Open-loop control of cavity noise using Proper Orthogonal Decomposition reduced-order model

被引:15
作者
Nagarajan, Kaushik Kumar [1 ]
Singha, Sintu [1 ]
Cordier, Laurent [2 ]
Airiau, Christophe [3 ]
机构
[1] Natl Aerosp Labs, Bengaluru 560017, India
[2] Univ Poitiers, ISAE, CNRS, Inst Pprime,ENSMA, F-86962 Futuroscope, France
[3] Univ Toulouse, CNRS, INPT, IMFT,UPS,UMR 5502, 2 Allee Pr Camille Soula, F-31400 Toulouse, France
关键词
Open cavity flow; Optimal control; Noise reduction; Proper Orthogonal Decomposition; Reduced-order modeling; COMPRESSIBLE FLOW; POD; REDUCTION;
D O I
10.1016/j.compfluid.2017.10.019
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Flow over open cavities is mainly governed by a feedback mechanism due to the interaction of shear layer instabilities and acoustic forcing propagating upstream in the cavity. This phenomenon is known to lead to resonant tones that can reach 180 dB in the far-field and may cause structural fatigue issues and annoying noise emission. This paper concerns the use of optimal control theory for reducing the noise level emitted by the cavity. Boundary control is introduced at the cavity upstream corner as a normal velocity component. Model-based optimal control of cavity noise involves multiple simulations of the compressible Navier-Stokes equations and its adjoint, which makes it a computationally expensive optimization approach. To reduce the computational costs, we propose to use a reduced-order model (ROM) based on Proper Orthogonal Decomposition (POD) as a surrogate model of the forward simulation. For that, a control input separation method is first used to introduce explicitly the control effect in the model. Then, an accurate and robust POD ROM is derived by using an optimization-based identification procedure and generalized POD modes, respectively. Since the POD modes describe only velocities and speed of sound, we minimize a noise-related cost functional characteristic of the total enthalpy unsteadiness. After optimizing the control function with the reduced-order model, we verify the optimality of the solution using the original, high-fidelity model. A maximum noise reduction of 4.7 dB is reached in the cavity and up to 16 dB at the far-field. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1 / 13
页数:13
相关论文
共 35 条
[1]  
Airiau C, 2013, FLOW CONTROL 2 DIMEN
[2]  
[Anonymous], 2000, THESIS
[3]   A Survey of Projection-Based Model Reduction Methods for Parametric Dynamical Systems [J].
Benner, Peter ;
Gugercin, Serkan ;
Willcox, Karen .
SIAM REVIEW, 2015, 57 (04) :483-531
[4]   Optimal control of the cylinder wake in the laminar regime by trust-region methods and POD reduced-order models [J].
Bergmann, M. ;
Cordier, L. .
JOURNAL OF COMPUTATIONAL PHYSICS, 2008, 227 (16) :7813-7840
[5]   Optimal rotary control of the cylinder wake using proper orthogonal decomposition reduced-order model [J].
Bergmann, M ;
Cordier, L ;
Brancher, JP .
PHYSICS OF FLUIDS, 2005, 17 (09) :1-21
[6]   Three-dimensional instabilities in compressible flow over open cavities [J].
Bres, Guillaume A. ;
Colonius, Tim .
JOURNAL OF FLUID MECHANICS, 2008, 599 :309-339
[7]   Closed-Loop Turbulence Control: Progress and Challenges [J].
Brunton, Steven L. ;
Noack, Bernd R. .
APPLIED MECHANICS REVIEWS, 2015, 67 (05)
[8]   Calibration of POD reduced-order models using Tikhonov regularization [J].
Cordier, L. ;
Abou El Majd, B. ;
Favier, J. .
INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN FLUIDS, 2010, 63 (02) :269-296
[9]  
Cordier L., 2008, LECT SERIES 2002 04, P1
[10]  
Cordier L, 2011, CISM COURSES LECT, V528, P1