Optimized lighting energy consumption for non-visual effects: A case study in office spaces based on field test and simulation

被引:22
作者
Zeng, Yunyi [2 ,3 ]
Sun, Hongli [1 ,3 ]
Lin, Borong [2 ,3 ]
机构
[1] Sichuan Univ, Coll Architecture & Environm, Chengdu 610065, Peoples R China
[2] Tsinghua Univ, Dept Bldg Sci, Beijing 100084, Peoples R China
[3] Tsinghua Univ, Minist Educ, Key Lab Eco Planning & Green Bldg, Beijing, Peoples R China
基金
中国国家自然科学基金; 美国国家科学基金会;
关键词
Light environment; Non-visual effects; Lighting control; Daylight harvesting; Energy consumption; ACTION SPECTRUM; CONTROL-SYSTEMS; DAYLIGHT; DESIGN; PERFORMANCE; SAVINGS; ILLUMINANCE; VALIDATION; EFFICIENCY; ALERTNESS;
D O I
10.1016/j.buildenv.2021.108238
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Recently, the non-visual effects of the light environment have received increasing attention. Some standards have proposed evaluation metrics for non-visual effects in office spaces to ensure the health and well-being of occupants. Non-visual metrics are new requirements for indoor light environments, whose impacts on lighting adjustment and ultimate lighting energy performance are currently unknown. Therefore, this study aimed to present a workflow to obtain optimal light outputs considering non-visual lighting requirements, in addition to traditional visual requirements. This workflow was implemented to calculate the annual lighting energy consumption under different light correlated color temperatures (CCTs), daylight conditions, and standard requirements for an actual office scenario. As deduced from the results, adding non-visual requirements may significantly increase the lighting energy consumption by 57 %. Furthermore, daylight and light with a higher CCT are beneficial for non-visual energy-saving. The additional non-visual requirements will not increase the lighting energy consumption under favorable daylight conditions. The 5500 K light can save up to 20 % of the annual lighting power consumption than the 4000 K light. The presented workflow and conclusions contribute to engineering office environments with enhanced lighting, better circadian stimulus, and improved office lighting energy efficiency.
引用
收藏
页数:16
相关论文
共 46 条
[1]   Daylighting design for healthy environments: Analysis of educational spaces for optimal circadian stimulus [J].
Acosta, Ignacio ;
Angel Campano, Miguel ;
Leslie, Russell ;
Radetsky, Leora .
SOLAR ENERGY, 2019, 193 :584-596
[2]   Analysis of the performance of domestic lighting lamps [J].
Aman, M. M. ;
Jasmon, G. B. ;
Mokhlis, H. ;
Bakar, A. H. A. .
ENERGY POLICY, 2013, 52 :482-500
[3]   A framework for predicting the non-visual effects of daylight - Part I: photobiology-based model [J].
Andersen, M. ;
Mardaljevic, J. ;
Lockley, S. W. .
LIGHTING RESEARCH & TECHNOLOGY, 2012, 44 (01) :37-53
[4]   Modelling 'non-visual' effects of daylighting in a residential environment [J].
Andersen, Marilyne ;
Gochenour, Sharon J. ;
Lockley, Steven W. .
BUILDING AND ENVIRONMENT, 2013, 70 :138-149
[5]  
[Anonymous], 2014, MEASURING MELANOPIC
[6]   Controlling light-dark exposure patterns rather than sleep schedules determines circadian phase [J].
Appleman, Kenneth ;
Figueiro, Mariana G. ;
Rea, Mark S. .
SLEEP MEDICINE, 2013, 14 (05) :456-461
[7]  
Assessment Standard for Healthy building, 2016, 022016 TASC
[8]   Winter and summer analysis of daylight characteristics in offices [J].
Bellia, Laura ;
Pedace, Alessia ;
Barbato, Giuseppe .
BUILDING AND ENVIRONMENT, 2014, 81 :150-161
[9]   Daylighting offices: A first step toward an analysis of photobiological effects for design practice purposes [J].
Bellia, Laura ;
Pedace, Alessia ;
Barbato, Giuseppe .
BUILDING AND ENVIRONMENT, 2014, 74 :54-64
[10]   Phototransduction by retinal ganglion cells that set the circadian clock [J].
Berson, DM ;
Dunn, FA ;
Takao, M .
SCIENCE, 2002, 295 (5557) :1070-1073