Analytical study of critical heat flux in two-phase thermosyphon: Relationship between maximum falling liquid rate and critical heat flux

被引:11
作者
Monde, M
机构
[1] Department of Mechanical Engineering, Saga University
来源
JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME | 1996年 / 118卷 / 02期
关键词
D O I
10.1115/1.2825861
中图分类号
O414.1 [热力学];
学科分类号
摘要
An analytical study has been done on the critical heat flux of a two-phase thermosyphon, in which a liquid film and a vapor flow exist in a countercurrent annular flow. The CHF point on the thermosyphon is proved to correspond to a maximum falling liquid rate fed to the thermosyphon, which can be determined from three equations of momentum, its partial derivative with void fraction, and mass balance in the thermosyphon. This maximum point, furthermore, becomes identical to the point at which an envelope line generated from the momentum equation and its partial derivative intersects the mass balance line. The CHF calculated from the maximum liquid rare is found to be in fairly good agreement with the existing CHF data.
引用
收藏
页码:422 / 428
页数:7
相关论文
共 27 条
[1]   ASYMPTOTIC SOLUTION TO FALLING FILM STABILITY PROBLEM [J].
ANSHUS, BE .
INDUSTRIAL & ENGINEERING CHEMISTRY FUNDAMENTALS, 1972, 11 (04) :502-&
[2]   AIR WATER COUNTERCURRENT ANNULAR-FLOW [J].
BHARATHAN, D ;
WALLIS, GB .
INTERNATIONAL JOURNAL OF MULTIPHASE FLOW, 1983, 9 (04) :349-366
[3]  
Bharathan D., 1979, NP1165 EPRI
[4]   INFLUENCE OF MASS-TRANSFER ON THE MOMENTUM-TRANSFER IN CONDENSATION AND EVAPORATION PHENOMENA [J].
BLANGETTI, F ;
NAUSHAHI, MK .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1980, 23 (12) :1694-1695
[5]  
DOBRAN F, 1981, ASME HTD, V15
[6]   CRITICAL HEAT-FLUX IN A CLOSED 2-PHASE THERMOSYPHON [J].
IMURA, H ;
SASAGUCHI, K ;
KOZAI, H ;
NUMATA, S .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1983, 26 (08) :1181-1188
[7]   FLOODING VELOCITY IN A COUNTERCURRENT ANNULAR 2-PHASE FLOW [J].
IMURA, H ;
KUSUDA, H ;
FUNATSU, S .
CHEMICAL ENGINEERING SCIENCE, 1977, 32 (01) :79-87
[8]   LIMIT CONDITIONS OF STEADY-STATE COUNTERCURRENT ANNULAR-FLOW AND THE ONSET OF FLOODING, WITH REFERENCE TO THE CHF OF BOILING IN A BOTTOM-CLOSED VERTICAL TUBE [J].
KATTO, Y .
INTERNATIONAL JOURNAL OF MULTIPHASE FLOW, 1994, 20 (01) :45-61
[9]   AN ANALYTICAL STUDY ON THE CRITICAL HEAT-FLUX OF COUNTERCURRENT BOILING IN A VERTICAL TUBE WITH A CLOSED BOTTOM [J].
KATTO, Y ;
WATANABE, K .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1992, 35 (11) :3021-3028
[10]  
KUSUDA H, 1974, T JSME, V40, P1082