Serum discrimination of early-stage lung cancer patients using electrospray-ionization mass spectrometry

被引:22
|
作者
Hocker, James R. [1 ]
Peyton, Marvin D. [2 ]
Lerner, Megan R. [2 ,3 ]
Mitchell, Stephanie L. [2 ,3 ]
Lightfoot, Stan A. [3 ]
Lander, Theresa J. [2 ,3 ]
Bates-Albers, Leah M. [1 ]
Vu, Nicole T. [4 ]
Hanas, Rushie J. [1 ]
Kupiec, Thomas C. [4 ]
Brackett, Daniel J. [2 ,3 ]
Hanas, Jay S. [1 ,2 ,3 ]
机构
[1] Univ Oklahoma, Hlth Sci Ctr, Dept Biochem & Mol Biol, Oklahoma City, OK 73104 USA
[2] Univ Oklahoma, Hlth Sci Ctr, Dept Surg, Oklahoma City, OK 73104 USA
[3] Vet Affairs Med Ctr, Oklahoma City, OK 73104 USA
[4] Analyt Res Labs BioPharma, Oklahoma City, OK 73104 USA
关键词
Lung cancer; Serum profiling; Electrospray-ionization; Mass spectrometry; Non-small cell lung carcinoma; Early detection; OVARIAN-CANCER; IDENTIFICATION; BIOMARKERS; PROTEOMICS; DISCOVERY;
D O I
10.1016/j.lungcan.2011.03.014
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
The goal of this study was to evaluate the usefulness of electrospray ionization-mass spectrometry (ESI-MS) technology to distinguish sera of early-stage lung cancer patients from control individuals. ESI-MS m/z (mass divided by charge) data were generated from sera of 43 non-small cell lung cancer patients (pathological stages I and II) and 21 control individuals. Identifications of m/z peak area significances between cancer and control ESI-MS sera spectra were performed using t-tests. A "leave one out" cross validation procedure, which mimics blinded sera analysis and corrects for "over-fitting" of data, yielded discriminatory cancer versus control distribution p value and ROC curve area value of < 0.001 and 0.87, respectively. Analysis without the "leave one out" cross validation procedure yielded a ROC curve area of 0.99 for discrimination of sera from lung cancer patients versus control individuals. Predictive value measurements revealed overall test efficiency and sensitivity for distinguishing sera from lung cancer patients from controls (using "leave one out" cross validation) of 80% and 84%, respectively. ESI-MS serum analysis between control individuals and lung cancer patients who smoked or did not smoke had p values in ranges indicating that smoking effects are not pronounced in our analysis. These studies indicate that ESI-MS analyses of sera from early stage non-small cell lung cancer patients were helpful in distinguishing these patients from control individuals. (C) 2011 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:206 / 211
页数:6
相关论文
共 50 条
  • [21] Electrospray-ionization time-of-flight mass spectrometry: pH-dependence of phosphotungstate species
    Easterly, CE
    Hercules, DM
    Houalla, M
    APPLIED SPECTROSCOPY, 2001, 55 (12) : 1665 - 1670
  • [22] Serum metabolic profiling study of endometriosis by using wooden-tip electrospray ionization mass spectrometry
    Yang, Bi-cheng
    Liu, Fa-ying
    Wang, Li-qun
    Zou, Yang
    Wang, Feng
    Deng, Wei
    Wan, Xi-di
    Yang, Xiao
    He, Ming
    Huang, Ou-ping
    ANALYTICAL METHODS, 2015, 7 (15) : 6125 - 6132
  • [23] STRUCTURAL ELUCIDATION OF UNDERIVATIZED GANGLIOSIDES BY ELECTROSPRAY-IONIZATION TANDEM MASS-SPECTROMETRY (ESIMS/MS)
    II, T
    OHASHI, Y
    NAGAI, Y
    CARBOHYDRATE RESEARCH, 1995, 273 (01) : 27 - 40
  • [24] Electrospray-ionization time-of-flight mass spectrometry: pH-dependence of phosphomolybdate species
    Easterly, CE
    Hercules, DM
    Houalla, M
    APPLIED SPECTROSCOPY, 2001, 55 (12) : 1671 - 1675
  • [25] Evidence for an essential role of intradimer interaction in catalytic function of carnosine dipeptidase II using electrospray-ionization mass spectrometry
    Okumura, Nobuaki
    Tamura, Jun
    Takao, Toshifumi
    PROTEIN SCIENCE, 2016, 25 (02) : 511 - 522
  • [26] Early detection of unilateral ureteral obstruction by desorption electrospray ionization mass spectrometry
    Banerjee, Shibdas
    Wong, Anny Chuu-Yun
    Yan, Xin
    Wu, Bo
    Zhao, Hongjuan
    Tibshirani, Robert J.
    Zare, Richard N.
    Brooks, James D.
    SCIENTIFIC REPORTS, 2019, 9 (1)
  • [27] Detection of lung cancer using plasma protein profiling by matrix-assisted laser desorption/ionization mass spectrometry
    Shevchenko, Valeriy E.
    Arnotskaya, Natalia E.
    Zaridze, David G.
    EUROPEAN JOURNAL OF MASS SPECTROMETRY, 2010, 16 (04) : 539 - 549
  • [28] DEUTERIUM-EXCHANGE OF ALPHA-HELICES AND BETA-SHEETS AS MONITORED BY ELECTROSPRAY-IONIZATION MASS-SPECTROMETRY
    WAGNER, DS
    MELTON, LG
    YAN, YB
    ERICKSON, BW
    ANDEREGG, RJ
    PROTEIN SCIENCE, 1994, 3 (08) : 1305 - 1314
  • [29] Serum proteomics profiling identifies a preliminary signature for the diagnosis of early-stage lung cancer
    Gasparri, Roberto
    Noberini, Roberta
    Cuomo, Alessandro
    Yadav, Avinash
    Tricarico, Davide
    Salvetto, Carola
    Maisonneuve, Patrick
    Caminiti, Valentina
    Sedda, Giulia
    Sabalic, Angela
    Bonaldi, Tiziana
    Spaggiari, Lorenzo
    PROTEOMICS CLINICAL APPLICATIONS, 2023, 17 (02)
  • [30] Structural characterization of a series of 10-carbon sugar derivatives by electrospray-ionization MSn mass spectrometry
    Zou, DP
    Cao, SX
    Xu, WC
    Liu, HM
    CARBOHYDRATE RESEARCH, 2005, 340 (15) : 2411 - 2421