Reliability of ground reaction forces in the aquatic environment

被引:7
作者
Tavares Barreto, Maria Simone [1 ]
Dela Bela, Lais Faganello [1 ]
Dias, Josilainne Marcelino [1 ]
Marcondes Pelegrinelli, Alexandre Roberto [1 ]
de Campos, Renata Rosa [1 ]
da Silva Carvalho, Rodrigo Gustavo [1 ,2 ]
Taglietti, Marcelo [1 ,3 ]
Batista, Joao Pedro, Jr. [1 ,4 ]
Silva, Mariana Felipe [1 ]
Olkoski, Mabel Micheline [1 ]
Nogueira, Jessyca Fernandes [1 ]
de Souza, Daniella Carneiro [1 ]
McVeigh, Joseph Gerald [5 ]
Moura, Felipe Arruda [6 ]
Facci, Ligia Maria [1 ,7 ]
Cardoso, Jefferson Rosa [1 ,7 ]
机构
[1] Univ Estadual Londrina, PAIFIT Res Grp, Lab Biomech & Clin Epidemiol, Av Robert Kock 60, BR-86038440 Londrina, PR, Brazil
[2] Univ Fed Vale Sao Francisco, Colegiado Educ Fis, Petrolina, PE, Brazil
[3] Fac Assis Gurgacz, Cascavel, PR, Brazil
[4] Inst Fed Parana, Londrina, PR, Brazil
[5] Univ Ulster, Inst Nursing & Hlth Res, Sch Hlth Sci, Belfast, Antrim, North Ireland
[6] Univ Estadual Londrina, Sports Sci Dept, Londrina, PR, Brazil
[7] Univ Estadual Londrina, Univ Hosp, Aquat Phys Therapy Ctr Prof Paulo A Seibert, Londrina, PR, Brazil
关键词
Gait; Reliability; Kinetic; Hydrotherapy; Aquatic exercise; SHALLOW-WATER; KINEMATIC DATA; NORMAL WALKING; JOINT MOMENTS; GAIT EVENTS; IMMERSION; REHABILITATION; PARAMETERS; CONTACT; GENDER;
D O I
10.1016/j.jelekin.2016.05.002
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
The aim of this study was to verify the reliability of the kinetic parameters of gait using an underwater force platform. A total of 49 healthy participants with a median age of 21 years were included. The kinetic gait data were collected using a 0.6 x 0.6 x 0.1 m aquatic force plate (Bertec (R)), set in a pool (15 x 13 x 1.30 m) with a water depth of 1.20 m and water temperature of 32.5 degrees C. Participants walked 10 m before reaching the platform, which was fixed to the ground. Participants were instructed to step onto the platform with their preferred limb and data from three valid attempts were used to calculate the average values. A 48-h interval between tests was used for the test-retest reliability. Data were analyzed using interclass correlation coefficients (ICC) and results demonstrated that reliability ranged from poor to excellent, with ICC scores of between 0.24 and 0.87 and mean differences between ((d) over bar) = -0.01 and 0.002. The highest reliability values were found for the vertical (Fz) and the lowest for the mediolateral components (Fy). In conclusion, the force platform is reliable for assessing the vertical and anteroposterior components of power production rates in water, however, caution should be applied when using this instrument to evaluate the mediolateral component in this environment. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:23 / 30
页数:8
相关论文
共 47 条
[1]  
Amadio A. C., 2000, BRAZ J BIOMECH, V1, P7
[2]   Biomechanical characteristics of adults walking in shallow water and on land [J].
Barela, Ana M. F. ;
Stolf, Sandro F. ;
Duarte, Marcos .
JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2006, 16 (03) :250-256
[3]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]   Vertical reaction forces and kinematics of backward walking underwater [J].
Carneiro, Leticia Calado ;
Michaelsen, Stella Maris ;
Roesler, Helio ;
Haupenthal, Alessandro ;
Hubert, Marcel ;
Mallmann, Eddy .
GAIT & POSTURE, 2012, 35 (02) :225-230
[5]   A marker based kinematic method of identifying initial contact during gait suitable for use in real-time visual feedback applications [J].
De Asha, A. R. ;
Robinson, M. A. ;
Barton, G. J. .
GAIT & POSTURE, 2012, 36 (03) :650-652
[6]   Foot contact event detection using kinematic data in cerebral palsy children and normal adults gait [J].
Desailly, Eric ;
Daniel, Yepremian ;
Sardain, Philippe ;
Lacouture, Patrick .
GAIT & POSTURE, 2009, 29 (01) :76-80
[7]   The reliability of kinetic and kinematic variables used to analyse normal running gait [J].
Diss, CE .
GAIT & POSTURE, 2001, 14 (02) :98-103
[8]   Impact Forces of Plyometric Exercises Performed on Land and in Water [J].
Donoghue, Orna A. ;
Shimojo, Hirofumi ;
Takagi, Hideki .
SPORTS HEALTH-A MULTIDISCIPLINARY APPROACH, 2011, 3 (03) :303-309
[9]   Revision of posturography based on force plate for balance evaluation [J].
Duarte, Marcos ;
Freitas, Sandra M. S. F. .
BRAZILIAN JOURNAL OF PHYSICAL THERAPY, 2010, 14 (03) :183-192
[10]  
Fleiss J., 1986, Reliability of measurement: the design and analysis of clinical experiments