance Detector with a Microliter Gas Cell Compatible with Micro GC
    Khan, Sulaiman
    Newport, David
    Le Calve, Stephane
    CHEMOSENSORS, 2021, 9 (04)
  • [13] Design and test of deep-UV position sensitive detectors
    Mazzeo, G
    Salvatori, S
    Ralchenko, V
    Conte, G
    PROCEEDINGS OF THE IEEE SENSORS 2004, VOLS 1-3, 2004, : 1554 - 1557
  • [14] DETECTING DARK MATTER USING A LIQUID XENON SCINTILLATION DETECTOR
    BELLI, P
    BERNABEI, R
    DANGELO, S
    INCICCHITTI, A
    PROSPERI, D
    NUOVO CIMENTO DELLA SOCIETA ITALIANA DI FISICA A-NUCLEI PARTICLES AND FIELDS, 1990, 103 (05): : 767 - 771
  • [15] A NEW LIQUID XENON SCINTILLATION DETECTOR FOR POSITRON EMISSION TOMOGRAPHY
    CHEPEL, VY
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1993, 21 (01): : 47 - 51
  • [16] Deep-UV Detector for HPLC with Light-Emitting Diode
    Schmid, Stefan
    Macka, Mirek
    Hauser, Peter C.
    CHIMIA, 2008, 62 (10) : 860 - 860
  • [17] Application of Scintillation in Helium Mixed with Xenon to a Position-Sensitive Detector
    Saito, K.
    Sasaki, S.
    Tawara, H.
    Shibamura, E.
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 14 - 18
  • [18] Nanoscale structure study of boron nitride nanosheets and development of a deep-UV photo-detector
    Sajjad, Muhammad
    Jadwisienczak, Wojciech M.
    Feng, Peter
    NANOSCALE, 2014, 6 (09) : 4577 - 4582
  • [19] Absorption of scintillation light in a 1001 liquid xenon γ-ray detector and expected detector performance
    Baldini, A
    Bemporad, C
    Cei, F
    Doke, T
    Grassi, M
    Grebenuk, AA
    Grigoriev, DN
    Haruyama, T
    Kasami, K
    Kikuchi, J
    Maki, A
    Mashimo, T
    Mihara, S
    Mitsuhashi, T
    Mori, T
    Nicoló, D
    Nishiguchi, H
    Ootani, W
    Ozone, K
    Papa, A
    Pazzi, R
    Ritt, S
    Sawada, R
    Sergiampietri, F
    Signorelli, G
    Suzuki, S
    Terasawa, K
    Yamashita, M
    Yamashita, S
    Yoshimura, T
    Yuri, Y
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 545 (03): : 753 - 764
  • [20] Development for deep-UV & excimer pellicle (membrane longevity)
    Kashiwagi, M
    Matsuzaki, H
    Nakayama, N
    PHOTOMASK AND X-RAY MASK TECHNOLOGY III, 1996, 2793 : 372 - 386