Clinical step onward with X-ray dark-field imaging and perspective view of medical applications of synchrotron radiation in Japan

被引:22
|
作者
Ando, M
Hashimoto, E
Hashizume, H
Hyodo, K
Inoue, H
Kunisada, T
Maksimenko, A
Mori, K
Rubenstein, E
Roberson, J
Shimao, D
Sugiyama, H
Takeda, K
Toyofuku, F
Ueno, E
Umetani, K
Wada, H
Pattanasiriwisawa, W
机构
[1] Natl Lab High Energy Phys, KEK, Photon Factory, Tsukuba, Ibaraki 3050801, Japan
[2] GUAS, Dept Photo Sci, Sch Adv Studies, Tsukuba, Ibaraki 3050801, Japan
[3] GUAS, Dept Mat Struct Sci, Sch High Energy Accelerator Sci, Tsukuba, Ibaraki 3050801, Japan
[4] Okayama Univ, Grad Sch Med & Dent, Study Biofunct Recovery & Reconstruct Plast & Rec, Okayama 7008558, Japan
[5] Stanford Univ, Sch Med, Dept Med, Stanford, CA 94305 USA
[6] Calif Ear Inst, Palo Alto, CA 94304 USA
[7] Kyushu Univ, Sch Hlth Sci, Fac Med, Higashi Ku, Fukuoka 8128582, Japan
[8] Univ Tsukuba, Dept Breast Tyroid Endocrine Surg, Inst Clin Med, Tsukuba, Ibaraki 3058571, Japan
[9] JASRI, Sayo, Hyogo 6795198, Japan
[10] Tohoku Univ, Dept Biorobot, Sch Engn, Sendai, Miyagi 9808579, Japan
[11] Suranaree Univ Technol, Dept Phys, Nakhon Ratchasima 30000, Thailand
[12] Ibaraki Prefectural Univ Hlth Sci, Dept Radiol Sci, Inashiki, Ibaraki 3000394, Japan
来源
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT | 2005年 / 548卷 / 1-2期
关键词
SPring-8; KEK; photon factory; synchrotron radiation; clinical application; X-ray dark-field imaging; monochrocollimator; laue diffraction filter; refraction; pseudoclinical diagnosis; excised human femoral head; articular;
D O I
10.1016/j.nima.2005.03.059
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
This paper reports, the application of synchrotron radiation to basic medicine at SPring-8 involving instrumentation and medical application of imaging and scattering. Emphasis should be laid on X-ray dark-field imaging (DFI) whose goal is clinical diagnosis of organs that have been invisible by ordinary techniques. Development of this technique is under way both at SPring-8 and KEK. The X-ray optics of DFI comprises a Bragg asymmetric monochro-collimator and a Lane case analyzer with a diffraction index of 4 4 0 using the X-ray energy of 35 keV (lambda = 0.0354 nm) in a parallel position. This analyzer that can provide with 80 mm x 80 mm view size has 2.15 mm thickness. At present the spatial resolution is around 5-10 mu m. Visibility of some organs such as soft bone tissue at excised human femoral head and breast cancer tissue is under test. This preliminary test shows that the DFI seems feasible in clinical diagnosis. Furthermore, a perspective view of application of synchrotron radiation to clinical medicine in Japan will be given. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:1 / 16
页数:16
相关论文
共 50 条
  • [1] Radiation furnace for synchrotron dark-field x-ray microscopy experiments
    Yildirim, C.
    Vitoux, H.
    Dresselhaus-Marais, L. E.
    Steinmann, R.
    Watier, Y.
    Cook, P. K.
    Kutsal, M.
    Detlefs, C.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2020, 91 (06):
  • [2] Directional x-ray dark-field imaging
    Jensen, Torben H.
    Bech, Martin
    Bunk, Oliver
    Donath, Tilman
    David, Christian
    Feidenhans'i, Robert
    Pfeiffer, Franz
    PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (12): : 3317 - 3323
  • [3] Dark-field hyperspectral X-ray imaging
    Egan, Christopher K.
    Jacques, Simon D. M.
    Connolley, Thomas
    Wilson, Matthew D.
    Veale, Matthew C.
    Seller, Paul
    Cernik, Robert J.
    PROCEEDINGS OF THE ROYAL SOCIETY A-MATHEMATICAL PHYSICAL AND ENGINEERING SCIENCES, 2014, 470 (2165):
  • [4] X-ray dark-field imaging modeling
    Cong, W.
    Pfeiffer, F.
    Bech, M.
    Wang, G.
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2012, 29 (06) : 908 - 912
  • [5] Development of X-ray dark-field imaging towards clinical application
    ANDO Masami
    HASHIMOTO Eiko
    HASHIZUME Hiroyuki
    HYODO Kazuyuki
    INOUE Hajime
    ISHIKAWA Tetsuya
    KUNISADA Toshiyuki
    MAKSIMENKO Anton
    PATTANASIRIWISAWA Wanwisa
    RUBENSTEIN Edward
    ROBERSON Joseph
    SHIMAO Daisuke
    SUGIYAMA Hiroshi
    TAKEDA Ken
    UENO Ei
    WADA Hiroshi
    NuclearScienceandTechniques, 2004, (03) : 129 - 139
  • [6] X-ray Dark-Field Imaging and potential of its clinical application
    Shimao, D
    Sugiyama, H
    Kunisada, T
    Maksimenko, A
    Toyofuku, F
    Ueno, E
    Yamasaki, K
    Obayashi, C
    Hyodo, K
    Li, G
    Pan, L
    Jiang, XM
    Ando, M
    Medical Imaging 2005: Physics of Medical Imaging, Pts 1 and 2, 2005, 5745 : 32 - 39
  • [7] Energy weighted x-ray dark-field imaging
    Pelzer, Georg
    Zang, Andrea
    Anton, Gisela
    Bayer, Florian
    Horn, Florian
    Kraus, Manuel
    Rieger, Jens
    Ritter, Andre
    Wandner, Johannes
    Weber, Thomas
    Fauler, Alex
    Fiederle, Michael
    Wong, Winnie S.
    Campbell, Michael
    Meiser, Jan
    Meyer, Pascal
    Mohr, Juergen
    Michel, Thilo
    OPTICS EXPRESS, 2014, 22 (20): : 24507 - 24515
  • [8] Signal decomposition for X-ray dark-field imaging
    Pattern Recognition Lab, Friedrich-Alexander-University Erlangen-Nuremberg, Erlangen, Germany
    不详
    不详
    Kaeppler, Sebastian, 1600, Springer Verlag (8673):
  • [9] Signal Decomposition for X-ray Dark-Field Imaging
    Kaeppler, Sebastian
    Bayer, Florian
    Weber, Thomas
    Maier, Andreas
    Anton, Gisela
    Hornegger, Joachim
    Beckmann, Matthias
    Fasching, Peter A.
    Hartmann, Arndt
    Heindl, Felix
    Michel, Thilo
    Oezguel, Gueluemser
    Pelzer, Georg
    Rauh, Claudia
    Rieger, Jens
    Schulz-Wendtland, Ruediger
    Uder, Michael
    Wachter, David
    Wenkel, Evelyn
    Riess, Christian
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2014, PT I, 2014, 8673 : 170 - +
  • [10] Development of a soft x-ray dark-field imaging microscope
    Takano, H
    Aoki, S
    X-RAY MICROSCOPY, PROCEEDINGS, 2000, 507 : 55 - 59