A sensitive amperometric immunosensor for hepatitis B surface antigen based on biocompatible redox-active chitosan-toluidine blue/gold nanoparticles composite film

被引:7
作者
Liang, Ruping
Chen, Yunxia
Qiu, Jianding [1 ]
机构
[1] Nanchang Univ, Dept Chem, Nanchang 330031, Peoples R China
基金
中国国家自然科学基金;
关键词
DEPOSITED NANOCOMPOSITE FILM; ELECTRON-TRANSFER; ELECTROCHEMICAL IMMUNOASSAY; GOLD NANOPARTICLES; IMMOBILIZATION; BIOSENSOR; ENZYME; DERIVATIVES; ANTIBODIES; STRATEGY;
D O I
10.1039/c0ay00774a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel amperometric immunosensor has been developed by self-assembling gold nanoparticles (Au NPs) onto a toluidine blue-branched chitosan (CHIT-TB) modified electrode for the sensitive determination of hepatitis B surface antigen (HBsAg) as a model protein. The formation of CHIT-TB composite film not only effectively avoids the leakage of TB and retains its electrochemical activity, but also enhances the conductivity and charge-transport properties of the composite. Further adsorption of Au NPs into the CHIT matrix provides both the interactive sites for the immobilization of HBsAb and a favorable microenvironment to maintain the activity of the HBsAb, in addition it prevents leakage of HBsAb molecules from the CHIT-TB/Au NPs/HBsAb film structure efficiently. The morphologies and electrochemistry of the formed nanocomposite film were investigated by using scanning electron microscopy and electrochemical techniques including cyclic voltammetry and electrochemical impedance spectroscopy (EIS). The HBsAg concentration was measured through the decrease of amperometric responses in the corresponding specific binding of antigen and antibody. The decreased voltametric values were proportional to the HBsAg concentration in the range of 1 to 200 ng mL(-1). The detection of HBsAg levels in five sera obtained from a hospital showed acceptable accuracy.
引用
收藏
页码:1338 / 1343
页数:6
相关论文
共 35 条
[1]   Glucose biosensing based on the highly efficient immobilization of glucose oxidase on a Prussian blue modified nanostructured Au surface [J].
Ahmadalinezhad, Asieh ;
Kafi, A. K. M. ;
Chen, Aicheng .
ELECTROCHEMISTRY COMMUNICATIONS, 2009, 11 (10) :2048-2051
[2]   Double-codified gold nanolabels for enhanced immunoanalysis [J].
Ambrosi, Adriano ;
Castaneda, Maria Teresa ;
Killard, Anthony J. ;
Smyth, Malcolm R. ;
Alegret, Salvador ;
Merkoci, Arben .
ANALYTICAL CHEMISTRY, 2007, 79 (14) :5232-5240
[3]   Flow-Mediated Arterial Dilation in Primary Antiphospholipid Syndrome [J].
Bilora, Franca ;
Sartori, Maria Teresa ;
Zanon, Ezio ;
Campagnolo, Enrico ;
Arzenton, Marianna ;
Rossato, Alberto .
ANGIOLOGY, 2009, 60 (01) :104-107
[4]   Electrochemical immunoassay of human chorionic gonadotrophin based on its immobilization in gold nanoparticles-chitosan membrane [J].
Chen, J ;
Yan, F ;
Du, D ;
Wu, J ;
Ju, HX .
ELECTROANALYSIS, 2006, 18 (07) :670-676
[5]   A new enzyme immobilization technique based on thionine-bovine serum albumin conjugate and gold colloidal nanoparticles for reagentless amperometric biosensor applications [J].
Chen, Shihong ;
Yuan, Ruo ;
Chai, Yaqin ;
Li, Na .
ELECTROANALYSIS, 2008, 20 (04) :418-425
[6]   Electrochemical immunosensor using p-aminophenol redox cycling by hydrazine combined with a low background current [J].
Das, Jagotamoy ;
Jo, Kyungmin ;
Lee, Jae Wook ;
Yang, Haesik .
ANALYTICAL CHEMISTRY, 2007, 79 (07) :2790-2796
[7]   Gold nanoparticle-based electrochemical magnetoimmunosensor for rapid detection of anti-hepatitis B virus antibodies in human serum [J].
de la Escosura-Muniz, Alfredo ;
Maltez-da Costa, Marisa ;
Sanchez-Espinel, Christian ;
Diaz-Freitas, Belen ;
Fernandez-Suarez, Jonathan ;
Gonzalez-Fernandez, Africa ;
Merkoci, Arben .
BIOSENSORS & BIOELECTRONICS, 2010, 26 (04) :1710-1714
[8]   Electrochemical immunoassay of hepatitis B surface antigen by the amplification of gold nanoparticles based on the nanoporous gold electrode [J].
Ding, Caifeng ;
Li, Hui ;
Hu, Kongcheng ;
Lin, Jin-Ming .
TALANTA, 2010, 80 (03) :1385-1391
[9]   Intramolecular electron transfer within a water-soluble, ferrocene-labeled polyacrylate [J].
Hatozaki, O ;
Anson, FC .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1997, 420 (1-2) :195-199
[10]   Construction of amperometric immunosensors based on the electrogeneration of a permeable biotinylated polypyrrole film [J].
Ionescu, RE ;
Gondran, C ;
Gheber, LA ;
Cosnier, S ;
Marks, RS .
ANALYTICAL CHEMISTRY, 2004, 76 (22) :6808-6813