Prediction of early-onset atrial tachyarrhythmia after successful trans-catheter device closure of atrial septal defect

被引:10
|
作者
Park, Kyoung-Min [1 ]
Hwang, Jin Kyung [1 ]
Chun, Kwang Jin [1 ]
Park, Seung-Jung [1 ]
On, Young Keun [1 ]
Kim, June Soo [1 ]
Park, Seung Woo [1 ]
Kang, I-Seok [2 ]
Song, Jinyoung [2 ]
Huh, June [2 ]
机构
[1] Sungkyunkwan Univ, Sch Med, Samsung Med Ctr, Div Cardiol,Dept Med, Seoul, South Korea
[2] Sungkyunkwan Univ, Sch Med, Samsung Med Ctr, Grown Up Congenital Heart Dis Clin,Dept Pediat,He, Seoul, South Korea
关键词
atrial fibrillation; atrial septal defect; transcatheter closure; TRANSCATHETER CLOSURE; LONG-TERM; FOLLOW-UP; SURGICAL CLOSURE; FIBRILLATION; ARRHYTHMIAS; CHILDREN; STROKE; REPAIR; AGE;
D O I
10.1097/MD.0000000000004706
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Atrial tachyarrhythmia is a well-known long-term complication of atrial septal defect (ASD) in adults, even after successful trans-catheter closure. However, the risk factors for early-onset atrial tachyarrhythmia after trans-catheter closure remain unclear. This retrospective study enrolled adults with secundum ASD undergoing trans-catheter closure from January 2000 to March 2014. We analyzed the clinical characteristics of patients and assessed risk factors for new-onset atrial tachyarrhythmia defined as a composite of atrial fibrillation or flutter (AF/AFL) after ASD closure. We enrolled a total of 427 patients; 123 were male (28.8%) and the median age was 37.0 (interquartile range [IQR]: 18.3-49.0). Nineteen (4.4%) patients had documented atrial tachyarrhythmia during the follow-up period (median: 11.4 months [IQR: 5.4-24]). Patients with transient AF/AFL during closure showed a greater incidence of new-onset atrial tachyarrhythmia during the follow-up period than patients with consistent sinus rhythm during closure (27.3% vs 3.8%; P=0.01). Most new-onset atrial tachyarrhythmias were documented within 6 months (median: 2.6 [IQR: 1.2-4.1] months) of closure. In the multivariate analysis, the risk for new-onset atrial tachyarrhythmia was significant in patients with AF/AFL during closure (hazard ratio [HR]: 9.90, 95% confidence interval [CI]: 2.86-34.20; P<0.001), deficient posteroinferior rim (HR: 5.48, 95% CI: 1.15-25.72; P=0.04), and age of closure over 48 years (HR: 3.30, 95% CI: 1.30-8.38; P=0.01). In conclusion, transient AF/AFL during trans-catheter closure of ASD as well as deficient posteroinferior rim and age of closure over 48 years may be useful for predicting early new-onset atrial tachyarrhythmia after device closure.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Successful closure of a very large secundum atrial septal defect with the Occlutech Figulla® device
    Tasal, Abdurrahman
    Bacaksiz, Ahmet
    Erdogan, Ercan
    Sonmez, Osman
    POSTEPY W KARDIOLOGII INTERWENCYJNEJ, 2012, 8 (04): : 347 - 350
  • [22] New-onset headache after percutaneous atrial septal defect closure
    Gangopadhyay, Debasree
    Roy, Mahua
    ANNALS OF PEDIATRIC CARDIOLOGY, 2022, 15 (05) : 489 - 492
  • [23] Device closure of atrial septal defect: medium-term outcome with special reference to complications
    Sadiq, Masood
    Kazmi, Tehmina
    Rehman, Asif U.
    Latif, Farhan
    Hyder, Najam
    Qureshi, Shakeel A.
    CARDIOLOGY IN THE YOUNG, 2012, 22 (01) : 71 - 78
  • [24] Predictors of New-Onset Atrial Tachyarrhythmias After Transcatheter Atrial Septal Defect Closure in Adults
    Miura, Kotaro
    Kimura, Mai
    Anzai, Atsushi
    Arai, Takahide
    Kawakami, Takashi
    Yuasa, Shinsuke
    Hayashida, Kentaro
    Endo, Jin
    Tsuruta, Hikaru
    Itabashi, Yuji
    Kawamura, Akio
    Fukuda, Keiichi
    Kanazawa, Hideaki
    HEART LUNG AND CIRCULATION, 2021, 30 (09) : 1406 - 1413
  • [25] Predictors of pulmonary hypertension after atrial septal defect closure: Impact of atrial fibrillation
    Celik, Mehmet
    Yilmaz, Yusuf
    Kup, Ayhan
    Kahyaoglul, Muzaffer
    Karagoz, Ali
    Ozdemir, Nihal
    Kaymaz, Cihangir
    Kirali, Mehmet Kaan
    TURK GOGUS KALP DAMAR CERRAHISI DERGISI-TURKISH JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2022, 30 (03): : 344 - 353
  • [26] Early Complications After Percutaneous Closure of Atrial Septal Defect in Infants with Procedural Weight Less than 15 kg
    Tanghoj, Gustaf
    Odermarsky, Michal
    Naumburg, Estelle
    Liuba, Petru
    PEDIATRIC CARDIOLOGY, 2017, 38 (02) : 255 - 263
  • [27] Study of atrial arrhythmias after surgical or device closure of atrial septal defect
    Mohankumar, Nandhini
    Namboodiri, Narayanan
    Nair, Krishna Kumar Mohanan
    Raghuram, Karthik
    Valaparambil, Ajitkumar
    Mahadevan, Krishnamoorthy Kavassery
    NATIONAL MEDICAL JOURNAL OF INDIA, 2022, 35 (05): : 271 - 275
  • [28] Incidence and Predictors of Aggravation of Mitral Regurgitation After Atrial Septal Defect Closure
    Nishimura, Shunsuke
    Izumi, Chisato
    Amano, Masashi
    Miyake, Makoto
    Tamura, Toshihiro
    Kondo, Hirokazu
    Kaitani, Kazuaki
    Yamanaka, Kazuo
    Nakagawa, Yoshihisa
    ANNALS OF THORACIC SURGERY, 2017, 104 (01) : 205 - 210
  • [29] Late-onset aortic regurgitation after device closure of atrial septal defect
    Prasad, Pooja
    Singh, Tania
    Dharan, Baiju S.
    Gopalakrishnan, Arun
    Krishnamoorthy, Kavassery Mahadevan
    ANNALS OF PEDIATRIC CARDIOLOGY, 2024, 17 (04) : 301 - 303
  • [30] A Biodegradable Device (BioSTAR™) for Atrial Septal Defect Closure in Children
    Morgan, Gareth
    Lee, Kyong-Jin
    Chaturvedi, Rajiv
    Benson, Lee
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2010, 76 (02) : 241 - 245