Contrast enhanced IR-SSFP examination compared with T1-weighted turbo spin-echo imaging of cardiac tumors and tumorlike lesions

被引:4
作者
Bauner, K. U. [1 ]
Sandner, T. [1 ]
Notohamiprodjo, M. [1 ]
Schmoeckel, M. [2 ]
Reiser, M. F. [1 ]
Huber, A. M. [1 ]
机构
[1] Univ Munich, Univ Hosp, Dept Clin Radiol, D-81377 Munich, Germany
[2] Univ Munich, Univ Hosp, Dept Cardiac Surg, D-81377 Munich, Germany
关键词
Cardiac; MRI; Delayed enhancement; Tumors; IR-SSFP; STATE FREE PRECESSION; MYOCARDIAL-INFARCTION; MAGNETIC-RESONANCE; EXPERIENCE; HEART;
D O I
10.1016/j.ejrad.2009.10.006
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To show that the use of an early and delayed contrast enhanced multislice inversion recovery steady state free precession (SS-IR-SSFP) is a valuable substitute for conventional post-contrast fat saturated turbo spin-echo (TSE) T1-weighted images in the assessment of cardiac tumors. Materials and methods: 34 consecutive patients referred for MRI in order to assess cardiac tumors were examined. Shortly after administration of gadopenetate dimeglumine (Gd-DTPA) images were obtained using a SS-IR-SSFP sequence. The inversion time (TI) was set at 350 ms to achieve a good demarcation of intracavitary tumor spread. Hereafter 9 slices of a T1w TSE sequence were obtained. Finally a SS-IR-SSFP sequence with an optimized TI to null normal myocardium was employed. Quantitative comparisons were performed by calculating contrast to noise ratios of tumor/myocardium (CNR(tumor/myo)) and CNR of tumor/left ventricular cavity (CNR(tumor/LVC)). Image quality was assessed regarding overall image quality, artifacts and tumor conspicuity. Results: Neither calculation of CNR(tumor/LVC) when comparing the early IR-SSFP and T1w TSE, nor calculation of CNR(tumor/myo) when comparing the late IR-SSFP and T1w TSE sequence resulted in statistically significant differences. However, qualitative assessments revealed significant superior results for the early and the late IR-SSFP images compared to the T1-weighted TSE images (p < 0.001). Conclusions: Image quality and tumor conspicuity were superior and image degradation by artifacts was less on IR-SSFP images compared to TSE images without loss of CNR. Thus the use of IR-SSFP sequences is an attractive alternative imaging method compared to post-contrast T1w TSE imaging in the assessment of cardiac tumors. (C) 2009 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:93 / 98
页数:6
相关论文
共 21 条
  • [1] Detection of myocarditis by contrast-enhanced MRI in patients presenting with acute coronary syndrome but no coronary stenosis
    Codreanu, Andrei
    Djaballah, Wassila
    Angioi, Michael
    Ethevenot, Gerard
    Moulin, Frederic
    Felblinger, Jacques
    Sadoul, Nicolas
    Karcher, Gilles
    Aliot, Etienne
    Marie, Pierre Y.
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 25 (05) : 957 - 964
  • [2] Using a contrast-enhanced imaging sequence at 3-minute delay in 3-T magnetic resonance imaging for acute infarct evaluation
    Comte, Alexandre
    Kastler, Bruno
    Laborie, Laurent
    Hadjidekov, Georges
    Meneveau, Nicolas
    Boulahdour, Hatem
    [J]. INVESTIGATIVE RADIOLOGY, 2008, 43 (09) : 669 - 675
  • [3] Gilkeson Robert C, 2003, Magn Reson Imaging Clin N Am, V11, P173, DOI 10.1016/S1064-9689(02)00047-8
  • [4] From the archives of the AFIP - Cardiac myxoma: Imaging features in 83 patients
    Grebenc, ML
    Rosado-de-Christenson, ML
    Green, CE
    Burke, AP
    Galvin, JR
    [J]. RADIOGRAPHICS, 2002, 22 (03) : 673 - 689
  • [5] Myocardial infarction: Optimization of inversion times at delayed contrast-enhanced MR imaging
    Gupta, A
    Lee, VS
    Chung, YC
    Babb, JS
    Simonetti, OP
    [J]. RADIOLOGY, 2004, 233 (03) : 921 - 926
  • [6] Single-shot inversion recovery trueFISP for assessment of myocardial infarction
    Huber, A
    Schoenberg, SO
    Spannag, B
    Rieber, J
    Erhard, I
    Klauss, V
    Reiser, MF
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2006, 186 (03) : 627 - 633
  • [7] Phase-sensitive inversion recovery single-shot balanced steady-state free precession for detection of myocardial infarction during a single breathhold
    Huber, Armin
    Hayes, Carmel
    Spannagl, Benedikt
    Rieber, Johannes
    Klauss, Volker
    Schoenberg, Stefan Oswald
    Reiser, Maximilion
    Wintersperger, Bernd Jurgen
    [J]. ACADEMIC RADIOLOGY, 2007, 14 (12) : 1500 - 1508
  • [8] KIRICUTA IC, 1975, CANCER RES, V35, P1164
  • [9] Value of contrast-enhanced, balanced cine-MR sequences in the assessment of apparent infarct size after acute myocardial infarction: A prospective comparison with delayed-enhancement sequences
    Laissy, JP
    Hyafil, F
    Huart, V
    Serfaty, JM
    Chillon, S
    Schouman-Claeys, E
    Faraggi, M
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 22 (06) : 765 - 771
  • [10] LAM KY, 1993, ARCH PATHOL LAB MED, V117, P1027