Position and time sensitive photon counting detector with image charge delay-line readout

被引:5
|
作者
Czasch, Achim [1 ]
Dangendorf, Volker
Milnes, James
Schoessler, Sven [1 ]
Lauck, Ronald
Spillmann, Uwe
Howorth, Jon
Jagutzki, Ottmar [1 ]
机构
[1] Goethe Univ Frankfurt, Inst Kernphys, Max von Laue Str 1, D-60438 Frankfurt, Germany
来源
关键词
photo-multiplier tube; MCP; image intensifier; delay-line; photon counting; 3d imaging; X-ray polarimetry; fast-neutron radiography; homeland security; scintillator read-out;
D O I
10.1117/12.736935
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
We have developed single photon counting image intensifier tubes combining position and time information read-out with at least 500x500 pixels and sub-nanosecond time resolution. This image intensifier type uses a resistive screen instead of a phosphor screen and the image charge pickup anode is placed outside the sealed tube. We present a novel delay-line anode design which allows for instance detecting simultaneously arriving pairs of photons. Due to the very low background this technique is suited for applications with very low light intensity and especially if a precise time tagging for each photon is required. We show results obtained with several anode types on a 25 mm image intensifier tube and a 40 mm open-face MCP detector and discuss the performance in neutron radiography, e.g. for homeland security, and the prospects for applications like Fluorescence Life-time Imaging Microscopy (FLIM), astronomy and X-ray polarimetry.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Position- and time-sensitive single photon detector with delay-line readout
    Czasch, A.
    Milnes, J.
    Hay, N.
    Wicking, W.
    Jagutzki, O.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 580 (02): : 1066 - 1070
  • [2] A position- and time-sensitive photon-counting detector with delay-line read-out
    Jagutzki, Ottmar
    Dangendorf, Volker
    Lauck, Ronald
    Czasch, Achim
    Milnes, James
    OPTICAL SENSING TECHNOLOGY AND APPLICATIONS, 2007, 6585
  • [3] A POSITION-SENSITIVE MICROCHANNELPLATE DETECTOR USING A DELAY-LINE READOUT ANODE
    KELLER, H
    KLINGELHOFER, G
    KANKELEIT, E
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1987, 258 (02): : 221 - 224
  • [4] Study of Ultraviolet Photon Counting Detector with Delay-Line Anode
    Lei Fan-pu
    Zhu Bing-li
    Bai Xiao-hong
    Qin Jun-jun
    Xu Peng
    Hou Xun
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37 (10) : 2989 - 2994
  • [5] A MICROSTRIP DETECTOR WITH DELAY-LINE READOUT
    BARBOSA, AF
    RIEKEL, C
    WATTECAMPS, P
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (01): : 667 - 669
  • [6] Study of delay-line readout for GEM detector
    Zhou, Yi
    Li, Cheng
    Sun, Yongjie
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 604 (1-2): : 71 - 76
  • [7] Design of a delay-line position-sensitive detector with improved performance
    Da Costa, G
    Vurpillot, F
    Bostel, A
    Bouet, M
    Deconihout, B
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2005, 76 (01):
  • [8] High Resolution Electronics for a Position Sensitive MCP Delay-line Detector
    Dong, Wenhao
    Feng, Changqing
    Shi, Yufeng
    Song, Xiaolin
    Liu, Shubin
    2019 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2019,
  • [9] LOW-DEAD-TIME DELAY-LINE READOUT FOR POSITION-SENSITIVE PROPORTIONAL-COUNTERS
    ANDERSON, AN
    BARRETT, RJ
    WADLINGER, EA
    NUCLEAR INSTRUMENTS & METHODS, 1974, 119 (02): : 365 - 366
  • [10] DELAY-LINE READOUT OF MICROCHANNEL PLATES IN A PROTOTYPE POSITION-SENSITIVE PHOTOMULTIPLIER TUBE
    WILLIAMS, MB
    SOBOTTKA, SE
    SHEPHERD, JA
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 302 (01): : 105 - 112